Samsung RF31FM Series Manual page 173

French door refrigerator
Hide thumbs Also See for RF31FM Series:
Table of Contents

Advertisement

https://appliancetechmanuals.com
6. Self Diagnosis & Trouble Shooting
6-1. If the trouble is detected by self-diagnosis
8) If PANTRY Sensor has trouble
ERROR Code
DATA1. Temperature table
** Measuring point of resistance value
according to Sensor **
Flex : CN30#9 ↔ CN76 #1 measuring
resistance value
** 0Ω: Short trouble / ∞Ω: Open trouble
Refer to circuit diagram in the manual
Sensor MICOM/Connector number
Connector CN30-"9"(Yellow)
Mid
to J23 JUMMPER PCB
drawer
typical Ground
Voltage measured between 4.6V ~ 0.6V.
Start
Is MAIN PCB
Connector CN30 and CN76 insert
correctly?
YES
Is Mid drawer Sensor
normal?
YES
Is the voltage between
MAIN PCB Connector
CN30-"9"(Yellow) and
J23 JUMMPER normal?
YES
NO
Bad contact of connector/
insert correctly
NO
Replace temperature sensor
NO
(0.6V > Measurement < 4.6V)
Recheck the wiring
connection
To do list