Problem Areas
1.34 Water Resistance
1.34.1 Water Resistance test fails
Check:
Inspect that the Vacuum Cup is correctly mounted to
ventilation hole.
Run the Water Resistance Test again!
Check:
Inspect that the primary microphone is properly sealed with
tape.
Check:
Inspect that the secondary microphone is properly sealed
with tape.
Action:
Reseal the openings with tape.
Run the Water Resistance Test again!
Check:
Inspect the equipment:
Check the connections between the tube and houses.
Check the Vacuum Cup sealing area and the syringe.
Check for dirt, cracks, damages.
Check direction on the valve.
Action:
1. If any bad connection – remount the equipment.
2. If damaged – replace the equipment.
1265-6294 Rev 4
© Sony Mobile Communications AB – Company Internal
Troubleshooting Guide (mech)