User Manual LogEt 1/LogEt 1TH/LogEt 1Bio
Single-Use PDF Data Logger
Operations
01
Connect the data logger to computer. Configure parameters
and synchronize time via ElitechLog software. You can also use
the online configuration site to generate configuration filed
and drag it to removable storage disk "Elitech Log" to finish
configuration.
03
Double click
Double click the button quickly to mark the current time and
temperature.
05
Connect the logger to computer. Open the PDF report in removable storage disk
"Elitech Log" to view the data. You could also view data with ElitechLog
software.
Important!
Please read this User Manual carefully before your use data logger.
The data logger is ideal to monitor and record temperature(humidity) during storage and transportations for pharmaceuticals
and other products. It can be used widely in all parts of warehousing, logistics and cold chain.
System time may not be synchronized via online configuration site.
If Start Delay has set, logger will start recording after the delay time elapses.
In the following scenarios, logger can start recording without manual button pressing.
-If start mode set to Immediate Start, logger will start recording immediately after you remove it from the computer.
-If start mode set to Timing Start, logger will start recording automatically on your scheduled date and time.
You do NOT need to stop logger for data viewing. Just connect logger to computer and open the temporarily generated PDF
report in "Elitech Log" disk to view the data.
The logger will stop automatically when the recording points reach the setted point.
Please store the data logger under room temperature.
The humidity related parameter and description in the Manual is only for model LogEt 1TH.
The logger can NOT be re-configured once you start it.
The LCD screen will turn o automatically after 15 seconds of inactivity. Just single click the button can light on the screen.
After logger is started, the green LED light will blink once every 10 seconds. If alarm(s) are triggered, the red LED light will blink
once every 10 seconds (green LED will STOP blinks).
If battery indicator icon on LCD screen only display half of the icon, please do not use the logger for long-distance transport.
LogEt 1 series should avoid contact with unstable chemical solvents or other organic compounds especially should avoid for
long-term storage or exposed to environments that contain high concentrations of ketene, acetone, ethanol, isopropanol,
toluene and etc.
03
www.elitechlog.com
02
Press button
5 seconds
Press and hold the button for 5 seconds to start recording.
04
Press button
5 seconds
Press and hold the button for 5 seconds to stop recording.
Software download: www.elitechlog.com/softwares
www.elitechlog.com
Software download: www.elitechlog.com/softwares
04