InLine Hot Water System
Control Panel User Guide
Logicor (CH) Ltd.
Version / Issue Date: 17 Dec 2015

Advertisement

Table of Contents
loading

Summary of Contents for Logicor InLine Hot Water System

  • Page 1 InLine Hot Water System Control Panel User Guide Logicor (CH) Ltd. Version / Issue Date: 17 Dec 2015...
  • Page 2: Table Of Contents

     Cleaning ..................v INTRODUCTION ..................... 1  Control Panel .................. 2  InLine Hot Water System..............3 SECTION 1: HELP MODE ..................4  Help Mode ..................5 SECTION 2: CONTROL PANEL & HEATER SETTINGS ..........6  Control Panel & Heater Settings ..........7 ...
  • Page 3 Brightness Settings ................ 16  Recalibration ................17  Load Original Settings ..............18  InLine Hot Water System Settings ..........19  Adjust Complete System ............. 20  Adjust Zones .................. 21  Edit Zone Name & Temperature ..........22 ...
  • Page 4 Delete Water Heater Unit............31 SECTION 3: STATUS SCREEN ................32  Status Screen - Summary ............33  Status Screen - InLine Hot Water System ........34 SECTION 4: COST & ENERGY SETTINGS .............. 35  Cost & Energy Settings ..............36 ...
  • Page 5: Safety (Part 1 Of 2)

    Safety & Maintenance   The InLine Hot Water System must be installed by a WARNING - InLine Hot Water System units must not be certified installer authorized by Logicor. used if there is any visible damage to the outer case or the unit itself.
  • Page 6: Cleaning

    InLine Hot Water System units as it may persons to avoid a hazard. reduce or damage the performance and can be dangerous.
  • Page 7: Introduction

    Some options are only available if you have both a Clear each function; simply press the help icon at any time. Heater System and an InLine Hot Water System installed. Use the table of contents at the beginning of this guide...
  • Page 8: Control Panel

    Clear Heater box but you can change the settings at any time with System (CHS) and the InLine Hot Water System (ILHWS). your own preferences. The control panel is recommended by the Energy Saving Trust for its energy saving abilities.
  • Page 9: Inline Hot Water System

    MENU ► Tip! Use the menu path headings at the top of each page to help you navigate through the screens InLine Hot Water System Our new InLine Hot Water System (ILHWS) is powered by Safety features include an anti-scald valve, thermal cut...
  • Page 10: Section 1: Help Mode

    Control Panel & Heater Settings …….. (Page 6) Section 3: Status Screen ..…………......(Page 32) Section 4: Cost & Energy Settings ......(Page 35) Section 5: Timer Settings (only available with CHS ) © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 4...
  • Page 11: Help Mode

    The help icon is always there at the top left of your screen to give you additional information about the current control panel display. Pressing the screen again takes you back to your previous screen. © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 5...
  • Page 12: Section 2: Control Panel & Heater Settings

    Control Panel & Heater Settings …….. (Page 6) Section 3: Status Screen ..…………......(Page 32) Section 4: Cost & Energy Settings ......(Page 35) Section 5: Timer Settings (only available with CHS ) © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 6...
  • Page 13: Control Panel & Heater Settings

    Note: Only available with a CHS installation. panel and heater settings menu.  InLine Hot Water System (Page 19) From here you can change the main settings of your Adjust your water heating preferences for individual control panel or load the original factory settings to reset...
  • Page 14: Main Settings

    Edit which status messages appear on the main status screen or change the control panel screen brightness levels and touch-screen settings.  Frost & Fireguard Note: Only available with a CHS installation. © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 8...
  • Page 15: Wifi Settings

    Smartphone. Use the keypads to type in your settings and press the save button to store your settings. The INFO message at the top displays the current Wifi status. © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 9...
  • Page 16: Time & Date

    Time and date updates will then be automatic. - Select Degrees Centigrade. Alternatively, use the 'Country Select (Page 12)' option to Press the save button to store your settings. automatically set the correct time, date, currency and temperature units. © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 10...
  • Page 17: Tariff Settings

    Your tariff settings can be found on your utilities bill, or by contacting your service provider. Please remember to amend your tariff rate on the control panel if and when your tariff changes. © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 11...
  • Page 18: Country Select

    These are required to display and calculate your cost performance targets and the system temperature accurately. Alternatively you can change the units of temperature manually via the Time & Date screen on page 10. © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 12...
  • Page 19: Screen Options

    Choose which performance data appears on the main status screen by selecting ‘Status screen options’. Change the screen brightness and energy saving settings by selecting ‘Brightness settings’. 'Touch recalibration' allows you to fine tune the touch- screen sensitivity settings. © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 13...
  • Page 20: Status Screen Options: Choose A System

    Clear Heater System installation.  Choose InLine Hot Water System (Page 15) Choose this option to adjust the performance data readings for your InLine Hot Water System. You can choose which performance data appears on the main status screen.
  • Page 21: Status Screen Options: Choose Readings

    MENU ► Settings Icon (p. 7) / Main settings (p.8) / Screen options (p.13) / Status screen options (p.14) / InLine Hot Water System Status Screen Options: Choose Readings Options:  Choose your readings Choose from the list which performance data readings appear on the main status screen.
  • Page 22: Brightness Settings

    In sleep mode the main display screen dims to black. You can change how long (in seconds) the display is  Edit heater communication light settings active before switching off into sleep mode. Note: only available with CHS installations. © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 16...
  • Page 23: Recalibration

    13) to start the recalibration process where you’ll be asked to touch a dot at the top-left, bottom-right and middle of the screen to automatically adjust to your settings. When completed, the confirmation screen will display the results. © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 17...
  • Page 24: Load Original Settings

    Load the original settings if you want to reset the system back to the original factory settings. Once reset, you will have to re-enter all your settings and preferences again. © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 18...
  • Page 25: Inline Hot Water System Settings

    MENU ► Settings Icon (p. 7) / InLine Hot Water System (ILHWS) InLine Hot Water System Settings Options:  Complete system (Page 20) Adjust the temperature of the whole system or turn the system on or off.  Adjust zones (Page 21) A zone is a group of water heater units with the same settings.
  • Page 26: Adjust Complete System

    Press the save button to store your entry.  Turn InLine Hot Water System On or Off Select ON or OFF to turn the complete water heater system on or off. Press the save button to store your entry.
  • Page 27: Adjust Zones

    Scroll through the list to select an existing zone to adjust or press 'Add new zone' to add a new zone to the system. © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 21...
  • Page 28: Edit Zone Name & Temperature

    Give each zone a unique name and water temperature by entering the details with the keypad. Water heater units can also be assigned to a zone or the zone can be deleted from the system. © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 22...
  • Page 29: Add New Zone

    Give each zone a unique name and water temperature by entering the details with the keypad. Water heater units can also be assigned to a zone or the zone can be deleted from the system. © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 23...
  • Page 30: Assign Water Heater Units To Zone

    All water heater units assigned to a zone will then use that zone's settings. Assigned water heater units will display a tick next to the name. © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 24...
  • Page 31: Delete Zone

    Choose NO to cancel this action and return to the previous screen. Zones can be deleted from the system. Only the zone will be deleted and not the individual water heater units. Confirm your choice by selecting yes or no. © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 25...
  • Page 32: Adjust Water Heaters

    Water heater units can be set to operate individually or Select this option to manually add a new water heater in a zone. to the system. Adjust the individual settings here to give each water heater unit a unique setting. © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 26...
  • Page 33: Add New Water Heater

    Each water heater unit has a unique identification number on the underside of the base. Plug in your new heater unit and enter the heater ID number here to automatically add it to the system. © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 27...
  • Page 34: Add New Water Heater: Waiting

    Each water heater unit has a unique identification number on the underside of the base. Once you enter this number on the previous screen (Page 27), the control panel attempts to connect the new water heater unit automatically. © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 28...
  • Page 35: Add New Water Heater: Confirmation

    The results are shown on this screen. If successful you can adjust its individual settings or repeat the process to add an additional water heater unit. © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 29...
  • Page 36: Edit Water Heater Name & Temperature

    Give each water heater unit a unique name and temperature by entering the details with the keypad. Water heater units can also be assigned to a zone or deleted from the system. © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 30...
  • Page 37: Delete Water Heater Unit

    Confirm your choice on this screen by selecting YES or If you make a mistake, a water heater unit can always be added again by selecting the 'add new water heater' option on page 26. © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 31...
  • Page 38: Section 3: Status Screen

    Control Panel & Heater Settings …….. (Page 6) Section 3: Status Screen ..…………......(Page 32) Section 4: Cost & Energy Settings ......(Page 35) Section 5: Timer Settings (only available with CHS ) © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 32...
  • Page 39: Status Screen - Summary

     Select the water drop icon (Page 34) Select the Water Drop icon to access more status information about your InLine Hot Water System (if installed). The status screen displays a summary of your heater systems all in one place. The Clear Heater System (if installed) is displayed by a heater unit icon.
  • Page 40: Status Screen - Inline Hot Water System

     Select the water drop icon (Page 34) Select the Water Drop icon to access more status information about your InLine Hot Water System (if installed). The status screen displays a summary of your heater system all in one place. A Clear Heater System (if installed) is displayed by a heater unit icon.
  • Page 41: Section 4: Cost & Energy Settings

    Control Panel & Heater Settings …….. (Page 6) Section 3: Status Screen ..…………......(Page 32) Section 4: Cost & Energy Settings ......(Page 35) Section 5: Timer Settings (only available with CHS ) © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 35...
  • Page 42: Cost & Energy Settings

     Select InLine Hot Water System (Page 37) Select InLine Hot Water System to start editing your budget and energy targets for water heating. You can set your own budget and energy targets to help keep track of costs and energy usage. Choose your heater system from the list to start editing your targets.
  • Page 43: Adjust Cost & Energy Settings

    MENU ► Cost & Energy Settings (Pound) Icon (p.36) / Adjust InLine Hot Water System Adjust Cost & Energy Settings Options:  Adjust cost targets Set your targets in terms of spend per day or month.  Adjust water use targets Set your targets in terms of maximum litres of water heated per day or month.
  • Page 44: Specification: Control Panel

    Logicor Model No. Base: Chrome plated Aluminium Electric Supply: Located on the rear of the control panel, connection via CAT5 or CAT6 patch lead to a Logicor 230V ( UK, NZ, Australia ) bespoke power supply unit. The socket outlet shall be Voltage 120V ( U.S.
  • Page 45: Specification: Inline Hot Water System

    Width 500 mm No Assembly required. All InLine Hot Water Heater Systems arrive ready to install. Height 470 mm Each InLine Hot Water System is packed in a single specifically designed carton with shock protection. Depth 90 mm Weight 15kg Colour White &...
  • Page 46 © 2015 Logicor (CH) Ltd clear-heater.co.uk Page 40...
  • Page 47 MANUFACTURER: Logicor (CH) Ltd Unit 7 Thornes Office Park Monckton Road Wakefield WF2 7AN West Yorkshire UK www.logicor.co.uk www.clear-heater.co.uk...