Yoke PT-2000S Operation Manual

Yoke PT-2000S Operation Manual

Portable turbidity meter

Advertisement

Portable Turbidity Meter
Operation Manual
Please read and adhere to all recommendations in this manual to ensure the best experience and to maintain your
Turbidity Meter in good working order. The manual is for the following models: PT-2000S, PT-2000H

Features

● 4.3 inch colored TFT screen with friendly UI.
● Contain 200 curves and customize high precision test curve according to measurement ranges. Users can
set up different piecewise curve and coefficient subject to different concentrations which will literally
improve measurement precision.
● ARM9 main control chip makes operations easy, response quick and big storage up to 500M.
● Adopt special and high precision light filter system to ensure the instruments' stability and accuracy.
● Cold light source, narrowband interference, with long lifetime up to 100,000 hours.
● Advanced power management system can show the battery status in real time and be charged via USB
port on PC or vehicle.

Technical Parameters

Model
Description
Minimum readout (NTU)
Measuring range (NTU)
Basic error
Repeatability
Zero Drift
Power
Output
Dimensions/N.W.
Standard Accessaries
PT-2000S
Smart Turbidity
0.01
5-10, 10-100, 100-1000
±5%FS
±0.5%FS
Charging Voltage: DC 5V, Lithium Battery: 3.7V/5200mA
210×105×65mm/500g
Cuvette cup x 2 pcs, Charger, Suitcase, Manual
PT-2000H
High-precision Turbidity
0.001
±3%FS
≤0.5%
±0.5%FS
Micro USB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PT-2000S and is the answer not in the manual?

Questions and answers

Summary of Contents for Yoke PT-2000S

  • Page 1 Operation Manual Please read and adhere to all recommendations in this manual to ensure the best experience and to maintain your Turbidity Meter in good working order. The manual is for the following models: PT-2000S, PT-2000H Features ● 4.3 inch colored TFT screen with friendly UI.
  • Page 2 Operation Procedure The Meter has been calibrated before leaving the factory with built-in curve. The user can directly determine the turbidity value of the sample according to the following methods. 1. Press START to turn it on. 2. Pour the reference solution into a random colorimetric bottle, no more than two-thirds of the volume of the colorimetric bottle.
  • Page 3 standard sample according to own needs, reading the values of different concentration samples with the meter, and then calculating the curve. f. Single point calibration curve refers to the function that the user prepares a sample with known concentration to carry out single point calibration on the existing curve, so as to modify the parameters of the original curve.

This manual is also suitable for:

Pt-2000h

Table of Contents