24140 Speaker wall mount
- Stable model, suitable for loudspeakers up to a max. of 35 kg
- Equally suited for home, object and public areas
- Suitable for flange bushings - internal diameter 36 mm
- The speaker distance to the wall can be individually adjusted in 4 positions
- The wall mount is largely covered by the loudspeakers
Thank you for choosing this product. The instructions provide
directions to all of the important setup and handling steps. We
recommend you keep these instructions for future reference.
1. SAFETY NOTES
- Check the mount for damage prior to and after use.
-
Do not continue to use damaged mounts.
- Maximum centered load: 35 kg
- not suitable for outdoors or moist rooms.
- please refer to local mounting instructions (may possibly
-
deviate from the examples provided in Section 5 A, B, C)
- use 4 screws for the wall mount
- only use trained technicians to assemble the system
- only mount on suitable walls with the corresponding
-
assembly material (not included in the delivery)
- walls, that are too weak or have electrical and water conduits
-
or the like are unsuitable. In case of doubt consult a qualified
-
technician.
- regularly check that the screws are tight and the conditions of
-
the parts and components are in working order.
- Careful and attentive handling is required when adjusting the
-
loudspeakers, because the adjustment options can result in
-
the pinching or wedging of your hand.
- when using the holder at "events and production sites for
-
scenic presentations" BGV C1 applies accordingly.
2. PARTS - OVERVIEW
Conduct a visual inspection to ensure that all the parts are
included and are in working order.
UNPACKAGED PARTS: A Support tube with pre-mounted bolts, B Corner plate 2x, C Wall tube, D Fastening clip 2x
PARTS BAG:
e 1x Protective cap M10, f 8x Protective caps M8, g 4x Safety nuts M8-SW13, h 4x Hexagon screws M8 x 60 mm-SW13,
i 4x U-disks ø8,4/24 mm, j 4x Adjustment caps
3. ASSEMBLY
1.1 Pace each cover j on the plates D until it clicks in place.
1.2 Place plates through the slit in wall tube C.
1.2
NOTE: Hold the pieces in such a way that the back of the tube and the cover
1.2
form a line AND the round part of the cover faces forward.
OK!
The back wall
of the wall tube
and the cover
are flush
The radius of
the cover
in the front
1.3 Now slip on the remaining two covers j into place until they click.
2 Hold both corner plates B to the drill hole on the wall tube C and screw it
2
on using two hexagon screws M8 x 60 h and safety nuts M8 g.
3 Connect support tube A to the wall tube C.
3.1 To accomplish this, place the plates of the support tube in the slits of
3.1
the wall tubes.
3.2 Place two hexagon screws M8x60 h through the corresponding drill holes
3.2
in the corner plates B and the support arm and tighten the safety nuts M8 g.
3.3 To accomplish this, use the two open-end or ring spanners SW13
3.3
(not included with the delivery).
4 NOTE: The mounting bolt is placed in one of FOUR possible drill holes
4
and is not tighten in the pre-mounted state.
4.1 Please select the desired position of the bolt and then screw it tight to support
4.1
tube (A) To accomplish this, hold the screw head at the top with an Allen
4.1
wrench / hexagon key SW8 and tighten the safety nut M10 between
4.1
the disk using an open-end or ring spanner SW17.
5 After the installation of the screws, place the protective caps (e-1x, f-8x)
5
on the screws.
6 The four U-discs i are used as spacers for the wall mount.
Incorrect!
2. Back walls
2.
are not flush
1. The radiuses
are in the back
NOTE:
The Safety Nut M10 is only tighten a bit at delivery.
Select the desired position for the fitting bolt (a selection of 4 options are
available) and tighten the nut as described in 4.1.
3. Combination
3.
of 1. and 2.

Advertisement

loading

Summary of Contents for K&M 24140

  • Page 1 24140 Speaker wall mount - Stable model, suitable for loudspeakers up to a max. of 35 kg - Equally suited for home, object and public areas - Suitable for flange bushings - internal diameter 36 mm - The speaker distance to the wall can be individually adjusted in 4 positions - The wall mount is largely covered by the loudspeakers Thank you for choosing this product.
  • Page 2 38 mm internal diameter (US Variant) R: Check the loudspeaker, in particular, the internal diameter of the F :R: connector. This should be between 35 and 36 mm. KÖNIG & MEYER GmbH & Co. KG Kiesweg 2, 97877 Wertheim, www.k-m.de 24140-000-55 Rev.07 03-80-339.00 3/16...
  • Page 3 GENERAL SAFETY AND ASSEMBLY INSTRUCTIONS MOUNTING ACCESSORIES for overhead installations (e.g. wall, ceiling and truss mounts) 1. General safety instructions These mounting accessories may only be mounted and used: - by qualified personnel familiar with the relevant regulations, - in accordance with local and state regulations and the regulations for occupational insurance schemes - as described in the assembly instructions (=installation and operating instructions), - after a fault-free functional and visual inspection (completeness, operational safety;...