This manual contains specifi c cautionary statements relative to worker safety. Read this manual thoroughly and follow
as directed. It is impossible to list all the hazards of dust control equipment. All persons involved with the equipment or
systems should be instructed how to operate in a safe manner.
This is the safety alert symbol. It is used to alert you to potential personal injury
!
hazards. Obey all safety messages that follow this symbol to avoid possible injury
or death.
Installation and Operation Manual
MODEL FRP
DUST
COLLECTOR

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FRP and is the answer not in the manual?

Questions and answers

Summary of Contents for MICRO-AIR FRP

  • Page 1 MODEL FRP DUST COLLECTOR Installation and Operation Manual This manual contains specifi c cautionary statements relative to worker safety. Read this manual thoroughly and follow as directed. It is impossible to list all the hazards of dust control equipment. All persons involved with the equipment or systems should be instructed how to operate in a safe manner.
  • Page 2: Table Of Contents

    MICRO AIR ® CLEAN AIR SYSTEMS TABLE OF CONTENTS CAUTIONS SPECIFICATIONS INSTALLATION INSPECTION CODES SET-UP ACCESSORY INSTALLATION DUST COLLECTION HOPPER DUST COLLECTION TRAY BARREL LID TOP MOUNTED BLOWER REAR MOUNTED BLOWER SHROUD REAR MOUNTED SILENCER OR HEPA MAGNEHELIC GAUGE PHOTOHELIC GAUGE COMPRESSED AIR INSTALLATION ELECTRICAL INSTALLATION 10-11...
  • Page 3: Cautions

    MICRO AIR ® CLEAN AIR SYSTEMS WARNING The installation/operation manual must be read and followed in its entirety. Process owners/operators have important responsibilities relating to combustible hazards. Process owners/operators must determine whether their process creates combustible dust, fume, or mist. If combustible dust, fumes, or mist is generated, process owners/operators should at a minimum: •...
  • Page 4: Specifications

    MICRO AIR ® CLEAN AIR SYSTEMS MODEL FRP SPECIFICATIONS CABINET DIMENSIONS: FRP4 72” H x 53” W x 48” D FRP6 92” H x 53” W x 48” D FRP6-2 94” H x 95” W x 48” D FRP6-3 94” H x 136” W x 48” D FRP8 112”...
  • Page 5: Installation

    MICRO AIR ® CLEAN AIR SYSTEMS INSTALLATION: INSPECTION: The Micro Air dust collector is shipped on one or more skids. All skids should be inspected for any visible damage that may have occurred during shipment. Report any damage to the delivery carrier. CODES: Codes may regulate recirculating fi...
  • Page 6 MICRO AIR ® CLEAN AIR SYSTEMS 4. When supplied, bolt on angle braces with provided a. Apply self-adheasive foam on the bolt hole fl ange hardware (Figure 5). Ensure each leg is plumb before of the inlet plenum. tightening the bolts. b.
  • Page 7: Accessory Installation

    MICRO AIR ® CLEAN AIR SYSTEMS ACCESSORY INSTALLATION: BARREL LID 1. Bolt adapter plate and hopper adapter to the hopper DUST COLLECTION HOPPER using the four sets of 3/8” hardware (Figure 9). 1. Apply self-adheasive foam to the bolt hole fl ange on 2.
  • Page 8: Top Mounted Blower

    MICRO AIR ® CLEAN AIR SYSTEMS TOP MOUNTED BLOWER 4. Apply the self-adheasive foam to the vertical braces as 1. Apply self-adheasive foam to the bottom side of the shown in Figure 11. blower fl ange (Figure 10). 5. Re-install the motor shroud around the motor and 2.
  • Page 9: Magnehelic Gauge

    MICRO AIR ® CLEAN AIR SYSTEMS PHOTOHELIC GAUGE 1. Mount the photohelic gauge into the photohelic mounting bracket following the mounting instructions contained in the photohelic packaging. 2. Mount the two male barb fi ttings in the pressure ports Exhaust Grille located on the side of the photohelic gauge.
  • Page 10: Compressed Air Installation

    MICRO AIR ® CLEAN AIR SYSTEMS COMPRESSED AIR INSTALLATION: Set Screw Power Connection The compressed air inlet for the Roto-Pulse cleaning Pressure Switch system is at the top of the surge tank located on the side of the unit (Figure 15). A minimum of a 3/4 inch diameter line and clean, dry compressed air at a pressure of 80 psi to 90 psi is required for proper operation of the Roto-pulse cleaning system.
  • Page 11: Unit Operation

    MICRO AIR ® CLEAN AIR SYSTEMS 4. Wire from the Overload T1, T2, and T3 to the motor 1. For proper cleaning, the compressed air pressure should electrical housing. Wire size should be the same as be regulated at 80 psi to 90 psi. step 3.
  • Page 12: After-Pulse Cleaning Timer Adjustments

    MICRO AIR ® CLEAN AIR SYSTEMS Note: While this time can be adjusted it is recommended that you leave the “ON TIME” at the factory setting. If less cleaning is needed you should increase the time between pulses as a means of reducing the amount of cleaning.
  • Page 13: Pulse Control Only Wiring Schematics

    MICRO AIR ® CLEAN AIR SYSTEMS FRP4 PULSE CONTROL ONLY WIRING DIAGRAM...
  • Page 14 MICRO AIR ® CLEAN AIR SYSTEMS FRP6 PULSE CONTROL ONLY WIRING DIAGRAM...
  • Page 15 MICRO AIR ® CLEAN AIR SYSTEMS FRP8 PULSE CONTROL ONLY WIRING DIAGRAM...
  • Page 16 MICRO AIR ® CLEAN AIR SYSTEMS FRP6-2 PULSE CONTROL ONLY WIRING DIAGRAM...
  • Page 17 MICRO AIR ® CLEAN AIR SYSTEMS FRP6-3 PULSE CONTROL ONLY WIRING DIAGRAM...
  • Page 18 MICRO AIR ® CLEAN AIR SYSTEMS FRP8-2 PULSE CONTROL ONLY WIRING DIAGRAM...
  • Page 19 MICRO AIR ® CLEAN AIR SYSTEMS FRP8-3 PULSE CONTROL ONLY WIRING DIAGRAM...
  • Page 20 MICRO AIR ® CLEAN AIR SYSTEMS FRP8-4 PULSE CONTROL ONLY WIRING DIAGRAM...
  • Page 21: Full Control Wiring Schematics

    MICRO AIR ® CLEAN AIR SYSTEMS FRP4 FULL CONTROL WIRING DIAGRAM...
  • Page 22 MICRO AIR ® CLEAN AIR SYSTEMS FRP6 FULL CONTROL WIRING DIAGRAM...
  • Page 23 MICRO AIR ® CLEAN AIR SYSTEMS FRP8 FULL CONTROL WIRING DIAGRAM...
  • Page 24 MICRO AIR ® CLEAN AIR SYSTEMS FRP6-2 FULL CONTROL WIRING DIAGRAM...
  • Page 25 MICRO AIR ® CLEAN AIR SYSTEMS FRP6-3 FULL CONTROL WIRING DIAGRAM...
  • Page 26 MICRO AIR ® CLEAN AIR SYSTEMS FRP8-2 FULL CONTROL WIRING DIAGRAM...
  • Page 27 MICRO AIR ® CLEAN AIR SYSTEMS FRP8-3 FULL CONTROL WIRING DIAGRAM...
  • Page 28 MICRO AIR ® CLEAN AIR SYSTEMS FRP8-4 FULL CONTROL WIRING DIAGRAM...
  • Page 29: Cabinet Parts List

    MICRO AIR ® CLEAN AIR SYSTEMS FRP CABINET PARTS LIST FIGURE 19 ITEM PART DESCRIPTION ITEM PART DESCRIPTION 36720-13 Filter Support Assembly (Roto-Pulse) P2921 DPDT Relay Washer (Supplied with fi lter) P1754 Transformer P3649 4-Prong Knob P3910 Contactor P7400RM 80/20 Cartridge Filter...
  • Page 30: Electrical Parts List

    MICRO AIR ® CLEAN AIR SYSTEMS FRP ELECTRICAL PARTS LIST FIGURE 20 FIGURE 21...
  • Page 31: Roto Parts List

    MICRO AIR ® CLEAN AIR SYSTEMS FRP ROTO PARTS LIST FIGURE 22 FRP DOOR PARTS LIST FIGURE 23...
  • Page 32 MICRO AIR ® CLEAN AIR SYSTEMS THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 33 MICRO AIR ® CLEAN AIR SYSTEMS INSTALLATION NOTES: Date of Installation: Installer: Voltage: L1-L2 L2-L3 L3-L1 Amp Draw: Air Pressure: L2815 9/18...

Table of Contents