CFM CX3000 User Manual

Complete air purification system whole house unit

Advertisement

Quick Links

CX3000
Complete Air Purification System
Whole House Unit
[Duct Mounted]
User's Guide
Read and save these
Instructions
Continental Fan Manufacturing Inc.
Buffalo, NY, U.S.A.

Advertisement

Table of Contents
loading

Summary of Contents for CFM CX3000

  • Page 1 CX3000 Complete Air Purification System Whole House Unit [Duct Mounted] User’s Guide Read and save these Instructions Continental Fan Manufacturing Inc. Buffalo, NY, U.S.A.
  • Page 2: Table Of Contents

    PARTS LIST ........14 CX3000 EXPLODED VIEW ....... 15...
  • Page 3: Important Safety Instructions

    Warning - Always unplug the power cord from the CX3000 air purifier when changing the filter or ultraviolet lamps. Never look into a burning ultravi- olet lamp without proper eye protection as severe damage to the eyes can result.
  • Page 4: Operation

    OPERATION The CX3000 installs in the air-inlet side of any heating and air condi- tioning system, up to five tons in size. Operation of the air-handler fan unit is required for air purification and sterilization to take place. Note: The ultraviolet lamps are wired to operate continuously. This fea- ture allows the catalyst to burn off surface impurities, while cleaning and reactivating itself during periods of no airflow.
  • Page 5: Cycle Times

    The Air Cycler can be sourced from Shelter Supply, Lakeville, MN (1-800- 762-8399) or (www.Air Cycler.com) on the web. Electricity cost per kilowatt hour .06 kw hr. CX3000 (32.25 kw hours) per month $1.93 During periods where the fan unit is being operated for the sole purpose of air purification, running a 1/2 horsepower fan unit will add approxi- mately $5.36 per month to the normal operating cost.
  • Page 6: Service

    The CX3000 comes with a built-in computerized service panel to automati- cally keep track of service intervals. Indicator lights will tell you when to change filter and ultraviolet lamps (30) days in advance. MERV-11 Filter ..change every (6) months ..service light turns from green to yellow after five months, and to red after six months.
  • Page 7: Changing The Uv Lamps

    Remove filter as in Fig. - 1. Reach inside and rotate UV lamp 1/4 turn in either direction and remove. Fig. - 3 Carefully place new lamp back into inner case so that the pins line up with the slot on lamp holders at each end. Fig. - 4 Slide the new lamp down into the lamp holders and rotate 1/4 turn.
  • Page 8: Resetting The Service Lights

    (2) filters and (1) set of UV lamps. Replacement kits are avail- able from your local HVAC wholesaler. Make sure to install the CX3000 so that the inlet, or return air, enters the side containing the MERV-11 particle filter first. Fig. - 6 FIG.
  • Page 9 Tape all seams between the air handler and the outlet side of the CX3000 so there can be no air bypassing the system. Attach the air handler to the outlet side of the CX3000, and fasten with #10 x 3/8 self-drilling sheet metal screws. NOTE: Only 1/2 inch of clearance has been provided between the outer and inner case.
  • Page 10: Typical Vertical And Horizontal Installation

    TYPICAL VERTICAL AND HORIZONTAL INSTALLATION...
  • Page 11: Limited Lifetime Warranty

    This warranty does not cover the cost for removal or reinstal- lation of the CX3000 when service or warranty work is required. All war- ranty repair work must be performed either at the factory or by a factory certified service center.
  • Page 12: Performance Data And Approvals

    PERFORMANCE DATA AND APPROVALS Air Flow (cfm) Air flow & Resistance Data CX3000 Resistance (in w.g.) 1250 0.18 1500 0.20 1750 0.25 2000 0.35 2250 0.42 2500 0.55 Air Velocity (fpm)
  • Page 13: Wiring Diagram

    WIRING DIAGRAM CX3000...
  • Page 14: Parts List

    AL002 CD009 HD002 HD067 HD073 HD074 MT013 MT043 FS000 PARTS LIST CX3000 DESCRIPTION 120 V 60 Hz. 420MA Ballast 120V 60Hz 12V 1-Amp Transform Electron Terminal Block CFM Embossed Label Duct Display Board Duct Control Cover Fuse Holder Fuse Duct Electrical Receptacle...
  • Page 15: Cx3000 Exploded View

    EXPLODED VIEW CX3000...
  • Page 16 Continental Fan Manufacturing Inc. 203 Eggert Road Buffalo, New York 14215 Tel: 800-779-4021 Fax: 716-842-0611 email: cfm@continentalfan.com web: www.continentalfan.com...