sisel Enda ATDW02 Quick Start Manual page 2

Rail mounted dishwasher time relay

Advertisement

ENDA
ATDW02 -2R-UV
DISHWASHER TIMER
T5
T5
R R
T0
T0
T0
T0 T1
T1 W W
T1
T1
T5
T5
T4
T4
T2
T2
T3
T3
T2
T2 T3
T3 T4
T4
POWER
U1
U1
U2
U2
230V AC
+10% -20%
50/60Hz
Max. 10VA
U1
U2
8
6 8 0 4 0 7
DIMENSIONS
Side View
SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.
Şerifali Mah.
Barbaros Cad. No:18
Y.Dudullu 34775
ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx.
Fax : +90 216 365 74 01
url : www.enda.com.tr
Rinsing
Motor
R
W
Washing
Motor
L1
L2
L3
N
Made in Turkey
7 0 3 0 8 1
SN: XXXXXXXXX
Top View
Bottom View
18,5 mm
62 mm
R R
T5
T0
25
30
20
15
66 mm
10
5
1
RINSE
TIME(s)
ENDA
ATDW02
DISHWASHER
TIMER
T2
T2
U1
U2
CONNECTION DIAGRAM
Rinsing time selection.
R R
T5
Washing motor indicator.
Rinsing motor indicator.
T0
T0
T0
T1
T1
25
30
T2
T2
20
15
T3
T3
10
5
1
RINSE
TIME(s)
Rinsing Motor
R
ENDA
ATDW02
W
DISHWASHER
TIMER
Fuse should
Washing Motor
be connected
T2
T2
100 mA
250V AC
U2
U1
2 / 2
ENDA ATDW02 Series timers are rail mounted devices. Make
sure that the device is used only for intended purpose. The
shielding must be grounded on the instrument side. During an
installation, all of the cables that are connected to the device
must be free of energy. The device must be protected against
inadmissible humidity, vibrations, severe soiling and make sure that the
T5
T5
operation temperature is not exceeded. All input and output lines that are not
connected to the supply network must be laid out as shielded and twisted
T4
T4
cables. These cables should not be close to the power cables or components.
The installation and electrical connections must be carried on by a qualified
staff and must be according to the relevant locally applicable regulations.
L1
L2
L3
N
MOUNTING / REMOVING
2
2
To removing the device from rail ;
1
- Push the rails lock in direction
1
screwdriver and pull the device in direction
Note :
1) Mains supply cords shall meet the
requirements of IEC 60227 or IEC 60245.
2) In accordance with the safety regulations,
the power supply switch shall bring the
identification of the relevant instrument and it
should be easily accessible by the operator.
Holding screw
0.4Nm
1
1
To mounting the device on rail ;
- Push the device to rail in direction
and make sure that the rail lock
1
is interlocked to rail.
1
with a
2
ENDA
TM
ATDW02-EN-190220