MICROWAVE/ WALL OVEN COMBINATION
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
Your new wall oven has been designed to fit a limited variety of cutout sizes to make the
job of installing easier. The first step of your installation should be to measure your current
cutout dimensions and compare them to the cutout dimensions chart below for your
model. You may find little or no cabinet work is necessary.
Do not remove spacers (if equipped) on the side walls and/or on the back of the built-
in oven. These spacers center the oven in the space provided. The oven must be centered to prevent
excess heat buildup that may result in heat damage or fire.
NOTES:
1. Base must be capable of supporting 225 pounds (102 kg).
2. Allow at least 21" (53.3cm) clearance in front of oven for door
depth when it is open.
3. Dimension G (cutout depth) is
critical to the proper installation
of the built-in oven. If the
oven decorative trim does not
butt against the cabinet verify
dimension G to assure it is the
required depth.
* Suggested distance from floor
is 11½" (29.2cm).
Minimum required distance is
4 ½" (11.4cm)
MODEL
27" (68.6cm) Wall Oven
30" (76.2cm) Wall Oven
MODEL
27" (68.6cm) Wall Oven
30" (76.2cm) Wall Oven
All dimensions are stated in inches and (cm).
Printed in United States
INSTALLATION INSTRUCTIONS
B
Door Open
(see note 2)
A
PRODUCT DIMENSIONS
A
27 (68.6)
30 (76.2)
CUTOUT DIMENSIONS AND CABINET WIDTH
F
Min.
Max.
24
/
(63.2)
25¼ (64.1)
7
8
28½ (72.4)
29 (73.7)
1" (2.5 cm)
Min.
C
H
40-15/16"
(104 cm)
11½"
(29.2 cm)
Spacer
D
2" (5 cm) Wide Wood
Spacer if Needed
Figure 1
B
42¾ (108.6)
24
42¾ (108.6)
28¼ (71.8)
G. Min.
Min.
23½ (59.7)
41
/
(104.5)
1
8
23½ (59.7)
41
/
(104.5)
1
8
1
Canada
United States
Hole for
Cable
I
(right or
left side
depending
on model)
G
F
3" (7.6 cm)
1¼"
(3.2 cm)
Junction Box
Min.
(right or left side)
C
D
/
(62.5)
24½ (62.2)
5
8
24½ (62.2)
H
Max.
I
41¼ (104.8)
27
/
(68.9) Min
1
8
41¼ (104.8)
30
/
(76.5) Min
1
8
P/N 318201534 (0905) Rev. A
Max.
Electrical

Advertisement

Table of Contents
loading

Summary of Contents for Frigidaire 318201534

  • Page 1 Spacer if Needed (62.5) 24½ (62.2) 28¼ (71.8) 24½ (62.2) Min. Max. (104.5) 41¼ (104.8) (68.9) Min (104.5) 41¼ (104.8) (76.5) Min P/N 318201534 (0905) Rev. A Hole for Cable (right or left side depending on model) 3” (7.6 cm) Max. Electrical...
  • Page 2: Important Safety Instructions

    MICROWAVE/ WALL OVEN COMBINATION INSTALLATION INSTRUCTIONS Important Notes to the Installer 1. Read all instructions contained in these installation instructions before installing the combination oven. 2. Remove all packing material from the oven compartments before connecting the electrical supply to the wall oven. 3.
  • Page 3: Electrical Shock Hazard

    MICROWAVE/ WALL OVEN COMBINATION INSTALLATION INSTRUCTIONS Electrical Shock Hazard • Electrical ground is required on this appliance. • Do not connect to the electrical supply until appliance is permanently grounded. • Disconnect power to the junction box before making the electrical connection. •...
  • Page 4: Cabinet Installation

    MICROWAVE/ WALL OVEN COMBINATION INSTALLATION INSTRUCTIONS If oven is used in a new branch circuit installation (1996 NEC), mobile home, recreational vehicle, or where local codes DO NOT permit grounding through the neutral (white) wire, the appliance frame MUST NOT be connected to the neutral wire of the 4-wire electrical system.
  • Page 5 MICROWAVE/ WALL OVEN COMBINATION INSTALLATION INSTRUCTIONS Install the Anti-tip Mounting Screws The wall oven can tip when the door is open. The anti-tip mounting screws supplied with the wall oven must be installed to prevent tipping of the wall oven and injury to persons. A.
  • Page 6: Checking Operation

    MICROWAVE/ WALL OVEN COMBINATION INSTALLATION INSTRUCTIONS 5. Leveling the Wall Oven 1. Install an oven rack in the center of the upper oven (see Figure 8). 2. Place a level on the rack. Take 2 readings with the level placed diagonally in one direction and then the other.
  • Page 7 24½ (62.2) 28¼ (71.8) 24½ (62.2) Min. Max. (104.5) 41¼ (104.8) (68.9) Min (104.5) 41¼ (104.8) (76.5) Min P/N 318201534 (0905) Rev. A Ouverture pour la sortie du câble (à droite ou à gauche selon le modèle) 3” (7.6 cm) Max.
  • Page 8: Directives Importantes De Sécurité

    INSTRUCTIONS D'INSTALLATION POUR LE MODÈLE COMBINÉ FOUR À ENCASTRER/FOUR À MICRO-ONDES Notes importantes pour l'installateur 1. Lisez toutes les instructions contenues dans ce feuillet avant l’installation du four encastré. 2. Enlevez tout le matériel d’emballage du four avant de procéder au raccordement électrique. 3.
  • Page 9: Risque De Choc Électrique

    INSTRUCTIONS D'INSTALLATION POUR LE MODÈLE COMBINÉ FOUR À ENCASTRER/FOUR À MICRO-ONDES Risque de choc électrique • La mise à la terre de cet appareil est obligatoire. • Ne branchez pas l’appareil au circuit électrique tant qu’il ne sera pas mis à la terre correctement et en permanence.
  • Page 10 INSTRUCTIONS D'INSTALLATION POUR LE MODÈLE COMBINÉ FOUR À ENCASTRER/FOUR À MICRO-ONDES Si l’appareil est utilisé dans une maison mobile, un nouveau branchement (1996 NEC), un véhicule récréatif ou si les codes locaux N'AUTORISENT PAS la connexion du conducteur de mise à la terre du châssis au neutre, le châssis de l'appareil NE DOIT PAS être branché...
  • Page 11 INSTRUCTIONS D'INSTALLATION POUR LE MODÈLE COMBINÉ FOUR À ENCASTRER/FOUR À MICRO-ONDES Installez les vis de fixation Le four encastré peut basculer quand la porte est ouverte. Il faut fixer l'appareil à l'armoire, à l'aide des vis de fixation fournis, pour prévenir le basculement du four et des blessures corporelles.
  • Page 12: Vérification Du Fonctionnement

    INSTRUCTIONS D'INSTALLATION POUR LE MODÈLE COMBINÉ FOUR À ENCASTRER/FOUR À MICRO-ONDES 5. Mise à niveau du four encastré 1. Installez une grille au centre du four supérieur ( Voir la figure 8). 2. Déposez un niveau à bulle sur la grille. Prenez 2 lectures en plaçant le niveau en diagonale dans une direction, puis dans l’autre direction.

This manual is also suitable for:

Cpmc3085kf

Table of Contents