7. TROUBLESHOOTING
Problem
Cause
All digits appear
Battery power low
simultaneously
and change rapidly
Display does not
Poor voltage when
work (only when
replacing battery
changing the
battery)
Reading error for
Dirt has damaged/
full length is ≤
covered sensor
0.1mm
Nothing appears
Poor battery
on the LCD
contact or battery
voltage is under
1.1V
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
ENVIRONMENT PROTECTION
.
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
Solution
Replace battery
Remove battery
and replace it after
30 seconds
Remove cover and
slider assembly.
Check battery
contact or replace
battery
01284 703534