Safety Information The STRATA_HEAT Smart LCD Thermostat must be installed by a qualified electrician. It requires a permanent ™ 110V – 240V AC, 60Hz supply. The STRATA_HEAT Smart LCD Thermostat contains a Class A GFCI with 5mA trip level and wiring must conform to local electrical code. Isolate the STRATA_HEAT Smart LCD Thermostat from the mains supply throughout the installation process.
Step 2 – Wiring Connections WARNING! The STRATA_HEAT Smart LCD Thermostat must be installed by a qualified electrician in accordance with ™ National Electrical Code. Wiring Connections LOAD L1 Heater Load Max.15A (1800W/120V, 3600W/240V) & L2 LINE Supply Live (120 V) LINE Supply Neutral (120 V) / Supply Live (240 V) Probe 1 –...
Page 5
Table 1.0 – Thermostat use cases Use Case Control Limit Sensor Thermostat IN room Internal Air temperature schedule None Air Sensor No floor limit Thermostat IN/OUT of room Floor temperature P1 & PC None schedule Floor limit Floor Sensor Thermostat IN room P1 &...
™ screen instructions to set up the system. Once set up, a QR Code will appear. Step 4 – Initial Setup ‘MySTRATA_HEAT’ by LATICRETE Network Setup Open the MySTRATA_HEAT App on your phone and scan this code to proceed Dismiss Download the MySTRATA_HEAT App.
Welcome to the STRATA_HEAT Smart LCD Thermostat ™ Heating Indicator Displays when heating is active Error Messages See Troubleshooting Page Current Floor/Air temperature Floor will be displayed if floor sensor is installed Thu 11 Mar 17:00 and switched on Temporary Override Use the slider or press the +/–...
Heating How to set a program Setting a “Program” allows you to set comfort temperatures at set times throughout the day. Days can programmed individually, all days the same or weekdays as a block and weekends as a block. The choice is yours. Thu 11 Mar 17:00 Menu...
Heating How to set into Manual Mode Setting into “Manual” mode allows you to set a fixed target temperature for the thermostat to achieve. The thermostat will continue to maintain this temperature until another operating mode or temperature is selected. Thu 11 Mar 17:00 Menu...
Heating How to set into Vacation Mode “Vacation Mode” allows you to override regular scheduling with a lower fixed temperature over a set time to save energy and avoid thermostat re–programming. Thu 11 Mar 17:00 Menu Mode Mode Program Manual Program 70.0 Energy Monitor...
Accept Geo Location Settings How Geo works Geo is a unique technology developed by LATICRETE and built into the MySTRATA_HEAT App that uses an advanced algorithm to understand the most efficient heat settings for your home. Working automatically; it learns your routines and location through...
Light Dark Random Choose the background image of the STRATA_HEAT Smart LCD Thermostat. ™ Random is an image selected from the LATICRETE collection. Temperature Standby style Time Minimalist Choose what will be displayed when the STRATA_HEAT Smart LCD Thermostat goes into standby.
Settings Display, cont’d Night period Set the Start and End period This is the time when you usually go to bed at night and wake up in the morning. The brightness of “Night” mode will begin and end using this time. On/Off Screen lock Locks the STRATA_HEAT...
Advanced Settings Advanced settings, cont’d Temperature limits Set Min./Max. settable temperature limits Set Overheat air limit if floor sensor has been installed Overheat limit Control Period Set between 10 – 60 mins. Control period checks the difference in the current measured temperature and the set temperature in a proportional integral algorithm to maintain a steady temperature.
Thermostat connect to your Wi-Fi Network? Set up a mobile hotspot using a smartphone. On If the STRATA_HEAT Smart LCD Thermostat Contact LATICRETE with your a separate device login to the MySTRATA_HEAT connected to a mobile hotspot then distance router make and model app.
Technical Specifications Model 0804-0404-TW/TB Voltage 110V – 240V AC +/–15% 50Hz/60Hz Protection 15A resistive Max. Load (120 V/1800W, 240 V/3600W) GFCI Class A GFCI with 5mA trip level Rated impulse voltage 4000V Automatic action 100,000 Disconnection means Pollution degree Max. Ambient Temperature 40°C / 104°F (T40) Relative Humidity IP Rating...
Contact LATICRETE. LATICRETE will determine whether the product should be returned or replaced. The 1 year warranty only applies if the product is registered with LATICRETE within 30 days after purchase. Registration can be completed online at www.laticrete.com...