described previously, attach the mounting bracket to the electrical box. To ensure aesthetic alignment of the alarm
with the hallway, or wall, the "A" line on the mounting bracket should be parallel with the hallway when ceiling
mounted, or horizontal when wall mounted.
• Pull the AC QUICK CONNECTOR through the center hole in the mounting bracket and secure the bracket, making
sure that the mounting screws are positioned in the small ends of the keyholes before tightening the screws.
• Plug the AC QUICK CONNECTOR into the wiring harness attached to the unit, making sure that the locks on the
connector snap into place. Then push the excess wire back into the electrical box through the hole in the center of
the mounting bracket.Install the alarm fully on the mounting bracket by rotating the alarm in a clockwise direction.
NOTE: Installing the alarm on the mounting bracket will automatically activate the battery backup. A voice "Push
Test Button" will occur when power is first activated.
• Turn on the AC power. The green AC Power On Indicator should be lit when the alarm is operating from AC power.
NOTE: Attaching AC power first, without rotating the alarm onto the mounting bracket, will result in a false low
battery trouble condition chirp and voice notification (see Troubleshooting guide). You need to activate the battery
to eliminate the false low battery trouble condition chirps and voice. Attach unit to mounting bracket very soon
after applying AC power to avoid false low battery notification.
NOTE: The battery activation is a one-time feature that occurs when the alarm is rotated fully onto the mounting
bracket. After activation, the battery cannot be turned off, and can only be discharged at the end of unit life. If the
alarm is removed from the mounting bracket, the backup battery will remain active. See Permanently Disable Alarm
/ Discharge Battery section.
AC Wired Interconnect Model Capability
This model has AC hardwire interconnect capability. When one hardwired interconnect unit sounds an alarm, all other
compatible hardwired interconnected units will also alarm.
• The following models can be interconnected using the standard AC wiring interconnect: 1235, 1275, 1276, 1285,
i12020, i12020A, i12040, i12040A, i12060, i12060A, i12080, i12080A, i4618, i4618A, i4618AC, KN-SMFM-I,
RF-SM-ACDC, PE120, P12040, Pi2000, Pi2010, KN-COSM-I, KN-COSM-IB, KN-COSM-IBA, KN-COPE-I,
KN-COPE-IC, KN-COB-IC, KN-COP-IC, SL177i, SLED177i, HD135F, SM120X, CO120X, i12010S, i12010SCO,
P4010ACSCO, P4010ACSCO-W, P4010LACS-W, P4010ACS, P4010ACS-W, 3050-VAS10, 3050-VASC10, 2070-VASCR, 2070-
VASR.
The alarm is now activated! After installation / activation, test your alarm as described in Operation and Testing section.
WARNING: fAILURE TO pROpERLy INSTALL AND ACTIVATE THIS ALARM WILL pREVENT pROpER OpERA-
TION Of THIS ALARM AND WILL pREVENT ITS RESpONSE TO fIRE HAzARDS.