Safety Precaution For Service Manual; Important Service Notes (For U.k. Only) - Sharp CD-PC671H Service Manual

Table of Contents

Advertisement

CD-PC671H/PC651H
SAFETY PRECAUTION FOR
SERVICE MANUAL
Precaution to be taken when replacing and servicing the
Laser Pickup.
The AEL (Accessible Emission Level) of Laser Power Output
for this model is specified to be lower than Class I Requirements.
However, the following precautions must be observed during
servicing to protect your eyes against exposure to the Laser
beam.
(1) When the cabinet has been removed, the power is turned
on without a compact disc, and the Pickup is on a position
outer than the lead-in position, the Laser will light for several
seconds to detect a disc. Do not look into the Pickup Lens.
(2) The Laser Power Output of the Pickup inside the unit and
replacement service parts have already been adjusted prior
to shipping.
(3) No adjustment to the Laser Power should be attempted
when replacing or servicing the Pickup.
(4) Under no circumstances look directly into the Pickup Lens
at any time.
(5) CAUTION - Use of controls or adjustments, or performance
of procedures other than those specified herein may result
in hazardous radiation exposure.
(Except for U.K.)
LASER KLASSE 1
LUOKAN 1 LASERLAITE
KLASS 1 LASERAPPARAT

IMPORTANT SERVICE NOTES (FOR U.K. ONLY)

Before returning the unit to the customer after completion of a
repair or adjustment it is necessary for the following withstand
voltage test to be applied to ensure the unit is safe for the
customer to use.
Setting of Withstanding Voltage Tester and set.
Set name
Withstanding Voltage Tester
Test voltage
Set time
Set current(Cutoff current)
Unit
Judgment
OK: The "GOOD" lamp lights.
NG: The "NG" lamp lights and the buzzor sounds.
set value
4,240 VPEAK
3,000 VRMS
6 secs
4 mA
Laser Diode Properties
Material: GaAIAs
Wavelength: 780 nm
Emission Duration: continuous
Laser Output: max. 0.6 mW
CAUTION-INVISIBLE LASER RADIATION WHEN OPEN. DO NOT STARE INTO
BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS.
VARNING-OSYNLIG LASERSTRALNING NAR DENNA DEL AR OPPNAD. STIRRA
EJ IN I STRALEN OCH BETRAKTA EJ STRALEN MED OPTISKA INSTRUMENT.
ADVERSEL-USYNLIG LASERSTRALING VED ABNING. SE IKKE IND I
STRALEN-HELLER IKKE MED OPTISKE INSTRUMENTER.
VARO! AVATTAESSA OLET ALTTIINA NAKYMATON LASERSATEILYLLE.
ALA TUIJOTA SATEESEEN ALAKA KATSO SITA OPTISEN LAITTEEN LAPI.
VARNING-OSYNLIG LASERSTRALNING NAR DENNA DEL AR OPPNAD.
STIRRA EJ IN I STRALEN OCH BETRAKTA EJ STRALEN GENOM OPTISKT
INSTRUMENT.
ADVERSEL-USYNLIG LASERSTRALING NAR DEKSEL APNES. STIRR IKKE
INN I STRALEN ELLER SE DIREKTE MED OPTISKE INSTRUMENTER.
VAROITUS! LAITTEEN KéYT Té MINEN MUULLA KUIN
TéSSé
KéYTTô OHJEESSA MAINITULLA TAVALLA SAATTAA
ALTISTAA KéY TTéJ éN T URVALLISUUSLUOKAN 1
YLITTéVéLLE NéKYMéTTôMéLLE LASERSéTEILYLLE.
VARNING - OM APPARATEN ANVéNDS Pè ANNAT SéTT
éN I DENNA BRUKSANVISNING SPECIFICERAS. KAN
A NV é N DA RE N
UT S é T T AS
LASERSTRèLNING, SOM ôVERSKRIDER GRéNSEN FôR
LASERKLASS 1.
WITHSTANDING
VOLTAGE TESTER
AC
– 2 –
(For U.K.)
Fô R
OSY NLI G
PROBE
+
OUT
-
UNIT
CONNECT THE PROBE
SHORT-CIRCUIT
TO GND
OF CHASSIS
AC POWER
SCREW
SUPPLY CORD