Dansons group inc. pellet stove can/csa b365 operations guide (13 pages)
Summary of Contents for Dansons Group CC2
Page 2
Thank you for selecting a VULCAN “V” SERIES wood pellet appliance. Sincerely, Canadian Comfort Industries & Dansons Group Inc. Up to date additions, product information, product registration and warranty extension registration can be found on Copyright 2005, Canadian Comfort Industries. All rights reserved.
CAUTION: NEVER put fingers in or near pellet feed auger. The pellet fuel is fed to the burn pot by a screw auger that is driven by a high torque motor. This auger can start and stop anytime automatically without warning while stove is operating. Copyright 2005 Canadian Comfort Industries RECAUTIONS www.stovesunlimited.com Vulcan V SERIES Owner’s Manual Dansons Group Inc.
A Mobile Home Heater. The Safety Listing Label is located on the rear inspection panel for model CC1, CC2, and CC3. Please read the label carefully. It contains important information about installation and operation of your pellet appliance. Note that your STOVE’S serial number is located on the safety label.
Page 6
Vulcan V SERIES Copyright 2005 Owner’s Manual Canadian Comfort Industries www.stovesunlimited.com Dansons Group Inc.
For further information contact your local Specialty Retailer, Certified HVAC Service Depot, or Dansons Group Inc. Customer Service Department at 1-866-456-9269. Copyright 2005 Canadian Comfort Industries AFETY EATURES Low Limit L120 Vulcan V SERIES www.stovesunlimited.com Fan Limit F140 Owner’s Manual Dansons Group Inc.
12 ½” Air Inlet = 115 Volts 60 HZ 2.0 Amps = 175 (approximately) = 475 (approximately) www.stovesunlimited.com 26” 24” 8 1/4” Exhaust 8 3/4” 14 1/4” “V” Series V-150 Vulcan V SERIES Owner’s Manual Dansons Group Inc. 31 1/2”...
Page 9
(figure 6). Then light the stove according to the directions outlined in "LIGHTING YOUR STOVE", Copyright 2005 Canadian Comfort Industries NSTALLATION for Extended Warranty. www.stovesunlimited.com HECK Vulcan V SERIES Owner’s Manual Dansons Group Inc.
3. An ALCOVE: When placed on a non-combustible floor pad in compliance with clearance requirements for an installation in an alcove (a recessed space or nook in a wall). Figure 1 Copyright 2005 Canadian Comfort Industries PTIONS HOME & SHOP HEATER. Figure 2 www.stovesunlimited.com Vulcan V SERIES Owner’s Manual Dansons Group Inc.
Page 11
If venting outside of shaded area. “PL” Vent, if venting in shaded area. must 0’ www.stovesunlimited.com GENERAL 25’ 4” Diameter “PL” Vent 3” 4” Diameter 15’ 10’ 5’ 10’ Vulcan V SERIES Owner’s Manual Dansons Group Inc. 33’ 30’ 20’ 5’ 0’...
Must be a minimum of 36” above the roof and 24” above the highest point of the roof within 10’. Copyright 2005 Canadian Comfort Industries . . . Continued (Figures 7 & 8) www.stovesunlimited.com Figure 8 3’ 2’ 10’ Figure 9 Vulcan V SERIES Owner’s Manual Dansons Group Inc.
1 – 2” Aluminum Flex Duct – compressed 15” length, extends to 30” – 36” 2 – 2” Worm Gear Clamps NOTE: Available from your local Authorized Dealer or Dansons Group Inc. 1-877-303-3134 Figure 11 Copyright 2005 Canadian Comfort Industries...
3” From PL Vent to Combustibles 6” Non Combustible Surface In Front Of Heater 36” to drapes, doors, anything that can swing 3” 1” 1” 10” 10” www.stovesunlimited.com NTERIOR ERTICAL 10” 6” Figure 13 Vulcan V SERIES Owner’s Manual Dansons Group Inc.
Page 15
10” 6” 6” Figure 16 Copyright 2005 Canadian Comfort Industries . . . continued 12” 1” 1” 10” 10” www.stovesunlimited.com 45 C ORNER NTERIOR ERTICAL 10” 6” Figure 15 16” Figure 17 Vulcan V SERIES Owner’s Manual Dansons Group Inc.
This is due to backpressure in the exhaust, caused by the airflow around the house. Copyright 2005 Canadian Comfort Industries NSTALLATION . . . continued www.stovesunlimited.com (Figure 18) HROUGH 12” 1” 1” 10” 10” 6” 6” Vulcan V SERIES Owner’s Manual Dansons Group Inc.
Figure 24. Figure 19 Figure 22 Copyright 2005 Canadian Comfort Industries . . . continued (Figures 19 - 24) Figure 20 Figure 23 Vulcan V SERIES www.stovesunlimited.com Figure 21 Figure 24 Owner’s Manual Dansons Group Inc.
Page 18
Stove Exhaust Pipe Adapter Clean Out Tee Tee Support Bracket Pipe Firestop Spacer / Ceiling Support Roof Flashing / Storm Collar Rain Cap Floor Pad (ground wire) www.stovesunlimited.com Floor Frame (bolts) Figure 26 Vulcan V SERIES Owner’s Manual Dansons Group Inc.
Page 19
2. If stove fails to ignite a second time, disconnect and contact your dealer. 3. Adjust the FUEL RATE and the FAN SPEED to your desired settings you require upon completion of startup sequence. www.stovesunlimited.com Vulcan V SERIES Owner’s Manual Dansons Group Inc.
Page 20
The FEED RATE works in a synchronized manner setting both the fuel rate and combustion air at the same time. When fuel is increased by setting the FEED RATE ANUAL OR HERMOSTAT HERMOSTAT www.stovesunlimited.com ONTROLS Vulcan V SERIES Owner’s Manual Dansons Group Inc.
NO LED’s will remain ON. Copyright 2005 Canadian Comfort Industries CONTINUED – Factory Settings www.stovesunlimited.com Decrease FINE TUNE ADJUSTMENTS FAN SPEED from high to low is Vulcan V SERIES Owner’s Manual Dansons Group Inc. Increase AUGER CYCLE SPEED...
Page 22
LED’s #3 and #4 flash together this indicates the thermostat will run in the HIGH / LOW cycle. When the #1 and #2 LED’s flash together this indicates the ON / OFF cycle has been chosen. (Flashing 3 & 4) (Flashing 1 & 2) www.stovesunlimited.com (option) Vulcan V SERIES Owner’s Manual Dansons Group Inc.
Page 23
In a few instances the speed and INCREASE fuel rate turn trimmer stays “OFF”. (Note: The light stays “off” when ever Vulcan V SERIES Owner’s Manual Dansons Group Inc. Air Inlet Slide Rod Rubber GrometT Right Hand Side Panel Increase...
Contributing factors: venting system providing excessive draft. Refer to the "Trouble Shooting Guide" section of this manual, and if necessary, contact your local Specialty Retailer, Certified HVAC Service Depot, or Dansons Group Inc. Customer Service Department at 1-866-456-9269. Copyright 2005...
12 – 15 hours 3.50 to 4.50 lbs. Per hour 10 – 14 hours 4.00 to 5.50 lbs. Per hour VULCAN “V” Series Dealer. There may be a service charge for these www.stovesunlimited.com Vulcan V SERIES Owner’s Manual Dansons Group Inc.
NOTE: Since Dansons Group Inc. or Canadian Comfort Industries has no control over the quality of pellets that you use, we assume no liability caused by the quality of wood pellets used.
Tube Scraper Burn Grate [COLD STOVE ONLY as hot glass may cause serious burns] To enjoy a www.stovesunlimited.com LEANING Heat Tubes Window Burn Pot Ash Pit Vulcan V SERIES Owner’s Manual Dansons Group Inc.
Removal of burn grate top: (1)Lift upward while sliding lip out from under lip of slide (2)Then pull out toward outside of burn box (3) Installation is reverse of this. www.stovesunlimited.com Vulcan V SERIES Owner’s Manual Dansons Group Inc.
RIODIC We recommend using a high quality glass cleaner. Should a In the event you need replacement only Neo-Ceram of the correct size and www.stovesunlimited.com Use a damp cloth to clean your Vulcan V SERIES Owner’s Manual Dansons Group Inc.
Page 30
A yearly servicing and cleaning by your Authorized VULCAN F22 Dealer is Hopper Lid Heat Tubes Tube Scraper Window Burn Grate Burn Pot Ash Pit www.stovesunlimited.com Hopper Auger Auger Motor Fan Motors Exhaust Air Intake Base Vulcan V SERIES Owner’s Manual Dansons Group Inc.
VULCAN “V” Series Dealer for service. VULCAN “V” Series Dealer for service. VULCAN “V” Series Dealer for service. VULCAN “V” Series Dealer for service. VULCAN “V” Series Dealer for service. www.stovesunlimited.com VULCAN “V” Series Vulcan V SERIES Owner’s Manual Dansons Group Inc.
Copyright 2005 Canadian Comfort Industries IMITED ARRANTY or online at www.dansons.com/support VULCAN “V” Series SUPPLIERS www.stovesunlimited.com home and shop heaters as the PURCHASER, ACCEPTS Vulcan V SERIES Owner’s Manual Dansons Group Inc.
Wall Thermostat – USA version Copyright 2005 Canadian Comfort Industries “A” PPENDIX OPTIONAL ACCESSORIES DEALER FOR MORE INFORMATION OR TO ORDER. www.stovesunlimited.com PART NUMBER ACWTKTC ACWTKTF AHDRBAS ACDRBAS ACDRGAS ACFAKT3 ACFAKT10 AHIGNAS ACLOGCL1 ACWTC ACWTF Vulcan V SERIES Owner’s Manual Dansons Group Inc.
- 1of each fan, motor, AGDSAKT ACDDG ACCVLTM ACDSHB ACFLCKN ACDPSHB ACLSW120 ACHSW250 ACISW140 ACPRSW ACSTSWPB AHFPSW ACTMR30M ACTMR03S ACSBMNWH ACSBCPWH ACATMNWH ACPWCDAS ACWTKTAC ACWTKTAF ACWTKTC (white Deg C) ACWTKTF (white Deg F) Vulcan V SERIES Owner’s Manual Dansons Group Inc.
Page 35
REQUIRED FOR THE STOVE TO OPERATE IN MANUAL MODE Copyright 2005 Canadian Comfort Industries “C” PPENDIX Wall Thermostat INSTALLATION figure 32 figure 33 www.stovesunlimited.com (option) VULCAN “V” Series dealer. figure 34 (SEE FIGURE 32) Vulcan V SERIES Owner’s Manual Dansons Group Inc.
9. Raise and lower the access panel as needed. 10. When finished cleaning out as many pellets as possible, re-install the 5 screws, remove the drop chute, replace the 2 screws and then install the side panel. www.stovesunlimited.com Vulcan V SERIES Owner’s Manual Dansons Group Inc.
Copyright 2005 Canadian Comfort Industries Toll F i c a l Su pport URCHASER DDRESS TATE HONE NSTALL ERIAL UMBER ESCRIPTION OF WORK DONE See www.dansons.com/support www.stovesunlimited.com ’ TATE /PC: HONE NSTALLED URNED Vulcan V SERIES Owner’s Manual Dansons Group Inc.