Epson RX-8564LC Applications Manual page 27

Real time clock module
Table of Contents

Advertisement

RX
8564 LC
13.2.4.2. Operation example of repeated interrupt mode ( TI / TP = " 1 " )
After an interrupt event has occurred, execution of the operation is automatically repeated continuously.
Fixed-cycle timer operation
starts
(1)
TE bit
TIE bit
/INT output
TF bit
Event
(1)
occurs
The fixed-cycle timer function (countdown) starts when the TE bit value is changed from "0" to "1".
Before starting the fixed-cycle timer interrupt function each time, be sure to write a value (preset
value/Reg-0F[h]) as the timer's down counter value (when TE = "0").
RTC's internal operation
Write operation
Before starting the fixed-cycle timer interrupt function each time, be sure to write a value (preset value/Reg-0F[h])
as the timer's down counter value (when TE = "0").
(Note) Note with caution that the preset value must be set or reset to enable correct operation.
Before entering operation settings, we recommend first clearing the TE bit to "0" and then clearing the TF and TIE
bits to "0" in that order, so that all control-related bits are zero-cleared (= set to operation stop mode) to prevent
hardware interrupts from occurring inadvertently while entering settings.
(1) When the TE bit value is changed from "0" to 1", the fixed-cycle timer's countdown begins.
(2) A fixed-cycle timer interrupt event starts a countdown based on the countdown period (source clock). When the
count value changes from 01h to 00h, an interrupt event occurs.
After the interrupt event that occurs when the count value changes from 01h to 00h, the counter
automatically reloads the preset value and again starts to count down. (Repeated operation)
(3) When a fixed-cycle timer interrupt event occurs, "1" is written to the TF bit.
(4) When the TF bit = "1" its value is retained until it is cleared to zero.
( 11 ) Even when the TE bit is cleared to zero, the TF bit value is retained as "1" and the /TIRQ pin status is
not reset.
(5) If the TIE bit = "1" when a fixed-cycle timer interrupt occurs, /INT pin output goes low.
( 9 ) If the TIE bit = "0" when a fixed-cycle timer interrupt occurs, /INT pin output remains Hi-Z.
(6) Output from the /INT pin remains low during the tRTN period following each event, after which it is automatically
cleared to Hi-Z status.
(7) When the next interrupt event occurs, the /INT is again set to low level ("L").
(4) In this operation example, the TF bit is not cleared to zero, so the "1" value is held.
(8) When /INT is at low level ("L"), it remains at low level during the tRTN period, even if the TF bit value is changed
from "1" to "0".
(10) Changing the TE bit value from "1" to 0" stops the fixed-cycle timer's function (stops the countdown).
Fixed-cycle timer operation in progress
" 1 "
(5)
(6)
tRTN
(4)
(3)
1st period
2nd period
(2)
01 h
00 h
Page
(9)
tRTN
tRTN
(8)
Low level is held during
tRTN, even if the TF bit is
cleared to zero.
3rd period
(7)
24
Fixed-cycle timer operation
stops
(10)
(11)
TF bit value is held as "1"
even if the TE bit is cleared to
zero.
(10)
As long as the TE bit value
is "0", the countdown is
stopped and no events occur.
ETM12E-01
" 1 "
" 0 "
" 1 "
" 0 "
Hi - z
" L "
" 1 "
" 0 "