Target CFM Tables

CBX32MV-018/024 BLOWER PERFORMANCE
0 through 0.80 in. w.g. External Static Pressure Range
"ADJUST"
Jumper
Setting
+
NORM
NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.
First stage cooling air volume is 70% of COOL speed setting. Continuous fan speed is approximately 28%, 38%, 70% and 100% (Jumper selectable) of the
same second-stage COOL speed selected, minimum 250 cfm.
Lennox iHarmony
Zoning System applications - minimum blower speed is 250 cfm.
®
CBX32MV-024/030 BLOWER PERFORMANCE
0 through 0.80 in. w.g. External Static Pressure Range
"ADJUST"
Jumper
Setting
+
NORM
NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.
First stage cooling air volume is 70% of COOL speed setting. Continuous fan speed is approximately 28%, 38%, 70% and 100% (Jumper selectable) of the
same second-stage COOL speed selected, minimum 250 cfm.
Lennox iHarmony
Zoning System applications - minimum blower speed is 250 cfm.
®
CBX32MV-036 BLOWER PERFORMANCE
0 through 0.80 in. w.g. External Static Pressure Range
"ADJUST"
Jumper
Setting
+
NORM
NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.
First stage cooling air volume is 70% of COOL speed setting. Continuous fan speed is approximately 28%, 38%, 70% and 100% (Jumper selectable) of the
same second-stage COOL speed selected, minimum 250 cfm.
Lennox iHarmony
Zoning System applications - minimum blower speed is 250 cfm.
®
CBX32MV-048 and cbx32MV-060 BLOWER PERFORMANCE
0 through 0.80 in. w.g. External Static Pressure Range
"ADJUST"
Jumper
Setting
+
NORM
NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.
First stage cooling air volume is 70% of COOL speed setting. Continuous fan speed is approximately 28%, 38%, 70% and 100% (Jumper selectable) of the
same second-stage COOL speed selected, minimum 450 cfm.
Lennox iHarmony
Zoning System applications - minimum blower speed is 450 cfm.
®
"HEAT" Speed
1
2
cfm
cfm
715
855
1000
670
770
580
700
"HEAT" Speed
1
2
cfm
cfm
800
935
1070
725
850
655
765
"HEAT" Speed
1
2
cfm
cfm
1230
1335
1445
1120
1215
1315
1010
1185
1200
"HEAT" Speed
1
2
cfm
cfm
1850
1960
2090
1705
1800
1900
1560
1625
1720
Jumper Speed Positions
3
4
cfm
cfm
cfm
1130
465
900
1035
425
800
930
385
Jumper Speed Positions
3
4
cfm
cfm
cfm
1210
660
975
1100
600
880
990
540
Jumper Speed Positions
3
4
cfm
cfm
cfm
1545
900
1400
810
1265
730
Jumper Speed Positions
3
4
cfm
cfm
cfm
2150
1625
2005
1425
1770
1205
Page 13
"COOL" Speed
1
2
3
cfm
cfm
690
900
620
825
560
735
"COOL" Speed
1
2
3
cfm
cfm
880
1100
800
1000
720
900
"COOL" Speed
1
2
3
cfm
cfm
1225
1380
1125
1275
1000
1135
"COOL" Speed
1
2
3
cfm
cfm
1820
2055
1625
1805
1375
1555
4
cfm
1050
950
850
4
cfm
1320
1200
1080
4
cfm
1545
1400
1265
4
cfm
2145
2005
1725