SPX Hankinson HHE Series Instruction Manual page 42

Pressure-swing desiccant type compressed air dryers with accushift switching valves
Table of Contents

Advertisement

Dryer MOP
ISO Class
Dew Point
Cycle Time (minutes)
Time
t0
t1
t2
t3
t4
t5
t6
t7
t8
Purge time (min:sec)
[(t3-t2) or (t7-t6)]
Repress. time (min:sec)
[(t4-t3) or (t8-t7)]
NOTE: When operated in the Demand Mode, drying times t4-t0 and t8-t4 can extend to a maximum of 30 minutes each. Purge times in the
Demand Mode, regardless of the ISO Class selection, will always be equal to the purge times of the ISO Class 2 (10 min.) Fixed Cycle (3:54 for
150 psig MOP and 2:54 for 250 psig MOP).
60 - 150 psig (4.1 - 10.3 barg)
1
2
-73°C
-40°C
-20°C
-100°F
-40°F
-4°F
4
10
Time from start of cycle
(minutes : seconds)
00:00
00:00
00:00
00:02
00:02
00:02
00:06
00:06
00:06
01:12
04:00
06:55
02:00
05:00
08:00
02:02
05:02
08:02
02:06
05:06
08:06
03:12
09:00
14:55
04:00
10:00
16:00
Reference Data
01:06
03:54
06:49
00:48
01:00
01:05
Fixed Cycle Timing – Level 2 Controller
— 40 —
3
4
1
+3°C
-73°C
+38°F
-100°F
16
24
4
00:00
00:00
00:02
00:02
00:06
00:06
10:50
00:48
12:00
02:00
12:02
02:02
12:06
02:06
22:50
02:48
24:00
04:00
10:44
00:42
01:10
01:12
Table 8-3
120 - 250 psig (8.3 - 17.2 barg)
2
3
-40°C
-20°C
-40°F
-4°F
10
16
Time from start of cycle
(minutes : seconds)
00:00
00:00
00:02
00:02
00:06
00:06
03:00
05:40
05:00
08:00
05:02
08:02
05:06
08:06
08:00
13:40
10:00
16:00
02:54
05:34
02:00
02:20
4
+3°C
+38°F
24
00:00
00:02
00:06
09:20
12:00
12:02
12:06
21:20
24:00
09:14
02:40

Hide quick links: