CBA38MV-030 BLOWER PERFORMANCE
0 through 0.80 in. w.g. External Static Pressure Range
"ADJUST"
Jumper
Setting
+
NORM
NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.
First stage cooling air volume is 70% of COOL speed setting. Continuous fan speed is approximately 28%, 38%, 70% and 100% (Jumper selectable) of the
same second-stage COOL speed selected, minimum 250 cfm.
Lennox iHarmony
Zoning System applications - minimum blower speed is 250 cfm.
®
CBA38MV-036 BLOWER PERFORMANCE
0 through 0.80 in. w.g. External Static Pressure Range
"ADJUST"
Jumper
Setting
+
NORM
NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.
First stage cooling air volume is 70% of COOL speed setting. Continuous fan speed is approximately 28%, 38%, 70% and 100% (Jumper selectable) of the
same second-stage COOL speed selected, minimum 250 cfm.
Lennox iHarmony
Zoning System applications - minimum blower speed is 250 cfm.
®
CBA38MV-042 BLOWER PERFORMANCE
0 through 0.80 in. w.g. External Static Pressure Range
"ADJUST"
Jumper
Setting
+
NORM
NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.
First stage cooling air volume is 70% of COOL speed setting. Continuous fan speed is approximately 28%, 38%, 70% and 100% (Jumper selectable) of the
same second-stage COOL speed selected, minimum 450 cfm.
Lennox iHarmony
Zoning System applications - minimum blower speed is 450 cfm.
®
CBA38MV-048 BLOWER PERFORMANCE
0 through 0.80 in. w.g. External Static Pressure Range
"ADJUST"
Jumper
Setting
+
NORM
NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.
First stage cooling air volume is 70% of COOL speed setting. Continuous fan speed is approximately 28%, 38%, 70% and 100% (Jumper selectable) of the
same second-stage COOL speed selected, minimum 450 cfm.
Lennox iHarmony
Zoning System applications - minimum blower speed is 450 cfm.
®
"HEAT" Speed
1
2
cfm
cfm
660
880
1100
600
800
1000
540
720
"HEAT" Speed
1
2
cfm
cfm
900
1225
1380
810
1125
1275
730
1000
1135
"HEAT" Speed
1
2
cfm
cfm
1100
1320
1540
1000
1200
1400
900
1080
1260
"HEAT" Speed
1
2
cfm
cfm
1625
1820
2055
1425
1625
1805
1205
1375
1555
Jumper Speed Positions
3
4
cfm
cfm
cfm
1320
660
1200
600
900
1080
540
Jumper Speed Positions
3
4
cfm
cfm
cfm
1545
900
1400
810
1265
730
Jumper Speed Positions
3
4
cfm
cfm
cfm
1760
1100
1600
1000
1440
900
Jumper Speed Positions
3
4
cfm
cfm
cfm
2145
1625
2005
1425
1725
1205
Page 16
"COOL" Speed
1
2
3
cfm
cfm
880
1100
800
1000
720
900
"COOL" Speed
1
2
3
cfm
cfm
1225
1380
1125
1275
1000
1135
"COOL" Speed
1
2
3
cfm
cfm
1320
1540
1200
1400
1080
1260
"COOL" Speed
1
2
3
cfm
cfm
1820
2055
1625
1805
1375
1555
4
cfm
1320
1200
1080
4
cfm
1545
1400
1265
4
cfm
1760
1600
1440
4
cfm
2145
2005
1725