Kaysun KFC-AY-2T-250D Owner's Manual

Wall-mounted fancoil type
Hide thumbs Also See for KFC-AY-2T-250D:

Advertisement

OWNER'S MANUAL
KFC-AY-2T-250D
KFC-AY-2T-250D1
KFC-AY-2T-250D2
Thank you very much for purchasing our air conditioner. Before using your
air conditioner, please read this manual carefully and keep it for future
reference.
Wall-mounted Fancoil Type
KFC-AY-2T-400D
KFC-AY-2T-400D1
KFC-AY-2T-400D2
KFC-AY-2T-600D
KFC-AY-2T-600D1
KFC-AY-2T-600D2

Advertisement

Table of Contents
loading

Summary of Contents for Kaysun KFC-AY-2T-250D

  • Page 1 OWNER'S MANUAL Wall-mounted Fancoil Type KFC-AY-2T-250D KFC-AY-2T-400D KFC-AY-2T-600D KFC-AY-2T-250D1 KFC-AY-2T-400D1 KFC-AY-2T-600D1 KFC-AY-2T-250D2 KFC-AY-2T-400D2 KFC-AY-2T-600D2 Thank you very much for purchasing our air conditioner. Before using your air conditioner, please read this manual carefully and keep it for future reference.
  • Page 2 Air inlet Air outlet Inlet pipe Return pipe Drain pipe Infrared signal Temperature receiver display Operation lamp Timer indicator Display panel Bottom plate Faceplate Display panel Horizontal air deflector Remote controller...
  • Page 3: Important Safety Information

    1. IMPORTANT SAFETY INFORMATION To prevent water leak, contact your dealer. When the system is installed and runs in a small room, it is required to keep the concentration of the water, if by any To prevent injury to the user or other people and property chance coming out, below the limit.
  • Page 4: Operation Range

    Failure to observe could cause the chemicals to become Open the faceplate, and you can find the temporary button on deposited in the unit, which could endanger the health of the display panel. (Refer to Fig 2-1) those who are hypersensitive to chemicals. This function is used to operate the unit temporarily in case you misplace the remote controller, or its batteries are exhausted.
  • Page 5: Adjusting Air Flow Direction

    Adjust vertical air Adjust the air flow louver properly and avoid direct air flow to Open the horizontal air deflector, and then manually adjust room inhabitants. vertical air deflector. Adjust the room temperature properly for a comfortable environment. Avoid excessive heating or cooling. C faceplate Prevent direct sunlight during cooling operation by using curtains or blinds.
  • Page 6: Maintenance Before A Long Stop Period

    Maintenance before a long stop period (eg. at the beginning of the cold season) S faceplate Drain the water system(for all heat exchangers). To avoid the risk of rupture due to freezing, it is advisable to drain the water from the system at the beginning of the cold season Maintenance before a long stop period (eg.
  • Page 7: Troubleshooting

    Symptom 3: White mist comes out of a unit Symptom 7: The outdoor unit fan does not spin. Symptom 3.1: Indoor unit During operation. The speed of the fan is controlled in order to optimize product operation. When humidity is high during cooling operation If the interior of an indoor unit is extremely contaminated, the temperature Table 7-1 distribution inside a room becomes uneven.
  • Page 8 Table 8-2 Symptoms Causes Solution Check whether the MODE When the automatic mode is indicated on the display is selected, the air conditioner will "AUTO" automatically change the fan The fan speed cannot be speed. changed. Protection against hot wind in Reduce the temperature of inlet in cooling mode.