B Fault Messages - Overview - Vaillant recoVAIR VAR 260/4 Installation And Maintenance Instructions Manual

Hide thumbs Also See for recoVAIR VAR 260/4:
Table of Contents

Advertisement

Appendix
Setting level
Nominal flow (VAR 260/4)
Nominal flow (VAR 360/4)
Exh. air nom. flow corr.
Sup. air nom. fl. corr.
Heat exchanger type
Frost prot. element
Air-earth collector
Pressure monitor
Step switch
Air quality sensor
U value
Contact data
Close the installation assistant?
1)
Fault lists are only available, and can only be deleted, if faults have occurred.
Fault messages – Overview
B
Message
F.800 Frost protection not
guaranteed
F.801 Frost protection not
guaranteed
F.802Fault: Ventilator exit air
F.803 Fault: Supply air ventil-
ator
F.804 Supply air temp. too
low
F.805 Air supply temp. of heat
exch. too high
F.806 Fault: Frost prot. ele-
ment
F.807 Failure: Sup. air diff.
pressure sensor
F.808 Failure: Exit air diff.
pressure sensor
F.809 Failure: Outside air
temp. sensor
F.810 Failure: Exit air temp.
sensor
F.811 Failure: Supply air
temp. sensor
20
Values
Unit
Min.
Max.
115
200
m³/h
175
280
m³/h
−40
40
%
−40
40
%
0
2
0,2
2,5
W/(m
Phone number
Possible cause
Outside temperature sensor
does not work/is defective
Exit-air temperature sensor
does not work/is defective
Heat exchanger protection is
active
Exhaust-air fan does not work/is
defective
Supply-air fan does not work/is
defective
Bypass does not work/is defect-
ive
Heat exchanger does not
work/is defective
The frost protection element
does not work/is defective
The frost protection element is
defective
Supply-air differential pressure
sensor does not work/is defect-
ive
Exit-air differential pressure
sensor does not work/is defect-
ive
Outside temperature sensor
does not work/is defective
Exit-air temperature sensor
does not work/is defective
Supply-air temperature sensor
does not work/is defective
Increment, select
5
5
1
1
Standard, Enthalpy
Not available, Electrical, Hydraulic
Not available, Available
Not available, Available
Not available, Available
1
2
0,1
K)
0 - 9
Yes, Back
Measure
Check that the outside temperature sensor works correctly.
Check that the exit-air temperature sensor works correctly.
Wait until the outside temperature increases (the product auto-
matically switches on no later than 60 minutes after the tem-
perature increases.).
Outside temperature: > −3 ℃
Check that the exhaust-air fan works correctly.
Check that the supply-air fan works correctly.
1.
Press the fault clearance key.
Fault clearance attempts: ≤ 3
2.
If you cannot eliminate the fault with the fault clearance at-
tempt, check that the bypass works correctly.
Check that the heat exchanger works correctly/has no leak-
ages.
Check that the frost protection element works correctly.
Replace the frost protection element.
Check that the supply-air differential pressure sensor works
correctly.
Check that the exit-air differential pressure sensor works cor-
rectly.
Check that the outside temperature sensor works correctly.
Check that the exit-air temperature sensor works correctly.
Check that the supply-air temperature sensor works correctly.
Installation and maintenance instructions recoVAIR 0020159949_07
Default
setting
0
0
Standard
Not avail-
able
Not avail-
able
Not avail-
able
Not avail-
able
0
1,5