 Check the switch (No 08) which indicates the buck's heating on the panel.
 Check the heating element of the ironing buck.
8.3 The heating of the working surface is not activated
 Check if the fuse 12Α inside the fuse case No 07 is burnt out. Replace it.
 Check if the thermostat No 10 is faulty. Replace it.
 Check if the safety thermostat No 11 is faulty. Replace it.
 Check if the heating element No 09 is burnt out. Replace it.

8.4 The machine operates loudly

 Check if the ball bearings of the motor are faulty. Replace them.
 Check the impeller to be sure, that there is no dust which could cause the vibration.

8.5 The blowing of air does not function

(If you have purchased the Eco DOB S+B)
 Check if the blowing's bouton pedal No 44 is damaged.
 Check the motor No 45.