Diagrams; Wiring Diagram - Lochinvar Knight XL 100 Series Installation & Operation Manual

Hide thumbs Also See for Knight XL 100 Series:
Table of Contents

Advertisement

SHIELD
+
35
BMS
0-10V
-
36
IN
+
37
SYS PUMP
0-10V
IN
-
38
BLR PUMP
+
39
0-10V
OUT
-
40
+
41
RATE
0-10V
14
OUT
-
42

Diagrams

43
SHIELD
44
A
MODBUS
45
B
46
SHIELD
Figure 14-1 Wiring Diagram
LOW VOLTAGE
120 VAC
HIGH VOLTAGE
BOX DEPICTS
OPTIONAL ITEMS
BOX DEPICTS
DUAL SENSOR
SINGLE HOUSING
ALARM
CONTACTS
RUN-TIME
CONTACTS
24 VAC RECIRC
PUMP RELAY COIL
24 VAC LOUVER
RELAY COIL
LOUVER
PROVING SWITCH
GA
S PRESSURE
SWITCH
FLOW
SWITCH
INLET
TANK
SENSOR
THERMOSTAT
HEAT/LOOP
3
OUTLET SENSOR:
1
OPERATING
DEMAND
HEAT/LOOP
2
OUTLET SENSOR:
HIGH LIMIT
DEMAND
2
HEAT/LOOP
1
FLUE
SENSOR
DEMAND
6
FLUE
SENSOR
13
CONNECTION
BOARD
SYSTEM
SENSOR
1
ALARM
OUTDOOR
CONTACTS
SENSOR
2
DHW RECIRC
SE N SOR
3
RUN-TIME
CONTACTS
TANK
4
SENSOR
SHIELD
23
SYSTEM
A
24
CASCADE
SENSOR
B
25
OUTDOOR
SHIELD
SENSOR
26
DHW RECIRC
27
SE N SOR
28
29
TANK
+
30
SENSOR
BMS
0-10V
-
IN
31
SHIELD
+
32
SYS PUMP
A
CASCADE
0-10V
-
IN
33
B
+
34
BLR PUMP
SHIELD
0-10V
-
OUT
+
BMS
35
0-10V
+
RATE
-
36
IN
0-10V
-
OUT
+
SYS PUMP
37
SHIELD
0-10V
IN
-
38
MODBUS
A
BLR PUMP
+
OPTION
39
B
0-10V
OUT
-
40
SHIELD
+
41
RATE
0-10V
LOW
24 VAC
OUT
-
42
COM
WATER
43
SHIELD
CUT-OFF
44
A
MODBUS
45
B
46
SHIELD
SHIELD
GROUNDING
JUMPER
Notes:
1. All wiring must be installed with local, state, provincial, and national code requirements per either N.E.C. in USA or C.S.A. in Canada.
2. If any original equipment wire as supplied with appliance must be replaced, then it must be replaced with wire having same wire gauge (AWG) and rated for a minumum of 105°C. Exceptions: Replacement high voltage
spark lead and ribbon cables must be purchased from the factory. Use of a non-approved spark lead or ribbon cables can lead to operational problems which could result in non-repairable damage to the integrated controller
or other components.
3. Actual connector block locations may vary from those shown on diagrams. Refer to actual components for proper connector block locations when using diagrams to trouble shoot.
4. Where possible, switches are shown without utilities (gas, water, electricity) connected to the unit. As such, actual switch states may vary from those shown on diagrams depending upon whether utilities are connected or
fault condition is persent.
78
ALARM
CONTACTS
RUN-TIME
CONTACTS
CN6
X6
CN6
X6
CN6
X6
CN6
X6
CN6
X6
CN6
X6
CN6
X6
X7
M
O
CN8-1
X6-1
X4-1
X9-2
D
B
CN8-2
X6-2
X4-2
X9-1
U
X4-3
X9-3
CN8-3
X6-3
S
120VAC
TERMINAL STRIP
120V SUPPLY "L"
ON / OFF
INTEGRATED CONTROL
SWITCH
X1-6
F2
3.15A
F1
6.3
A
CONNECTION BOARD
F3
.8A
1
X5-9
2
120 VAC
3
4
X4-3
5
3A
24 VAC
6
7
CN5-1
BK
8
CN5-9
BK
CN5-5
9
BK
CN5-2
10
BK
CN5-10
INTEGRATED
11
CN5-16
CONTROL
12
CN5-11
BK
CN5-3
BK
BK
CN5-5
BK
13
CN5-4
BK
14
CN5-12
X5-6
S2
15
CN5-15
BK
16
CN5-13
BK
X5-4
S1a
BK
17
CN5-6
BK
18
CN5-14
X5-12
S1b
BK
19
CN5-7
20
X5-5
S3a
21
22
X5-13
S3b
X5-14
23
24
CN5-1
X4-7
25
26
CN5-9
X4-14
27
28
CN5-2
X4-6
29
CN5-10
X4-13
30
31
CN6
X6
32
CN6
X6
33
CN6
X6
34
CN6
CN6
X6
CN6
X6
CN6
X6
35
36
CN6
X6
37
CN6
X6
38
CN6
X6
39
CN6
40
X6
41
CN6
X6
42
CN6
X6
43
CN6
X6
44
CN6
X6
45
CN6
X6
46
CN6
X6
X7
CN7-1
CN7-2
M
CN7-3
O
CN7-4
CN8-1
X6-1
X4-1
X9-2
D
X6-2
B
CN8-2
X4-2
X9-1
R
BL
G
U
X4-3
X9-3
CN8-3
X6-3
S
X4-1
X4-2
X4-3
MODBUS BOARD
X4-4
MTR-01
X5-1
X5-2
X1-1
X1-2
X1-3
CONNECTION BOARD
1
2
3
4
COMMUNICATION
CONTROL BOARD
J3 J11
SW1
J9B
J9A
OPTIONAL USB/WIFI
EXTENSION CABLE
J2
J4
J12
OPTIONAL
ETHERNET CABLE
24V
E
GND
SHIELDED RIBBON CABLE
JUNCTION BOX
NEUTRAL
TERMINAL STRIP
120V SUPPLY "N"
1
2
BLOWER
RELAY
BLOWER
3
X1-1
BLOWER
RELAY
X1-2
LCD
SYSTEM PUMP
SYSTEM PUMP
RELAY
DISPLAY
RELAY
WIFI
X1-3
DONGLE
DHW PUMP
DHW PUMP
RELAY
RELAY
COMMUNICATION
X1-4
CONTROL BOARD
J3 J11
BOILER PUMP
BOILER PUMP
J8
RELAY
RELAY
J9B
J9A
24V DC
OPTIONAL USB/WIFI
EXTENSION CABLE
SUPPLY
J2
J4
X5-1
J12
OPTIONAL
ETHERNET CABLE
24V
E
GND
SHIELDED CABLE
LWCO
CN7-3
24 VAC
CN7-1
1
HEAT/LOOP
DEMAND
21
2
HEAT/LOOP
DEMAND
DAMPER
FLUE DAMPER
RELAY
19
3
HEAT/LOOP
1
DEMAND
M
2
17
3
TANK
THERMOSTAT
15
LOW GAS
HIGH GAS
PRESSURE
PRESSURE
SWITCH
SWITCH
11
LCD
DISPLAY
COMMUNICATION
CONTROL BOARD
J3 J11
SW1
J9B
J9A
OPTIONAL USB/WIFI
EXTENSION CABLE
J2
J4
J12
OPTIONAL
ETHERNET CABLE
24V
E
GND
SHIELDED RIBBON CABLE
O
GY
G
BK
W
G
LCD
DISPLAY
WIFI
DONGLE
COMMUNICATION
CONTROL BOARD
J3 J11
J8
J9B
J9A
OPTIONAL USB/WIFI
EXTENSION CABLE
J2
J4
J12
OPTIONAL
ETHERNET CABLE
24V
E
LOUVER
WIFI
9
PROVING SWITCH
DONGLE
10
Installation & Operation Manual
BLOCKED
DRAIN SWITCH
AIR PRESSURE
SWITCH
GAS VALVE
BLOWER
L
IN
GROUND
SYSTEM
PUMP
CONTACTS
BOILER
PUMP
CONTACTS
SPARK
ROD
DHW
CAUTION
HIGH VOLTAGE SPARK LEAD
PUMP
CONTACTS
INTEGRATED
CONTROL
PUMP RELAYS
X-7
PUMP RELAYS
OR
X1-3
CN2-4
CN1-5
K1
CN1-6
CONNECTION BOARD
BR
X1-4
CN1-3
CN2-2
K2
X4-7
CN1-4
X4-14
X1-2
PR
FLOW
CN2-3
CN1-1
X4-6
K3
X4-13
CN2-1
CN1-2
CN7-4
SWITCH
13
14
X4-5
ON/OFF
X4-12
SWITCH
CN7-2
X4-11
X1-6
BK
X4-4
X1-5
W
X4-3
X4-8
X4-10
X4-2
22
X1-8
G
X4-9
X4-1
X1-1
R
20
FAN
RELAY
18
R W
G
1 2
3
16
BLOWER
1 2 3 4 5
9
12
X5-3
X5-7
R
RECIRC PUMP
5
T
X5-16
RELAY COIL
X6
X5-8
W
24VAC
6
BK
X5-15
LOUVER
7
RELAY COIL
Y/BK
X5-9
BL
X5-1
24VAC
8
X5-2
O
LOUVER
WIFI
9
PROVING SWITCH
BLOCKED DRAIN SWITCH
DONGLE
P
X5-10
AIR PRESSURE SWITCH
X5-11
O/BK
10
-T
OUTLET SENSOR:
X5-4
R/BK
BLOCKED
OPERATING S1a
DRAIN SWITCH
-T
OUTLET SENSOR:
X5-12
GY
HIGH LIMIT S1b
-T
AIR PRESSURE
X5-6
P/BK
INLET SENSOR S2
SWITCH
-T
X5-5
W/BK
FLUE SENSOR S3a
-T
PR
FLUE SENSOR S3b
X5-13
GAS VALVE
X5-14
Y
X2-2
BK
GAS VALVE
BLOWER
@24VAC
X9-1
X2-1
Y
X9-2
X9-3
X1-7
W/R
FLAME SENSOR
X9-4
SPARK
TR2
ROD
CAUTION
HIGH VOLTAGE SPARK LEAD
SPARK
ROD
CAUTION
HIGH VOLTAGE SPARK LEAD
INTEGRATED
CONTROL
X-7
PUMP RELAYS
X1-3
OR
CN2-4
CN1-5
K1
3
CN5-4
X4-4
X5-2
X5-10
X5-11
X2-2
GAS VALVE
RELAY
X2-1
1
X5-7
2
X5-16
L
OUT
4
X5-8
5
X5-15
TR2
SYSTEM
X1-7
PUMP
FLAME ROD
BOILER
PUMP
DHW
PUMP
L
L
IN
OUT
JUNCTION
BOX
DHW
PUMP
OR
OR
BOILER
BR
PUMP
INTEGRATED
CONTROL
BR
PR
CN5-15
X4-8
SYSTEM
PR
PUMP
CN5-11 X4-12
L
120VAC
GND
SUPPLY
N
CN5-7
X4-1
X4-9
CN5-14
TRANSFORMER
CN5-6
X4-2
3A
X4-10
CN5-13
CN5-12
X4-11
CN5-16
X5-3
CN5-3
X4-5
Y
DAMPER RELAY
CN9
FLUE DAMPER
BL
2
1
M
3
CN5-4
X4-4
X5-2
X5-10
X5-11
X2-2
GAS VALVE
RELAY
X2-1
1
X5-7
2
X5-16
G
4
X5-8
5
X5-15
TR2
X1-7
FLAME ROD
100329773 REV C
L
L
IN
OUT
JUNCTION
BOX
DHW
PUMP
OR