Hose & Regulator Assembly And Replacement - Allen + Roth FHWS80079-1 Manual

A+r southland firepit
Table of Contents

Advertisement

Available languages

Available languages

HOSE & REGULATOR ASSEMBLY AND REPLACEMENT
1. This fire table comes equipped with a standard LP gas hose and regulator including the appliance side connection for a CGA
No 791 Cylinder Connection Device. The LP gas hose and regulator supplied with this fire table must be used. Only a hose
and regulator specified by manufacturer can be used for replacement.
a. The CGA No 791 connection incorporates a magnetic flow limiting device that acts to limit the flow of gas if a leak is
detected between the regulator and the burner valves.
b. If the burner valve is open prior to the LP gas cylinder service valve being opened. The connection will interpret this
free flow of gas to be a leak.
c. The connection safety feature will reduce gas flow from the regulator to the appliance to a minimal level.
d. Be sure that the burner control valve is closed prior to opening the LP gas cylinder service valve to ensure that the
connection flow limiting device is not triggered mistakenly.
e. If the connection flow limiting device is triggered mistakenly, close the LP gas cylinder service valve and the burner valve,
wait 10 seconds to allow the device to reset, open the cylinder service valve, then open the burner valve and light the
firepit as per lighting instructions.
2. Be sure to protect the hose from any hot surfaces. Serious danger may result if the hose contacts any hot surface.
3. Regular maintenance of the hose and regulator:
a. Inspect the hose before each use of the fire table. If the hose shows signs of cracks, abrasions, cuts or damage of any
kind, do not operate the appliance. Fix or replace the hose as required before using the appliance, For assistance with
repair or replacement of the hose, call our customer service department at 1-866-439-9800. Use only replacement parts
from the manufacturer.
b. Inspect the seal inside the CGA No 791 service valve on the LP gas cylinder when replacing the cylinder or at least
once per year. If there is any indication of damage, have the seal replaced by a certified gas dealer before operating
the appliance.
4. Do not use tools to tighten the CGA No 791 connection nut onto the LP gas cylinder service valve. Hand tighten only.
5. Be careful to not cross the threads on the connection when tightening the CGA No 791 connection on to the LP gas
cylinder service valve.
6. " Leak Test " should always be performed after attaching the connection to the LP gas cylinder service valve. (See
" Checking for Leaks" section of this manual on page 14).
7. For the connection of the hose and regulator to the LP tank, refer to the " Connection " section of the LP gas cylinder
section above.
Glass beads warning:
1. Glass media may have sharp edges. Wear safety glasses and gloves when handing.
2. Do not change or substitute the glass media material provided with this fire pit, If replacing, use only replacement
glass media available from your local authorized dealer/distributor.
3. Pour the glass media evenly in to the burner area (with the exception of the screen- if applicable). The glass should
be 1/2 " above the burner.
4.
Do not exceed a height of 1" above the burner when placing glass media. Ensure no media covers
IMPORTANT:
the igniter screen. store any excess media in a safe location.
5. Keep away from the unit for the first 20 minutes after igniting your unit for the first time, as glass beads could pop
out and cause injury. Should any glass beads pop out, discard them.
6. Always ensure that glass beads are completely dry before use.
Failure to do so will cause them to crack or pop.
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

4143697

Table of Contents