Bedpan cleaning and
disinfection unit
With controller,
operating manual and
technical information
Mit Steuerung
Bedienungsanleitung und
Technische Hinweise
Last updated: 18/05/2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the euroMAT light Bedpan and is the answer not in the manual?

Questions and answers

Summary of Contents for bg edelstahl euroMAT light Bedpan

  • Page 1 Bedpan cleaning and disinfection unit With controller, operating manual and technical information Mit Steuerung Bedienungsanleitung und Technische Hinweise Last updated: 18/05/2020...
  • Page 2: Table Of Contents

    The contents of this publication may not be reproduced or copied in whole or in part without the prior consent of bg edelstahl und kunststofftechnik für krankenhaus, industrie und wasserwirt- schaft gmbh.
  • Page 3: Introduction

    1. Introduction 3.1 Overview of functions / intended purpose 1. Einleitung The euroMAT basic bedpan cleaning unit is used for cleaning and disin- This operating and maintenance manual is intended to ensure that the 3.1 Funktionsübersicht Diese Bedienungs- und Wartungsanleitung soll den korrekten Gebrauch fecting urine bottles, bedpans and commode buckets.
  • Page 4: Control Elements

    4. Control elements Kurzprogramm mablauf Normalprogramm Control panel Status messages, error messages and maintenance intervals via diode display. Randspülung oder WC-Spülung Intensivprogramm Start Rinsing programs for cleaning bedpans, urine bottles, commode buckets, kidney dishes, etc. enfeld 4.2 Beladen ahren sie detailliert die durchzuführenden Schritte, um 4.3 Loading 4.1 Operation igungs- und Desinfektionsergebnis zu erhalten.
  • Page 5: Description Of The Programs

    4.4 Description of the programs Dish drainage stage The door is locked throughout the entire cleaning process and cannot be opened until cleaning, disinfection and cooling are all complete. The selected program is indicated by an LED in the relevant keyboard icon.
  • Page 6 No cold water supply Error – deadbolt Cause: Valve or activation (also for ‘Error – door lock’) Cause: defective; cable defective; water The door cannot be locked; the tap turned off Remedy: Check magnet or tappet is blocked the water tap. Check the valve / Remedy: Close the door cor- cable (Service).
  • Page 7: Program End And Unloading

    Water inlet valve defective 4.6.1 Mechanical unlocking during a power failure (also for ‘Close the door imme- Open the top revision panel. Pull the tappet upwards slightly using diately’) Cause: The tank is filled pliers (figure). higher than the setpoint (inlet valve or activation defective) Remedy: Turn off the water tap;...
  • Page 8: Warehousing / Storing A Bedpan Cleaning Unit

    Please proceed as follows to obtain the unit information panel is 85°C – 87°C, the value on the external measuring device listed below: must be noted simultaneously (within one second), otherwise the result is falsified. 1. Open the rinsing chamber door Wait for the rinse cycle to end.
  • Page 9: Maintenance Schedule

    6.2 Maintenance schedule The following parts must be inspected, cleaned and (if necessary) replaced during annual maintenance. Abbreviations: I = Inspect C = Clean R = Replace V = Verification CA = Calibration Year of operation Part CW supply hoses HW supply hoses Existing dirt strainers Solenoid valves...
  • Page 10: Proof Of Maintenance

    6.3 Proof of maintenance The following tasks were carried out during maintenance work. Abbreviations: I = Inspect C = Clean R = Replace V = Verification CA = Calibration Year of operation Part CW supply hoses HW supply hoses Existing dirt strainers Solenoid valves Rinsing chamber / pipe Rinsing impeller...
  • Page 11: Uninstalling / Disposal

    6.4 Uninstalling / disposal be used, otherwise safety and hygienic success cannot be guaranteed. Please proceed as follows to uninstall the bedpan cleaning unit: Technical data • Unplug the mains plug. euroMAT basic is monitored – compliant – inspected in accordance with: •...
  • Page 12: Medical Devices Book

    8. Medical devices book 8.1 Unit master data Nature and type Serial number Heating number Year of acquisition Initial commissioning (MM/YYYY) Manufacturer Supplier Company ID number Location and operational assignment Deadlines for safety checks (see sticker on the product) Last updated: 18/05/2020...
  • Page 13: Functional Test And Briefing

    8.2 Functional test and briefing Inventory no. Functional test Briefings Person responsible: Name of the person respon- Time Manufacturer / supplier Signature sible for the briefing Last updated: 18/05/2020...
  • Page 14: Briefing Staff

    8.3 Briefing staff Person providing the Time Name of the person briefed Signature briefing Last updated: 18/05/2020...
  • Page 15: Malfunctions Or Repeated Similar

    8.4 Malfunctions or repeated similar operating errors Inventory no. Time Description of nature and consequences Last updated: 18/05/2020...
  • Page 16 8.5 Malfunctions or repeated similar operating errors Inventory no. Time Description of the reported incident Last updated: 18/05/2020...
  • Page 17 Installation and commissioning log IMPORTANT! Please fill out this log carefully and RETURN IT to the manufacturer or to the relevant sales partner! Postal address: Name of the company: Contact: Street / no.: Postcode / Town/city: Serial number: Unit location: Unit type / designation: Installation: Unit installed Housing...
  • Page 18: Personal Notes

    9. Personal notes Last updated: 18/05/2020...
  • Page 19 9. Personal notes Last updated: 18/05/2020...
  • Page 20: Important Addresses

    Phone: Phone: Fax: Technical Service: Notify: Name: Name: bg edelstahl und kunststofftechnik für krankenhaus, Phone: industrie und wasserwirtschaft gmbh Phone: +49 (0) 23 68 - 699 36 - 0 Emergency call: Fax: +49 (0) 23 68 - 699 36 - 33 Name: bg edelstahl und kunststofftechnik für krankenhaus,...

Table of Contents