User Information
·
There are no user serviceable parts, opening or attempting to repair the product will void the
warranty.
·
Do not install or use the device if the wires connected are damaged or have been subjected to
water ingress.
·
Handle the equipment carefully. The holding force can be reduced by damaging the lock body.
·
The strike lock should be fixed tightly in the door frame.
·
Shut off all power to the access control system before wiring this device.
·
Maintain a clean and safe environment at all times.
Definition
NO (Normally Open) - This is a contact which remains open (as default) until activated, during the
"active" state the contact provides a closed circuit and starts conducting.
NC (Normally Closed) - Is the opposite of a NO contact. The contact will remain closed (as default)
until activated, during the "active" state the circuit breaks and stops current flow.
Setup Example
The ACC520 is a Fail Safe strike lock making it ideal for
emergency exits. They work by keeping the door locked
until power is cut when an emergency exit button is
pressed or the building loses power. When the this
happens the doors will unlock allowing staff and visitors
to safely leave the building.
This example shows a the ACC520, when the
button is activated, power supply then releases
power from the lock, and if power is lost then the
lock also releases.
Connect the control device and power to the lock via an
access control panel, relay or exit button so that the
power can be cut when triggered.
For a Fail Secure setup the ACC518 strike lock works the
opposite way to most electronic locks as they are
designed to lock the door when their power is cut.
The lock can also be connected to a HRM250 - 10
function relay. A custom set length of time can be
set for how long the power is cut from the lock.
Document ref: qACC518-520
Strike Locks
Strike locks are designed to replace the original latch plate in a
door frame.
The ACC520 is Fail Safe lock which unlocks when power lost
ideal for emergency exits.
The ACC518 is a Fail Secure lock on power loss perfect for
security doors.
ZapCCTV.com
Strike Locks
Zap is a registered trademark of System Q Ltd
© 2022 System Q Ltd
1

Advertisement

loading

Summary of Contents for Zap ACC518

  • Page 1 Strike locks are designed to replace the original latch plate in a door frame. The ACC520 is Fail Safe lock which unlocks when power lost ideal for emergency exits. The ACC518 is a Fail Secure lock on power loss perfect for security doors. User Information ·...
  • Page 2 Strike Locks Zap is a registered trademark of System Q Ltd This allows for installations where the exit button isn't situated next to the door and a timed released is required. Mounting Cut the hole for the electric bolt in the door frame.

This manual is also suitable for:

Acc520