Gateway 450RGH Datasheet
Gateway 450RGH Datasheet

Gateway 450RGH Datasheet

Gateway 450rgh: software guide
Hide thumbs Also See for 450RGH:
Table of Contents

Advertisement

Protector Suite QL
Datasheet
Protector Suite QL
Datasheet
Rev: <1.0.2>
March 30, 2004
1/15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 450RGH and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gateway 450RGH

  • Page 1 Protector Suite QL Datasheet Protector Suite QL Datasheet Rev: <1.0.2> March 30, 2004 1/15...
  • Page 2: Table Of Contents

    PS QL Datasheet Table of Contents Introduction... 4 PS QL End Users ... 4 User interface... 4 One Touch behavior... 5 Behavior in case of logged-off or locked computer... 5 Behavior in case of logged-on computer ... 5 Features... 6 Feature description...
  • Page 3 6.35 Ultra low power finger detect mode (Win XP)...12 TouchChip Bios eXtension (TBX) support in Protector Suite QL... 13 Introduction ...13 Turning on TBX ...13 User enrollment ...13 Single sign on feature: one touch or swipe to access PC and log on to Windows ..14 PS QL Datasheet 3/15...
  • Page 4: Introduction

    PS QL Datasheet Main Features One Touch access User Logon Fast User switching Protector Suite QL touch menu Encrypted Data storage Easy access to secure storage Security on shared PC environment Password Management Easy registration of password dialogs Multi browser support Exportable Password bank Pre-Boot support For TBX enabled Notebooks and Desktops pre-boot protection...
  • Page 5: One Touch Behavior

    Figure 1: Bio menu in Aluminium and TouchChip skins To increase the acceptance by individuals this main menu can have a choice of multiple “skins”. One of the skins is plain Windows XP standard-looking. The skins apply only to the main menu;...
  • Page 6: Features

    PS QL Datasheet 5 Features Feature description General Features: Supported operating systems : Windows XP with or without FUS (Fast User Switching) Windows 2000 Windows Me/98 Automatic hints, which will help user to understand the product and solve problems Tutorial teaching user how to use strip sensor Automatic user enrollment after new user logon One touch/swipe function to activate User Interface User interface optionally controlled by movement of user’s finger...
  • Page 7 Security features: User’s data encryption File folder “My Safe” in “My documents” folder will be encrypted. Access to “My Safe” can be locked/unlocked by a finger (from menu) My Safe can be resized My Safe can be unlocked from standard Open/Save file dialogs Fingerprint Reader support Automatic installation of HW drivers during setup...
  • Page 8: Feature Description

    PS QL Datasheet 6 Feature description Targeted for Windows OS The PS QL will work with the following OS: Windows XP Windows 2000 Windows Me and 98. The most suitable environment is Windows XP with Fast User Switching feature turned on, where users can benefit from the Fast User Switching features of PS QL.
  • Page 9: One Touch Function To Activate User Interface

    Figure 3: Protector Suite QL Welcome screen One touch function to activate User Interface If the user is logged on to the computer, user just has to place/swipe his finger on the sensor to invoke the main Protector Suite QL menu. User interface optionally controlled by movement of user’s finger on the sensor The user interface can be controlled by a mouse or by movement of user’s finger on the...
  • Page 10: Silent Setup

    PS QL Datasheet 6.10 Silent setup A silent setup mode is supported. This allows remote or unattended installation, e.g. using Microsoft SMS server. 6.11 Microsoft Installer support The setup uses the Microsoft Installer technology and therefore supports all Microsoft Installer features. 6.12 Configurable s kins To increase the future coolness factor it is possible to change the look of the main user interface.
  • Page 11: Possibility To Edit Registrations

    PS QL Datasheet 6.22 Possibility to edit registrations User can edit the registration data (like the username or password) for each registration. The user can change parts of the registration without the need to re-register the window. 6.23 Possibility to see the password, which is stored in the registration The passwords stored in the registration are not shown by default but the user can make them visible during editing.
  • Page 12: File Folder "My Safe" In "My Documents" Folder Will Be Encrypted

    PS QL Datasheet 6.28 File folder “My Safe” in “My documents” folder will be encrypted Everything stored in this special folder is on-line encrypted. User does not need to care about choosing files to encrypt – just store the file in this folder. The user also does not need to remember to re-encrypt the file after usage.
  • Page 13: Touchchip Bios Extension (Tbx) Support In Protector Suite Ql

    7 TouchChip Bios eXtension (TBX) support in Protector Suite QL Introduction TBX technology allows to protect computer from boot and subsequent usage by an unauthorized user. TBX BIOS level protection by fingerprint authentication is optional – it can be enabled or disabled using manually by changing a setting in PS QL, or it can be turned on automatically by PS QL (see below).
  • Page 14: Single Sign On Feature: One Touch Or Swipe To Access Pc And Log On To Windows

    PS QL Datasheet PS QL software represents the only means to enroll and administer fingerprints for fingerprint BIOS level protection (TBX). When a user edits his enrolled fingers (adds or deletes templates) in PS QL, the change is automatically uploaded also to the TBX memory.
  • Page 15 PS QL Datasheet Information furnished is believed to be accurate and reliable. However, Upek, Inc assumes no responsibility for the consequences of use of such information not for any infringement of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Upek, Inc.

Table of Contents