Download Print this page

Hasco Loc Check A5900/ Series Manual page 8

Advertisement

Available languages

Available languages

also limited by the self-discharge of the battery (1-3% monthly, depending on the
temperature).
§ Voltage curve (Fig. 2) of the Li-Ion battery used at 21° C until complete discharge (no
longer safe to operate) after 3700 transmission cycles. The horizontal line indicates
the minimum voltage of 6.8 V required for reliable operation. Falling below this value
must be avoided in any case!
Fig. 2: Discharge characteristics of the Li-Ion battery used
b. Charging mode
The Loc Check asset tracker may only be charged with a suitable power supply unit
(8.4 V; 1.3 A) via the charging pins or with a suitable power plug (8.4 V; max. 2.6 A).
A green lamp on the power plug lights up from >90% of the battery's charging capacity
to indicate that the tracker is charged.
6. CE & UKCA
§ The tracker meets the requirements for the CE and UKCA mark. The declarations of
conformity can be viewed on our website at https://loc-check.com/compliance.
www.loc-check.com
8
www.hasco.com

Advertisement

loading

This manual is also suitable for:

A5901/n1A5900/l1xb1xh1