Download Print this page
Synetica enLink Zone Quick Start Manual

Synetica enLink Zone Quick Start Manual

Wireless environmental sensor

Advertisement

Quick Links

Quick Start Guide
enLink Zone
Wireless environmental sensor
LoRa long range wireless
Battery powered
Built in sensors for:
Temperature (°C)
Carbon Dioxide (CO
Barometric Pressure (Pa)*
Volatile Organic Compounds (VOC's)*
Temperature
Humidity
enLink Zone accurately measures multiple environmental
parameters including room temperature, humidity, light level,
VOC's, CO
, barometric pressure and human presence (motion)*.
2
Volatile Organic Compounds (VOC's) from paints (such as
formaldehyde), lacquers, paint strippers, cleaning supplies,
furnishings, office equipment, glues, adhesives and alcohol can be
detected.
Readings are transmitted to the cloud using long range LoRa
wireless, where the data can be displayed and analysed.
The unit is battery powered with long life of 3+ years
A built in USB port allows all parameters including sensor, air
quality data, wireless signal strength and wireless network
configuration to be viewed and set using simple menus via any
USB enabled host such as a PC or Mac.
)*
2
Light level
VOC's
#
.
Humidity (%RH)
Motion (PIR)*
Light level (lux)*
CO
Pressure
2
Features
• Multiple sensor options*
• LoRa long range wireless
• Frequency Range 863-870MHz*
• Frequency Range 902-928MHz*
• Up to +16dBm Tx Power
• Built in USB port for power and
configuration
• Battery or mains powered
• CE compliant
• RoHS compliant
• Made in the UK
*Model dependent, see Selection Guide section
#
Dependent on factors such as transmission interval
Motion

Advertisement

loading
Need help?

Need help?

Do you have a question about the enLink Zone and is the answer not in the manual?

Questions and answers

Summary of Contents for Synetica enLink Zone

  • Page 1 Temperature Humidity Light level VOC’s Pressure Motion enLink Zone accurately measures multiple environmental Features parameters including room temperature, humidity, light level, VOC’s, CO , barometric pressure and human presence (motion)*. • Multiple sensor options* Volatile Organic Compounds (VOC’s) from paints (such as •...
  • Page 2 Note: In LoRaWAN 1.1, AppEUI was renamed to JoinEUI. For many applications Synetica can supply enLink Zone units with the AppEUI and AppKey pre-configured, so providing the LoRa gateway has the matching values, the join process will happen automatically once the Zone unit is in wireless range and switched The DevEUI is always set at device manufacture and is unique.
  • Page 3: Battery Installation/Replacement

    Only install approved batteries: SAFT LS14500 Lithium Thionyl Chloride AA Battery 3.6 Volt, or direct equivalent. Safe disposal • Please recycle responsibly, a wide range of schemes are available. • Do not dispose of in normal waste or in a fire. SYNETICA enLink Zone Quick Start Guide Rev 1.4...
  • Page 4 To get started with enLink Zone wireless sensor, follow these steps: 1. Setup using Multitech Conduit® AEP MultiTech’s Conduit is a leading configurable, manageable, and scalable LoRa gateway and can be quickly and easily configured to create a LoRaWAN network with enLink LoRa devices.
  • Page 5 This screen shows details of devices which have joined the network, when they joined and when the last message was received from them. As you add devices to the network, this is where they will appear. SYNETICA enLink Zone Quick Start Guide Rev 1.4...
  • Page 6 SYNETICA enLink Zone Quick Start Guide Rev 1.4...
  • Page 7 The unique DevEUI is printed on all enLink devices and is also present in the QR code. The DevEUI can be used to identify the device once joined to the network. To power the device ON, remove the rear cover of the enLink Zone by inserting a small screwdriver blade into the slots on the bottom of the unit as shown below.
  • Page 8 The LED’s will then switch off to conserve the batteries. Blinking Green LED – Device Successfully Joined Devices which have Joined the network appear in the Conduit LoRaWAN - > Devices menu as shown previously. SYNETICA enLink Zone Quick Start Guide Rev 1.4...
  • Page 9 Remove the enLink Zone board from its enclosure as shown previously. Take care when removing the board from the front part of the enclosure and only use the slots provided at the bottom of the board to gently lift the board up and out of the enclosure.
  • Page 10 Enter R to reboot followed by OK. The device will restart with the entered AppEUI and AppKey and attempt to join the LoRa network. Reboot Required notification Check the Conduit LoRaWAN -> Devices menu detailed previously to verify that the enLink device has joined successfully. SYNETICA enLink Zone Quick Start Guide Rev 1.4...
  • Page 11: Configuration Menu

    Live status screen, from the Main Menu enter c for Configure Device followed by d for Live readings display. A screen similar to the one below will show. The sensors will vary according to the enLink Zone model and the installed sensors.
  • Page 12: Technical Support

    451ppm in the interval. Technical Support For technical assistance, please visit the downloads section of our web site at www.synetica.net or email us at support@synetica.net SYNETICA enLink Zone Quick Start Guide Rev 1.4...