Summary of Contents for Baudcom EDFA-1550

  • Page 1 SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Operating Manual 64 Port High power amplifier Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn...
  • Page 2: Table Of Contents

    SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Catalog Using Safety Precautions................................1 Application ....................................2 Feature ....................................2 Description: ................................... 2 Block Diagram ..................................2 Optical characteristics ................................4 Environmental characteristics .............................. 4 Electrical Characteristics ..............................4 Starting up ....................................5 Equipment Powered Instructions ............................5 LED/ Key Description ................................
  • Page 3: Using Safety Precautions

    SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Using Safety Precautions Before installing and using this product, please read the following carefully. The Company does not assume any responsibility for any loss due to security breaches caused. Lasers and erbium-doped fiber amplifier output power laser radiation is not visible, can not look directly at the device connector end when it works to avoid burning eyes and skin.
  • Page 4: Application

    SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Application ◆Analog CATV Transmission ◆FTTH Optical Access ◆Optical Distribution ◆Free Space Optical ◆R&D and Training Feature ◆High Power:Up to 2W total,1 Unit for 2000~4000 optical node ◆Low Noise Figure:Below 5.5dB ( +5dBm input) ◆Er Yb co-doped DCF Amplify Technology:Patent Pump Dump Technology ◆Low CSO: <-70dBc...
  • Page 5 SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn...
  • Page 6: Optical Characteristics

    SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Optical characteristics Parameter Symbol UNITS λc 1540 1550 1565 Operating Wavelength ------ Saturated Output Power Note1 ------ Input Power ------ ------ Gain ------ ------ Noise Figure Note2 ΔPo ----- ±0.05 ±0.2 Output Power Stability -------...
  • Page 7: Starting Up

    SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Starting up Before starting up, Please check the input voltage to the rated input voltage, grounding is good. The product adopts independent 220 VAC power supply. Equipment Powered Instructions Special Note: 1. The power module must be properly inserted in the device, so it can be supplied power.
  • Page 8: Indicator

    SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD (7)Press the down button to display the temperature of pump 2: **.* ℃ COOLER (8) Press the down button to display the operating current of pump 3: Current *.* A (9)Press the down button to display the temperature of pump tube 3: COOLER **.*℃...
  • Page 9: Interface

    SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD   AGC : When the AGC function is turned on the light turns green. Interface Front-Panel、Back-Panel Connectors Description Input Optical input port 1~16 Optical output ports RJ45 Ethernet control port Power1/2 Power input 110/220V AC...
  • Page 10: Web

    SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Web Managment Login 1. Open Internet Explorer; 2. Input IP address into address box; 3. After the [Login] page have shown up, input UserName and password; 4. Press Login botton; Note: *1: Default IP address is 192.168.1.1 which can be modified at [Network Config] web page;...
  • Page 11: Device Infomation

    SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Device Infomation After at successful login, the [Device Information] page will show up. There’re three sections. 1. Device PowerMode: The name of electrical power source is using; LaserCount: Total number of laser pump is used;...
  • Page 12: User Management

    SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD This page modifies the network parameters. User Management This page modifies the login account. You can change the user name and password here. Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn...
  • Page 13 SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn...
  • Page 14: Snmp Config

    SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD SNMP Config This page modifies the SNMP Community. You can changed the community of read or write here.(Only read community is using.) Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn...
  • Page 15: Snmp

    SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD SNMP Management SNMP Version 1 protocol is supported. The device related mib are defined as below. function 1.3.6.1.4.1.17409.1.11.2.0 Optical Input Power value*0.1dBm 1.3.6.1.4.1.17409.1.11.3.0 Optical Output Power value*0.1dBm 1.3.6.1.4.1.17409.1.11.4.1.2.1 Bias Current.1 value*1mA 1.3.6.1.4.1.17409.1.11.4.1.2.2 Bias Current.2 value*1mA(Reserved) 1.3.6.1.4.1.17409.1.11.4.1.2.3...
  • Page 16 SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD Category Application Input Power — Output — ports Power Power Interfa Network Power supply1 supply2 Management - - EDFA-1500 1U/ 2U/3U Rack 1: CATV 1-5~+10dBm; 13:13dBm 1:1 port 1:110VAC 1:110VAC 0:None 1:SC/UPC 2:+5~+15dBm; 2:220VAC 2:220VAC 1:SNMP...