INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS FOR
RANGE HOODS DESIGNED FOR WALL FITTING 230 Vac • 50 Hz
Exhausting cooker hood
The equipment is constructed in accordance with
European Standards and the requirements included in
the following Directives: 73/23 EEC (electric-low tension
safety), 89/336 EEC (electromagnetic compatibility),
93/68 EEC (EC marking regulations).
Before installing and/or using the hood:
• read all the instructions thoroughly;
• be sure that the ceiling structure is suitable for the
installation of this heavy equipment
• make sure that the voltage (V) and frequency (Hz)
ratings indicated on the plate inside the hood unit
correspond to the ones available in the installation
place.
• At least two people are needed for the installation
procedure, which it is advisable to entrust to competent
technicians.
USE
This cooker hood can be employed as exhausting
or filtering. Exhausting (external evacuation). Kitchen
smokes are driven outside through a flue (not provided
with the hood) joined to the exhaust pipe flue connector.
This pipe must not under any circumstances be
connected to cooker, boiler or burner exhaust pipes,
etc.
The use of pipes and holes on the wall with a smaller
diameter than the output of the motor will cause a
decrease in suction performance and an increased of
the noise level.
Use as short as possible tubes and with few curves.
Use pipes with smooth internal surfaces.
Filtering (inside recycling). The fumes pass through
activated carbon filters (supplied with the hood) to be
purified and recycled into the kitchen.
1. INSTALLATION
Read the instruction manual before installing and/or
using the hood. The minimum distance between the
supporting surface of the cooking hob and the lowest
part of the range hood must be not less than 65cm with
a gas hob. If the mounting instructions of the gas hob
indicate a wider distance, respect it.
The unit must not be mounted above cookers fitted
with top radiant plate.
For proper operation, it is recommended to install the
product at a distance of 200 – 210 cm from the floor.
Respect all the air discharge regulations.
The air must not be discharged in a pipe used to
discharge exhaust fumes produced by gas-fed
equipments or fuel-fed equipments (this does not apply
to filtering hoods).
The room must be adequately ventilated when
the hoods is used together with other gas or fuel
equipments.
For an easy access, it is advisable to move possible
furniture under the installation area.
Installation of the hood
The hood is equipped with all the necessary fastenings
for its installation, which are suitable for most surfaces.
Verify that the installation surface is strong.
Installation must be carried out by qualified installers
according to present regulations.
EXHAUSTING:
The hood can be installed in two different ways:
Fixed with the motor directly on the ceiling (possible
only when the distance between the ceiling and the
false ceiling is between 210 and 270mm). Follow the
visual instructions Fig. 1-2-3-4-5-6.
Fixed with the motor directly on the false ceiling.
Follow the visual instructions Fig. 7-8.
FILTERING:
Assemble the box combining the four inox walls and
fixing them manually folding the inox tabs. Fig. 9
Fix the box to the hood with the provided screws. Fig. 10
Adjust the height of the two mounting brackets at
162mm. Fig. 11 Install the hood to the ceiling following
the visual instructions Fig. 12-13- 14-15
The motor can also be positioned away from the hood
at a distance not longer than 7m. In this case the hood
can only be used in the exhausting version. If the motor
is installed on the wall it is prohibited to have the air outlet
on the side. Fig. 16
For the electrical connection of the motor away from the
hood always use the supplied extension cord and make
the earthing connection using the yellow-green wire.

2. ELECTRICAL CONNECTIONS

This equipment must be connected to a grounding plant.
Two types of electrical connection can be used:
1. Using a standard plug to be connected to the power
cable and inserted in a mains socket which must be
accessible (so that the plug can be disconnected when
servicing is carried out). Make sure that the plug is
accessible also after the complete installation of the
equipment.
2. By means of a fixed mains connection, fitting a
bipolar switch, which ensures the disconnection, with an
opening distance of the contacts allowing a complete
disconnection on the conditions of the over voltage
III category, according to installation regulations. The
ground connection (yellow-green wire) must not be
interrupted.
Refer to the plate inside the hood for the mains voltage
and frequency ratings.
If the power cable is damaged, it must be replaced by
the manufacturer or by its service agent or a qualified
person in order to avoid any risk.
For stationary appliances permanently connected to
the fixed wiring, compliance with this requirement is
considered to be met if the instruction concerning
1 1