Table of Contents

Advertisement

Quick Links

Control Panel User Guide
Logicor (CH) Ltd
Version: EN-UK-01-02-2016
Language: English

Advertisement

Table of Contents
loading

Summary of Contents for Logicor PSU 1001

  • Page 1 Control Panel User Guide Logicor (CH) Ltd Version: EN-UK-01-02-2016 Language: English...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SAFETY ................................V SÉCURITÉ ................................. VII SEGURIDAD ............................... IX INTRODUCTION ..............................1 ..............................2 ONTROL ANEL ............................3 LEAR EATER NITS SECTION 1: HELP MODE ............................4 ..............................5 SECTION 2: CONTROL PANEL & TEMPERATURE SETTINGS ................... 6 &...
  • Page 3 TABLE OF CONTENTS Status Screen Options: Choose a System ........................ 14 Status Screen Options: Choose Readings ........................ 15 Brightness Settings ..............................16 Brightness Settings - Heater Communication Light ....................17 Recalibration ................................18  Frost & Fireguard Settings ..............................19 ...
  • Page 4 TABLE OF CONTENTS  Link Heaters ..................................36 Edit Name & Temperature of Link ........................... 37 Add New Link ................................38 Modify Link ................................39 Delete Link ................................40  Adjust Heat-up Mode ................................41 Heat-up Mode - Adjust Surface Temperature ......................42 Heat-up Mode - Adjust Activation Threshold ......................
  • Page 5 TABLE OF CONTENTS SECTION 4: COST & ENERGY SETTINGS ......................55 & E ..........................56 NERGY ETTINGS  & E ..........................57 DJUST NERGY ETTINGS SECTION 5: TIMER SETTINGS ..........................58 .............................. 59 IMER ETTINGS ..............................60  EEKLY ETTINGS ...
  • Page 6: Safety

    WARNING - Do not install the Clear Heater System in a In the unlikely event of you requiring service please wardrobe or to a ceiling. contact your authorised distributor or Logicor by Our installers will advise and install your Clear Heater visiting www.logicor.co.uk.
  • Page 7 If you wish to dry clothes with the Clear Heater System Cleaning please purchase a clothes dryer system from Logicor. The Logicor clothes dryer system provides a  IMPORTANT - The temperature sensor located in the...
  • Page 8: Sécurité

    être fait sans Ne pas installer le panneau de contrôle ou unité de danger, et contactez Logicor (CH) Ltd. chauffage standard dans une salle de bain ou de la situation de la chambre humide. Pour la pose des ...
  • Page 9 Heater System veuillez acheter un système de séchoir base du radiateur est conçu pour fonctionner en à linge auprès de Logicor. Le système de séchoir à présence de poussière domestique normale. Veuillez linge Logicor offre un moyen pratique, sécurisé et éviter de vaporiser du vernis, de la laque à...
  • Page 10: Seguridad

     Clear Heater System debe ser instalado por un Heater System en la posición más eficiente para técnico certificado autorizado por Logicor. calentar su hogar de forma segura y eficaz. Nuestros técnicos deben someterse a unas estrictas normas de calidad antes de ser aptos para instalar nuestros sistemas.
  • Page 11 Logicor. químicos de spray cerca del sensor, ya que puede El sistema de secado de ropa de Logicor ofrece una reducir o dañar el rendimiento. Utilice un paño seco manera rápida, segura y práctica de secar sus...
  • Page 12: Introduction

    MENU ► headings at the top of the page to go direct to Section 5: that page. Timer Settings……………......(Page 58) Check out our website www.clear-heater.co.uk for product updates. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 1...
  • Page 13: Control Panel

    A Logicor approved installer will be named zones (e.g. all bedrooms). needed to carry out your installation to ensure the heater units are positioned to achieve optimal heating.
  • Page 14: Clear Heater Units

    We are so confident in our heater system that we give you 20 years guarantee on all heater units with a life expectancy of over 33 years. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 3...
  • Page 15: Section 1: Help Mode

    Help Mode………………………....(Page 4) Section 2: Control Panel & Temperature Settings (Page 6) Section 3: Status Screen……………......(Page 53) Section 4: Cost & Energy Settings…......(Page 55) Section 5: Timer Settings……………......(Page 58) © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 4...
  • Page 16: Help Mode

    The help icon is always there at the top left of your screen to give you additional information about the current control panel display. Pressing the screen again takes you back to your previous screen. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 5...
  • Page 17: Section 2: Control Panel & Temperature Settings

    Help Mode………………………....(Page 4) Section 2: Control Panel & Temperature Settings (Page 6) Section 3: Status Screen……………......(Page 53) Section 4: Cost & Energy Settings…......(Page 55) Section 5: Timer Settings……………......(Page 58) © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 6...
  • Page 18: Control Panel & Temperature Settings

    AVISO: Por favor, lea el apartado de seguridad. options.  InLine Hot Water System (Page 51) Set up your ILHWS if installed. Restricted mode Off (Page 52)  Safety feature when power supply is unstable. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 7...
  • Page 19: Main Settings

    Frostguard will turn on a heater in any room if the temperature falls below 3 °C. Fireguard warns you if a heater unit detects a higher than expected temperature in the room. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 8...
  • Page 20: Wifi Settings

    Smartphone. Use the keypads to type in your settings and press the save button to store your settings. The INFO message at the top displays the current Wifi status. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 9...
  • Page 21: Time & Date

    Once set, you should not need to adjust the time and date again if your control panel is connected to the internet. Time and date updates will then update automatically. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 10...
  • Page 22: Tariff Settings

    Your electricity and metered water charge tariffs are option on page 12. required if you have the ILHWS installed. Please remember to amend your tariff rate on the control panel if and when your tariff changes. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 11...
  • Page 23: Country Select

    Summer and winter times are updated automatically. If necessary you can manually adjust the time zone in 1 hour increments by tapping above or below the time zone on screen. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 12...
  • Page 24: Screen Options

    Choose which performance data appears on the main status screen by selecting ‘Status screen options’. Change the screen brightness and energy saving settings by selecting ‘Brightness settings’. 'Touch recalibration' allows you to fine tune the touch- screen sensitivity settings. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 13...
  • Page 25: Status Screen Options: Choose A System

    You can choose which performance data appears on the main status screen on your control panel. First choose your heater system from the list. If you only have one heater system available only one option will be listed. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 14...
  • Page 26: Status Screen Options: Choose Readings

    Once your choice is selected it will display a tick next to the item and will be displayed on the main status screen. The status screen is reached by pressing the ‘Home’ Icon. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 15...
  • Page 27: Brightness Settings

    In sleep mode the main display screen dims to black. You can change how long (in seconds) the display is  Edit heater communication light settings (Page 17 ) active before switching off into sleep mode. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 16...
  • Page 28: Brightness Settings - Heater Communication Light

    CE standard or faulty electric Remember to switch the communication light function appliances plugged in and causing interference near to on again after the cause of the communication a plugged-in heater unit. interruption has ended.. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 17...
  • Page 29: Recalibration

    13) to start the recalibration process where you’ll be asked to touch a dot at the top-left, bottom-right and middle of the screen to automatically adjust to your settings. When completed, the confirmation screen will display the results. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 18...
  • Page 30: Frost & Fireguard Settings

    Frostguard turns on a heater in any room if the room temperature falls below 3°C regardless of the individual heater settings. Frostguard will be prevented if heating goes beyond the spend limits set by the user. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 19...
  • Page 31: Load Original Settings

    Once reset, you will have to re-enter all your settings and preferences again. This does not affect any safety parameters which are not user accessible. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 20...
  • Page 32: Clear Heater System Settings

    The normal surface temperature of a heater unit during operation is 70°C (158 °F). You can change this for your own heating environment; a lower temperature in a child's bedroom for example. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 21...
  • Page 33: Adjust Complete System

    You can also turn the system on and off. Leave the system on if you want the control panel to optimise your heating for you. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 22...
  • Page 34: Adjust Zones

    Control Panel only when you need it. system. Scroll through the list to select an existing zone to adjust or press 'Add new zone' to add a new zone to the system. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 23...
  • Page 35: Adjust Independent Zone

    Edit the ON time duration in minutes and turn the Independent Zone on by using the control panel touch screen options on this display. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 24...
  • Page 36: Independent Zone Switched On

    Status Screen (Page 54)by adding the 'I-Zone cost' option from the Status Screen Options menu (Page 15). © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 25...
  • Page 37: Edit Zone Name & Temperature

    Give each zone a unique name and temperature by entering the details with the keypad. Heater units can also be assigned to a zone or the zone can be deleted from the system. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 26...
  • Page 38: Add New Zone

    Give each zone a unique name and temperature by entering the details with the keypad. Heater units can also be assigned to a zone or the zone can be deleted from the system. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 27...
  • Page 39: Assign Heater Units To Zone

    Assigned heater units will display a tick next to the name. Note: Heater units can only be assigned to one zone at a time. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 28...
  • Page 40: Delete Zone

    Choose NO to cancel this action and return to the previous screen. Zones can be deleted from the system. Only the zone will be deleted and not the individual heater units. Confirm your choice with yes or no. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 29...
  • Page 41: Adjust Heaters

    Select this option to manually add a new heater to or linked together with other heaters to work as one unit. the system. Adjust the individual settings here to give each heater unit a unique setting. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 30...
  • Page 42: Add New Heater

    Each heater unit has a unique identification number on the underside of the base. Plug in your new heater unit and enter the heater ID number here to automatically add it to the system. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 31...
  • Page 43: Add New Heater: Waiting

    Each heater unit has a unique identification number on the underside of the base. Once you enter this number on the previous screen (Page 31), the control panel attempts to connect the new heater unit automatically. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 32...
  • Page 44: Add New Heater: Confirmation

    The results are shown on this screen. If successful you can adjust its individual settings or repeat the process to add an additional new heater unit. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 33...
  • Page 45: Edit Heater Name & Temperature

    Give each heater unit a unique name and temperature by entering the details with the keypad. Heater units can also be assigned to a zone or deleted from the system. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 34...
  • Page 46: Delete Heater Unit

    YES or NO. If you make a mistake, a heater unit can always be added again by selecting the 'add new heater' option on page 30. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 35...
  • Page 47: Link Heaters

    Linked heater units can still operate within a zone by adding the individual heater units to a zone. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 36...
  • Page 48: Edit Name & Temperature Of Link

    Give linked heaters a unique name and temperature by entering the details with the keypad. Linked heaters can also be modified by adding or removing heater units or a link can be deleted from the system completely. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 37...
  • Page 49: Add New Link

    Give your new link a unique name and temperature by entering the details with the keypad. Linked heaters can also be modified by adding or removing heater units or a link can be deleted from the system. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 38...
  • Page 50: Modify Link

    All linked heater units then operate as if they were one unit. Selected heater units will display a tick next to the name. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 39...
  • Page 51: Delete Link

    Named links can be deleted from the system. Only the link between heater units will be deleted and not the individual heater units. Confirm your choice with yes or no. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 40...
  • Page 52: Adjust Heat-Up Mode

    The default threshold is if 20% of the system is below 0.9°C of target temperature. All heaters then heat up to compensate for and quickly achieve optimal temperature but this does use more energy. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 41...
  • Page 53: Heat-Up Mode - Adjust Surface Temperature

    Decreasing the normal surface temperature during heat- up may be considered safer where lower surface temperatures are preferred; in a child’s bedroom or with elderly or vulnerable people for example. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 42...
  • Page 54: Heat-Up Mode - Adjust Activation Threshold

    (page 44). Tip: Note: This product is for indoor use only You may also override Heat-up mode to switch off the function for the next eleven days (page 44). © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 43...
  • Page 55: Heat-Up Mode Override - Activation

    You may override (or switch off) Heat Up mode for eleven days to prevent the heaters entering heat up mode. Note: This product is for indoor use only © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 44...
  • Page 56: Heat-Up Mode Override - Deactivate

    You may override (or switch off) Heat Up mode for eleven days to prevent the heaters entering heat up mode. Note: This product is for indoor use only © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 45...
  • Page 57: Heater Surface Temperature

    Increase the normal surface temperature in a particularly cold environment. Decrease the normal surface temperature where it may be considered safer to have lower surface temperatures; in a child’s bedroom or with elderly or vulnerable people for example. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 46...
  • Page 58: Clear Heater Clothes Dryer

    WARNING: Do not cover. Choose this option to start the drying process. The drying status and time remaining are displayed at AVERTISSEMENT : Ne pas couvrir. the bottom of the screen. ADVERTENCIA: No cubrir. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 47...
  • Page 59: Select Clear Heater

    Clothes Dryer menu screen (Page 47). WARNING: Please read Safety Section. ATTENTION: Veuillez lire la section sécurité. AVISO: Por favor, lea el apartado de seguridad. WARNING: Do not cover. AVERTISSEMENT : Ne pas couvrir. ADVERTENCIA: No cubrir. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 48...
  • Page 60: Adjust Drying Time

    WARNING: Please read Safety Section. duration. ATTENTION: Veuillez lire la section sécurité. AVISO: Por favor, lea el apartado de seguridad. WARNING: Do not cover. AVERTISSEMENT : Ne pas couvrir. ADVERTENCIA: No cubrir. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 49...
  • Page 61: Start Drying

    AVERTISSEMENT : Ne pas couvrir. The screen then switches back to the main Clothes ADVERTENCIA: No cubrir. Dryer menu screen (Page 47) and the status message at the bottom of the screen displays the drying status. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 50...
  • Page 62: Inline Hot Water System Settings

    The InLine Hot Water System settings can be adjusted from this screen if you have the system installed and set up. All InLine Hot Water System settings are covered in a separate user guide. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 51...
  • Page 63: Restricted Mode Off

    MENU ► Cog Icon (p. 7) / Restricted mode off Restricted Mode Off On the ninth occurrence the system will stay in restricted mode and await a Logicor engineer or a qualified electrician to check the system for faults. The customer should call either their distributor, Logicor Technical Support of a qualified system engineer for advice.
  • Page 64: Section 3: Status Screen

    Help Mode………………………....(Page 4) Section 2: Control Panel & Temperature Settings (Page 6) Section 3: Status Screen……………......(Page 53) Section 4: Cost & Energy Settings…......(Page 55) Section 5: Timer Settings……………......(Page 58) © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 53...
  • Page 65: Status Screen

    You can choose which status readings are displayed here by pressing the ‘Control Panel & Temperature Settings’ Cog Icon then choosing Main Settings / Screen Options / Status Screen Options (See page 13). © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 54...
  • Page 66: Section 4: Cost & Energy Settings

    Help Mode………………………....(Page 4) Section 2: Control Panel & Temperature Settings (Page 6) Section 3: Status Screen……………......(Page 53) Section 4: Cost & Energy Settings…......(Page 55) Section 5: Timer Settings……………......(Page 58) © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 55...
  • Page 67: Cost & Energy Settings

    Additional systems are proposed for the future that will be listed on this screen if available. Please check our website for product updates. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 56...
  • Page 68: Adjust Cost & Energy Settings

    Press the save button to energy use target with the keypad. store your entry. As you change one reading, all other readings automatically update and adjust to your chosen target. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 57...
  • Page 69: Section 5: Timer Settings

    Help Mode………………………....(Page 4) Section 2: Control Panel & Temperature Settings (Page 6) Section 3: Status Screen……………......(Page 53) Section 4: Cost & Energy Settings…......(Page 55) Section 5: Timer Settings……………......(Page 58) © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 58...
  • Page 70: Timer Settings

    INFO message at the top of the until your room environment cools down by 9°C. At that screen. point the heater system will resume heating to retain the new lower temperature. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 59...
  • Page 71: Weekly Settings

    9°C. At that point the heater system will resume heating to retain the new lower temperature. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 60...
  • Page 72: Add Event

    An event of -9°C for example will in effect switch the heater system off until the room environment cools down by 9°C. At that point heating will resume at the new lower temperature. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 61...
  • Page 73: Adjust Event

    An event of -9°C for example will in effect switch the heater system off until the room environment cools down by 9°C. At that point heating will resume at the new lower temperature. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 62...
  • Page 74: Graphical View

    A reduction in temperature will be shown below the blue line. Your current day and time is displayed below the graph, together with the status of your weekly scheduling; either enabled or disabled. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 63...
  • Page 75: Enable / Disable Scheduling

    INFO message at the top of the until your room environment cools down by 9°C. At that screen. point the heater system will resume heating to retain the new lower temperature. © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 64...
  • Page 76: Specification: Control Panel

    Logicor Model No. Base: Chrome plated Aluminium Electric Supply: Located on the rear of the control panel, connection via CAT5 or CAT6 patch lead to a Logicor 230V ( UK, NZ, Australia ) bespoke power supply unit. The socket outlet shall be...
  • Page 77: Specification: Clear Heater Units

    Note: For placement of heaters in wet room situations we offer an IP53 rated heater which is a special order item. A qualified installer and surveyor will advise if you need this type of unit. © 2016 Logicor (CH) Ltd clear-heater.co.uk...
  • Page 78 Plug. The socket outlet shall be installed near the carton with shock protection. equipment and shall be easily accessible. A Logicor approved installer will be needed to carry out your installation to ensure the heater units are positioned to achieve optimal heating.
  • Page 79: Gh - 518R (Large Heater Unit)

    GH - 518R (Large Heater Unit) © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 68...
  • Page 80: Gh - 518B (Small Heater Unit)

    GH - 518B (Small Heater Unit) © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 69...
  • Page 81: Gh - 518P (Portrait Heater Unit)

    GH - 518P (Portrait Heater Unit) © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 70...
  • Page 82: Gh - 518C (Conservatory Heater Unit)

    GH - 518C (Conservatory Heater Unit) © 2016 Logicor (CH) Ltd clear-heater.co.uk Page 71...
  • Page 83 MANUFACTURER: Logicor (CH) Ltd Unit 7 Thornes Office Park Monckton Road Wakefield WF2 7AN West Yorkshire UK www.logicor.co.uk www.clear-heater.co.uk...

Table of Contents