Whisper Power M-GV/2 User Manual

Whisper Power M-GV/2 User Manual

Genverters for marine use
Hide thumbs Also See for M-GV/2:
Table of Contents

Advertisement

Quick Links

M-GV/2, M-GV/3, M-GV/3+,
M-GV 8, M-GV 10, M-GV 12 and M-GV 15
genverters for marine use
WHISPERPOWER BV
Kelvinlaan 82
9207 JB Drachten
Netherlands
Tel.: +31-512-571550
Fax.: +31-512-571599
www.whisperpower.com
V1.2,May 2018

Advertisement

Table of Contents
loading

Summary of Contents for Whisper Power M-GV/2

  • Page 1 M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 genverters for marine use WHISPERPOWER BV Kelvinlaan 82 9207 JB Drachten Netherlands Tel.: +31-512-571550 Fax.: +31-512-571599 www.whisperpower.com V1.2,May 2018...
  • Page 2: Table Of Contents

    Engine ....................................17 5.3.1 Preliminary instructions ........................... 17 5.3.2 Bleeding the fuel lines............................17 Regular maintenance................................17 5.4.1 General precautions ............................17 5.4.2 Servicing after break-in ............................ 18 M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 3 Troubleshooting table for engine ........................21 6.2.3 Warnings ................................24 6.2.4 Service address ..............................24 SPARE PARTS .................................... 25 Maintenance log ....................................26 Declaration of Conformity/Incorporation M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 4: Introduction

    For service and reinstallation. There is no cover for labour needed to get access maintenance, turn to the manufacturer or a dealer. M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 5: Liability

    Check the settings serial number. Using this number, the manufacturer can trace when there is any doubt. the specifications of the genverter. M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 6: General Information

    When service has to be carried out while the the genverter indicating danger. engine is running, be aware of moving parts. The genverter should be operated by authorized personnel only. M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 7: Fire And Explosion

    All cables temperatures in excess of 315°C an extremely corrosive acid is and hoses are guided through the enclosure M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 8: Control

    Installation accessories are listed in the installation manual and are available through the supplier of the genverter. M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 9: Main Components To Identify

    11. oil filler cap 12. thermostat cover 13. V-belt 14. stop lever 15. speed control lever Figure 2: M-GV/2 and M-GV 8, M-GV/3 and M-GV 10, service side 1. exhaust temperature switch (behind panel) 2. starter 3. oil pressure switch 4.
  • Page 10: M-Gv/3+, M-Gv 12 And M-Gv 15

    3. oil pressure switch 4. alternator 5. air filter 6. Permanent Magnet Alternator 7. earth lug 8. exhaust Figure 5: M-GV/3+, M-GV 12 and M-GV 15, reverse view M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 11: Technical Information

    Pushing the STOP button will stop the engine and the electrical system will be deactivated. When using the M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 12: Biodiesel

    When the engine is on temperature the liquid will expand and the redundant liquid will be pressed into the expansion tank. This tank has to be filled up till the mark. M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 13: Technical Data

    Start/stop & maintenance Service interval oil change 200 h Lubricant At least CF Oil capacity Approx. 2.5 l Approx. 3.8 l Approx. 5.1 l (continued on next page) M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 14 Automotive EMC 2004/104/EC EN (designed to meet) EN 60945 ABYC (designed to meet) American Boat & Yacht Council UL or CSA (designed to meet) UL 458 M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 15: Operation

    Whisper Switch of Transfer System Switch is installed, this Switch off all devices. operates automatically. Switch on the battery switch (when installed). Switch on battery switch (if installed). Fuel valve: open. M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 16 (2-3 hours) only! The high peak current is M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 17: Maintenance

    For the same reason it is of the greatest importance to use measures have to be taken to prevent oil from being spilled. the right oil specification. M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 18: Servicing After Break-In

    Figure 10: Alternator belt (similar on all models) cool down sufficiently to allow safe working. Drain oil through the dipstick hole using a vacuum pump as commonly used in garages. M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 19: Draining Water From The Fuel Tank

    This method of preservation will be sufficient for 6 months. but should be done at least every 400 running hours. A clogged Change before using engine again. M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 20: Troubleshooting

    650 V. Remove 3 A fuse from the control panel while working on the genverter in order to prevent the engine from starting. M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 21: Troubleshooting Table For Alternator

    Starter is turning engine smoothly, Fill up with fuel or replace with better quality Out of fuel or faulty fuel, water in the but engine fails to start fuel M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 22 Faulty actuator advice Genverter must be sent to manufacturer for repair Defective alternator (windings or other) of damaged bearing or winding Repair by WhisperPower service Damaged engine M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 23 When in doubt, measure the power directly using an appropriate instrument. M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 24: Warnings

    If you cannot correct a problem with the aid of the troubleshooting tables, contact your WhisperPower Service Centre or WhisperPower Netherlands for an extended service list. Phone: INT +31-512-571555. M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 25: Spare Parts

    Fuel pump (high pressure) complete 40403160 40404160 40201680 Thermostat (**) 40403145 40403145 40403145 Thermostat gasket (**) 40403138 40403138 40403138 Rocker cover gasket (**) 40403137 40404137 40201637 M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 26: Maintenance Log

    2000 h 2200 h 2400 h 1,2,3 2600 2800 h 3000 h 3200 h 1,2,3,4 3400 h 3600 h 3800 h 4000 h 1,2,3 4200 h M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 27 6800 h 7000 h 7200 h 1,2,3 7400 h 7600 h 7800 h 8000 h 1,2,3,4 8200 h 8400 h 8600 h 8800 h 1,2,3 9000 h M-GV/2, M-GV/3, M-GV/3+, M-GV 8, M-GV 10, M-GV 12 and M-GV 15 May 2018...
  • Page 28 Supplier's Declaration of Conformity/Incorporation 7015001001 Issuer's name: WhisperPower BV Issuer's address: Kelvinlaan 82, NL-9207 JB Drachten Object of the declaration: WhisperPower two and three cylinder genverters, model nos. 41001105, 41005005, 41005006, 41005030, 41001305, 41009005, 41009006, 41009030, 41006005, 41006006, 41006030, 41001505, 41007005, 41007055, all serial nos. The object of the declaration described above is in conformity with the requirements of the following Directives and standards, as applicable: Document...
  • Page 29 OTHER PRODUCTS FROM WHISPERPOWER WhisperPower offers a wide range of power-related products. In our PowerBook, these are arranged as follows. Power Generation - Genverter - 3000 rpm - 1500 rpm Power Conversion Power Storage -ion batteries -related products Power Distribution Hybrid power systems for power generation &...
  • Page 32 Kelvinlaan 82, 9207 JB Drachten, Netherlands Tel : + 31-512-571550 / Fax : + 31-512-571599 www.whisperpower.com / info@whisperpower.com...

Table of Contents