Auto Tension Release - Janome 1600P-QC Service Manual

Hide thumbs Also See for 1600P-QC:
Table of Contents

Advertisement

0.5 - 1.0mm
e
w

6. Auto Tension Release

z
c
• If the gap is too wide, tun the adjusting nut counterclock
wise.
• If the gap is too narrow, tun the adjusting nut clockwise.
v
q
28
Turn the handwheel toward you to raise the needle
bar until the needle point is just above the needle
plate.
Set the tension dial at 4 and push the solenoid disk
fully to the right. The tension disks should open 0.5 –
1 mm.
Loosen the lock nut
w
adjust the gap between the tension disks.
w
Tighten the lock nut
.
and turn the adjusting nut
q
e
to