All manuals and user guides at all-guides.com Dear customer, please read the instruction book and all additional information before using the appliance. It is most important that they should be retained with the appliance for future reference! 1. Warnings and directions These warnings are provided in the interest of safety.
All manuals and user guides at all-guides.com 3. Storage of gas cylinders Liquid gas cylinders should never be stored in unventilated areas or below ground (funnel-shaped holes). Avoid direct sunlight. The gas cylinder should not be exposed to temperatures in excess of 50°C. 4.
Page 5
All manuals and user guides at all-guides.com Turn thermostat knob (A) anticlockwise to position '0'=off (a slight resistance will be felt just before this position). Pull out mains plug. 7. D/C operation Do not use any additional form of energy (mains/gas). A safety fuse must be installed in the electricity supply between battery and refrigerator in a duct.
All manuals and user guides at all-guides.com The refrigerator is equipped for a specific gas-pressure, corresponding to the standard pressure of the country in which it is sold. The rating-plate states the pressure which is correct. It is important that a non adjustable pressure-regulator is used to reduce the pressure in the gas cylinder to the operating pressure specified on the rating-plate, no other pressure may be used.
Page 7
All manuals and user guides at all-guides.com 4. After approximately 10 seconds press knob (E) several times. (This could take longer than 10 seconds if the unit has been out of operation for a prolonged period or after replacing the gas cylinder. Cause: air in the pipes.) After ignition, hold down knob (B) for a further 20-30 seconds before releasing.
All manuals and user guides at all-guides.com To avoid any unpleasant smells forming in the cooler, the lid should be left slightly open. 15. Measures after prolonged periods of disuse Should the refrigerator not function correctly after being switched on, place the unit upside down WITHOUT ANY CONNECTING POWER SUPPLY.
All manuals and user guides at all-guides.com 18. After-sales service Should a problem arise with the unit, please check the following before contacting customer service: is the unit suitably placed and is it well ventilated? is the unit placed on a flat surface? does the socket supply current? is the connecting cable damaged in any way? is there a loose connection?
All manuals and user guides at all-guides.com 19. Technical Data Gas operation: butane (propane) Rated thermal loading: 188 W (192W) Min. thermal loading: 95 W (98W) Connected load, gas: 13,6 g/h (13,7 g/h) Connection pressure: 28-30/37 mbar Categorie: Climat class: N...
Page 11
All manuals and user guides at all-guides.com Joint Fig 2 Joints Fig 3...
Page 12