Lake Shore Cryotronics Measure Ready M81 Quick Start Manual

Lake Shore Cryotronics Measure Ready M81 Quick Start Manual

Synchronous source measure system

Advertisement

Quick Links

Quick Start Guide
M81 Synchronous Source Measure System
1
MeasureReady™ M81 Synchronous Source Measure System Quick Start Guide
https://www.lakeshore.com/M81/

Advertisement

Table of Contents
loading

Summary of Contents for Lake Shore Cryotronics Measure Ready M81

  • Page 1 Quick Start Guide ™ M81 Synchronous Source Measure System MeasureReady™ M81 Synchronous Source Measure System Quick Start Guide https://www.lakeshore.com/M81/...
  • Page 2: Safety Precautions

    3-contact electrical outlet or use a 3-contact intended instrument use. Lake Shore Cryotronics, Inc. assumes no adapter with the grounding wire (green) firmly connected to an liability for Customer failure to comply with these requirements.
  • Page 3: Key Specifications

    Return the instrument to an to 40 °C at reduced accuracy authorized Lake Shore Cryotronics, Inc. representative for service and repair to ensure that safety features are maintained. If the equipment is used in a manner not specified by the manufacturer, Power requirement the protection provided by the equipment may be impaired.
  • Page 4 MeasureReady™ M81 Synchronous Source Measure System Quick Start Guide Introduction Features Unique real-time sampling architecture for synchronous „ This guide provides basic information for getting started sourcing and measuring with your MeasureReady™ M81 synchronous source „ MeasureSync™ technology for simultaneous measure system (SSM™).
  • Page 5 Components of the M81-SSM „ The absolute accuracy of DC plus the detection Connect up to three source modules and up to three „ sensitivity of lock-in instrumentation measure modules „ All source and measure channels are capable of Exchange modules and adapt the configuration for „...
  • Page 6: Front Panel

    MeasureReady™ M81 Synchronous Source Measure System Quick Start Guide Front panel Rear panel The rear panel consists of: The front panel consists of: LEMO source module connectors Power button 2. LEMO measure module connectors 3. BNC reference input 2. TiltView™ touchscreen 4.
  • Page 7 Startup Module connection Instrument connection Connect the measurement module(s) to the rear „ Plug in the MeasureReady™ M81-SSM using the „ panel of the M81-SSM. supplied power cord. The instrument will begin its power-up sequence. After the sequence is complete (this may take approximately 45 s during initial operation), the Home screen is displayed.
  • Page 8 MeasureReady™ M81 Synchronous Source Measure System Quick Start Guide Basic source operation Enable/Disable A source module’s output can be enabled or disabled To configure a source module on the front panel, with the slider switch. When the switch is red, the output navigate to the tab for the module.
  • Page 9 Basic measurement operation Display To configure a measurement module on the front panel, navigate to the tab for the module. In DC mode, the display will show a single value, which is NOTE: Additional measurement module settings will also the DC indication. be displayed.
  • Page 10 MeasureReady™ M81 Synchronous Source Measure System Quick Start Guide Lock-in mode Display In AC mode, the display can be configured to show In lock-in mode, the MeasureReady™ M81-SSM will detect either Total RMS and DC indications, or Peak to Peak signals which are coherent with the configured reference and +Peak, -Peak indications.
  • Page 11 Display Reference source In lock-in mode, the display can be configured to show The measure channel will detect frequencies which either rectangular coordinates (X, Y) or polar coordinates are coherent with the specified reference source. For (R, θ). In addition, the % of Range and Frequency are example, if a sample is being excited with a current by S1, always displayed.
  • Page 12: Remote Operation

    MeasureReady™ M81 Synchronous Source Measure System Quick Start Guide Remote operation Time constant If desired, attach the the MeasureReady™ M81-SSM to your PC using Ethernet, USB-Type B, or GPIB. The time constant setting determines the bandwidth of the PSD output filter. Longer time constants will result in USB-Type B: implemented as a virtual serial „...
  • Page 13 Remote access Ethernet: provides a means of connecting the „ The M81 adheres to the Standard Commands for M81 to an Ethernet based computer network. Programmable Instruments (SCPI) standard. Once The Ethernet interface provides the following connected to your PC, the M81 can be remotely operated capabilities: in the following ways: „...
  • Page 14 MeasureReady™ M81 Synchronous Source Measure System Quick Start Guide MeasureLINK™-MCS software Computer interface connections A license for MeasureLINK™-MCS software is included The USB connection will be listed as a virtual COM port with the MeasureReady™ M81-SSM™. The software can be on your PC.
  • Page 15: Contacting Lake Shore

    The Lake Shore Forum is also a great place to look for solutions, to post issues, and to share successes: http://forums.lakeshore.com/. For further documentation and information, please see https://www.lakeshore.com/M81/. Lake Shore Service Lake Shore Cryotronics Instrument Service Department 575 McCorkle Blvd. Westerville, Ohio USA 43082-8888...
  • Page 16 MeasureReady™ M81 Synchronous Source Measure System Quick Start Guide Rev. 1.1 P/N 119-M81-Q 1 July 2021...