  • Page 1 Oilburner RG3D Code No.: 970930...
  • Page 2: Oil Burner

    Instruction Oilburner Type Gulliver RG3D This instruction should be kept in the furnace room The user is responsible for the burners working order and that the following points are observed. Please check before ignition: Interruptions: – that the valves on the oil pipes are open –...
  • Page 3: Technical Instructions

    Technical instructions Oilbuner Type Gulliver RG3D Main components of the oilburner, dimensions Type 394 T1 Terminal power – output 68/88 – 188,5 kW (H ) (5,4/7,0 – 15 kg/h) Fuel Viscosity max. 6 mm /s (1,5° E) at 20° C...
  • Page 4: Burner Start-Up Cycle

    Technical instructions Oilburner Type Gulliver RG3D Capacity diagram, start-up cycle In the capasity diagram below the burner maximum preformance (Bmax) is in proportion to the positive pressure of the combustion chamber (Po). [mbar] [kW] [kg/h] Burner start-up cycle: Normal Lock-out due to failure to light...
  • Page 5 Assembling Oilbuner Type Gulliver RG3D Dimensioning of oil pipes One-line system: The pump is designed to allow working with two pipes. In order to obtain one pipe working it is necessary to unscrew the return plug (2), remove the by-pass screw (3) and then screw again the plug (2).
  • Page 6 Assembling Oilburner Type Gulliver RG3D Dimensioning of the oil pipes One-line system: On the tank installa- tion, where vacuum can occur in the oil tubes, you install a flow-control between the front filter and the oil burner. The pump suction should not exceed a maximum of 0.4 bar (30 cm Hg).
  • Page 7 Assembling Oilbuner Type Gulliver RG3D Cables and control box Electrical wiring: El cable (min. 1 mm ) with 7-pin plug Wieland plug on the burners control box. The control box has intern 230 V/5 Amp. fuse (B). If the fuse should be defect the oil burner will not...
  • Page 8 Adjustment Oilburner Type Gulliver RG3D Accessibility to the nozzle: Remove nozzle-holder assembly (1) after loosing screws (2) and nut (3), remove the small cables (4) from the control box, the photoresistance (6). Withdraw the small cables (4) from the electrodes, remove the diffuser disc-hol- der assembly from the nozzle-holder as- sembly (1) after loosing screw (3, fig.
  • Page 9: Combustion Adjustment

    Adjustment Oilbuner Type Gulliver RG3D Combustion adjustment: To suit the required appliance output, fit the nozzle then adjust the pump pressure, and the air damper opening in accordance with the following schedule. Nozzles recommended: Delavan: Type W – B Danfoss: Type S –...
  • Page 10 Adjustment Oilburner Type Gulliver RG3D 1st stage adjustment Adjustment of air shutter: Unloosen the nut (1), turn the screw (2) until the indicator (3) reaches the position desired. Then lock the nut (1). Pressure regulation: This is set at 9 bar at the factory.
  • Page 11: Electrical Wiring

    Electrical wiring Oilbuner Type Gulliver RG3D Brown Blue Brown Blue Black White Black Control box Black 550 SMD Electronic delaying device T8 T7 Signaturer Electrode Motor Capacitor Needle valve Photoresistance Plug connection for internal components 7 pind plug 4 pin plug...
  • Page 12: Exploded View

    Exploded view Oilburner Type Gulliver RG3D Spare parts overview Pos. Code No Description Pos. Code No Description Cover Air damper 80002702 80007650 Electrical start delaying device 80008983 80007652 4 pin plog socket 1st stage air damper reg. 80006949 80007785 80007454...