UT501B Insulation Resistance Tester is designed with brand-new
design and combination of massive integrated and digital circuits; it
can measure insulation resistance, low resistance, AC voltage, etc,
and enjoys high degree of accuracy, stable performance, easy
operation and reliability. It is used for insulation resistance
measurement for insulation materials and various kinds of electric
equipments such as transformer, electric machines, cables,
switches, electrical appliances, a ideal tool for electric equipment
maintenance, testing and inspection.
Safety Information
The tester is designed and manufactured in compliance with
IEC61010 standard. The manual covers safety information related
to the safe operations and conditions of the instrument. please read
carefully before using the instrument.
Warning
Use always as specified in the manual, and keep it for future use.
conditions and actions that may cause serious or
fatal damage.
Alerts users to avoid electric shock.
conditions and actions that may cause damage to
the instrument or affect accurate measurement.
voltage over 750VAC.
test leads lead when measuring.
When test leads are shorted and connected to the instrument, do
not press TEST key.
during test.
Do not touch the tested line during insulation measurement.
Eg: the instrument damaged or had exposed metal.
is
discharged.
between test leads and test ports
resistance measurement.
leads
leads
low battery indicator shows
properly.
Electrical Symbols
Risk of electric shock
Accuracy: ±( a% of reading + b digits ), calibration per year.
Insulation Resistance Measurement
Rated current
Shorted Current
Polarization Index/Dielectric Absorption Ratio Measurement
PI Measurement
PI Value
DAR Measurement
DAR Measurement
DAR Value
Low Resistance Measurement
Voltage Measurement
Low battery indication:
Overload indication: ">5.5GΩ" shows under insulation resistance
measurement.
display the unit and function simultaneously
Automatic voltage release
Backlight for work in dark sites
Red light for warning
Altitude:
under normal condition.)
test leads,
operating manual, carrying case.
Safety compliances: Overvoltage CATIII 600V, Pollution
Degree 2 as per IEC61010
5. Tester's Structure(Front View)
measurement
for insulation resistance measurement
Switch button for PI/DAR
Test button
Rotary knob
LCD Display
Buttons and Rotary Knob
1. PI/DAR button: measures polarization index/dielectric absorption
ratio.
2. ZERO/LIGHT button: turns on/off the backlight or resets the
display to zero for low resistance measurement.
3. TEST button: turns on/off insulation and low resistance
measurement.
4. Rotary knob set to ACV: to measure AC voltage.

Advertisement

loading
Need help?

Need help?

Do you have a question about the UT501B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for UNI-T UT501B

  • Page 1 ● Safety compliances: Overvoltage CATIII 600V, Pollution Degree 2 as per IEC61010 UT501B Insulation Resistance Tester is designed with brand-new design and combination of massive integrated and digital circuits; it 5. Tester's Structure(Front View) can measure insulation resistance, low resistance, AC voltage, etc,...
  • Page 2 P/N:110401104397X 5. Rotary knob set to CONTINUITY: to measure low resistance. Dielectric absorption ratio measurement 6. Rotary knob set to 250V/500V/1000V: (See Figure 3) Under insulation measurement mode, press PI/DAR button two to select test voltage for insulation resistance measurement. times to select DAR parameter, the screen displays Time 1(30s)/ Time2(1min), then press TEST to start DAR measurement, then press TEST three times to select another DAR, the screen shows...