LATICRETE STRATA HEAT Operating Manual

LATICRETE STRATA HEAT Operating Manual

Hide thumbs Also See for STRATA HEAT:

Advertisement

Wi-Fi Thermostat
Operating Manual
Wi-Fi

Advertisement

Table of Contents
loading

Summary of Contents for LATICRETE STRATA HEAT

  • Page 1 Wi-Fi Thermostat Operating Manual Wi-Fi...
  • Page 2: Table Of Contents

    Pack Contents Contents Safety Information ............................3 Step 1 – Installation ............................3 Step 2 – Wiring Connections .........................4 Table 1.0 – Thermostat use cases ....................5 Wiring Diagrams – over 15 Amps ....................6 Step 3 – Thermostat Mounting ........................7 Step 4 – Initial Setup..........................7-8 Welcome to the STRATA_HEAT Wi-Fi Thermostat .....................9 ™...
  • Page 3: Safety Information

    Safety Information The STRATA_HEAT Wi-Fi Thermostat must be installed by a qualified electrician. It requires a permanent 110V ™ – 240V AC, 60Hz supply. The STRATA_HEAT Wi-Fi Thermostat contains a Class A GFCI with 5mA trip level and wiring must conform to local electrical code. Isolate the STRATA_HEAT Wi-Fi Thermostat from the mains supply throughout the installation process.
  • Page 4: Step 2 - Wiring Connections

    Step 2 – Wiring Connections WARNING! The STRATA_HEAT WiFi Thermostat must be installed by a qualified electrician in accordance with ™ National Electrical Code. Wiring Connections LOAD L1 Heater Load Max.15A (1800W/120V, 3600W/240V) & L2 LINE Supply Live (120 V) LINE Supply Neutral (120 V) / Supply Live (240 V) Probe 1 –...
  • Page 5 Table 1.0 – Thermostat use cases Use Case Control Limit Sensor Thermostat IN room Internal Air temperature schedule None Air Sensor No floor limit Thermostat IN/OUT of room Floor temperature P1 & PC None schedule Floor limit Floor Sensor Thermostat IN room P1 &...
  • Page 6: Wiring Diagrams - Over 15 Amps

    Wiring Diagrams Heating Load connected to STRATA_HEAT Wi-Fi Thermostat and Relay 25 – Max. 40 Amps ™ Snubber (contact suppressor) 240V 240V SUPPLY WITHOUT GFCI COIL SUPPLY PROTECTION L1-LOAD-L2 Hot (240V) L1-LINE HEATING Hot (240V) (MAX 3600W/ L2-LINE 15 Amps) L1-LINE-L2 240V GFCI POWER...
  • Page 7: Step 3 - Thermostat Mounting

    Step 3 – Thermostat Mounting 1,500W Insert fixing screws through mounting holes of the power Re-attach the display to the power base. You can base and tighten. now restore power to the circuit and power up the STRATA_HEAT Wi-Fi Thermostat. ™...
  • Page 8: Step 4 - Initial Setup

    Step 4 – Initial Setup ‘MySTRATA_HEAT’ by LATICRETE Download the MySTRATA_HEAT App. Open the MySTRATA_HEAT App and scan the QR Code on the STRATA_HEAT Wi-Fi Thermostat screen protector or on reverse of the display. Follow the instructions in the App...
  • Page 9: Welcome To The Strata_Heat ™ Wi-Fi Thermostat

    Welcome to the STRATA_HEAT Wi-Fi Thermostat ™ Next/Accept Back/Cancel Up/Down Change value/setting How to quickly change the temperature Press to change your target temperature. If in program mode this will set a temporary override until your next heating period. See “How to set a temporary override”. If in manual mode this will set a fixed target temperature.
  • Page 10: Heating

    Heating How to set a program Setting a “Program” allows you to set comfort temperatures at set times throughout the day. Days can programmed individually, all days the same or weekdays as a block and weekends as a block, the choice is yours. Edit Program To select the days you wish to program press...
  • Page 11: How To Set Into Manual Mode

    Heating How to set into Manual Mode Setting into “Manual” mode allows you to set a fixed target temperature for the thermostat to achieve. The thermostat will continue to maintain this temperature until another operating mode or temperature is selected. 73º...
  • Page 12: Energy Monitor

    Geo Location Settings How Geo Location works Geo is a unique technology developed by LATICRETE and built into the MySTRATA_HEAT App that uses an advanced algorithm to understand the most efficient heat settings for your home. Working automatically; it learns your routines and location through...
  • Page 13: Settings

    Settings Date and time Set the current date and time. 6-5-2021 Press to begin, press to change date/time. 13:00 Press to confirm. Thermostat application Swaps probe usage, 1 being the Control Sensor Probe and 2 being the Limit Sensor Probe. Press to swap probe usage.
  • Page 14 Settings Change homescreen override color Select the override color Open window function The windows open detection feature is designed to switch off heating to save energy when the thermostat detects that a window or door has been opened. Display lock Switch display lock on 0 0 0 Set display lock code...
  • Page 15: Notifications And Error Codes

    Notifications & Error codes Date and time needs to be set Heating switched OFF Open window function triggered Display locked Temporary override enabled Sensor P2 (6 & 7) error - - - Holiday mode enabled. Sensor P1 (5 & 6) not connected / (Configured in MySTRATA_HEAT App) damaged or Internal air sensor fault Frost protect enabled.
  • Page 16 If correctly wired please conduct a resistance test and insulation resistance test on the heater to see if damage has occurred. Relay icon Relay error The STRATA_HEAT W-iFi Thermostat has detected that one of the relays has FAILED. Please contact LATICRETE GFCI...
  • Page 17: Wi-Fi Troubleshooting

    Wi-Fi Network? Set up a mobile hotspot using a smartphone. On If the STRATA_HEAT Wi-Fi Thermostat Contact LATICRETE with your a separate device login to the MySTRATA_HEAT connected to a mobile hotspot then distance router make and model app.
  • Page 18: Technical Specifications

    Technical Specifications Model RSW-XX-YY-ZZ Operating Voltage 110V - 240V AC +/–15% 50Hz/60Hz Protection Class 15A resistive Max. Load (120 V – 1800W, 240 V – 3600W) GFCI Class A GFCI with 5mA trip level Rated impulse voltage 4000V Automatic action 100,000 Disconnection means Pollution degree...
  • Page 19: Warranty

    Contact LATICRETE. LATICRETE will determine whether the product should be returned or replaced. The 1 year warranty only applies if the product is registered with LATICRETE within 30 days after purchase. Registration can be completed online at www.laticrete.com...
  • Page 20 LATICRETE International, Inc. One LATICRETE Park North, Bethany, CT 06524-3423 USA ■ + 1.203.393.0010 1.800.243.4788 www.laticrete.com ■ ■ DS-10048-0122 ©2022 LATICRETE International, Inc. All trademarks shown are the intellectual properties of their respective owners.