Ammann ARW 65 Operating Instructions Manual page 59

Table of Contents

Advertisement

Available languages

Available languages

3.5.6 Au to matic en gine cut-off
Ma chines are equipped with a safety en gine cut-off. The en gine
switches-off au to mat i cally if
• the oil pres sure is too low
• the film of lu bri ca tion oil is un sta ble as a re sult of
• ex ces sively high oil tem per a ture
• in cor rect baisc vis cos ity
• di lu tion of the oil by fuel or wa ter
• the lu bri cat ing oil fil ter is blocked
• a leak age in the oil re lief valve
• leak ages in pipes and seals
• the oil pumps and bear ings are worn
If the oil level is too low or the ma chine is tilted too
much, it can lead to an ad mix ture of air and thus to a
loss of vis cos ity.
Important
If the en gine cuts-out be cause the sup ply of lu bri cat ing oil is in -
suf fi cient, pro ceed as fol lows:
• Lo cate the fault and have it rec ti fied.
• Press the le ver few sec onds.
• Start the en gine.
3.5.7 Air fil ter main te nance in di ca tor
The en gines are equipped with a main te nance in di ca tor for air fil -
ters. In case of pol lu tion of the fil ter el e ment the rub ber bel low
con tracts by underpressure.
In this case, switch-off the en gine and clean or re place the air-fil -
ter.
B6599028.cdr
54
3. Op er a tion
B6599011.cdr

Advertisement

Table of Contents
loading

Table of Contents