Transformer; Fuse / Fuse Holder; Circuit Breaker - Vulcan-Hart CEF40 Service Manual

Table of Contents

Advertisement

CEF40/75 FRYER - REMOVAL AND REPLACEMENT OF PARTS
Leave 1/8" exposed wire showing at
contactor power terminal connections (Fig. 23) to
prevent capture of wire insulation. Capture of
insulation at power connections can lead to
overheating and premature failure.
Fig. 23
4.
Reverse procedure to install.

TRANSFORMER

electrical power to the machine and
follow lockout / tagout procedures.
1.
Remove ELECTRICAL COVER .
NOTE: Document wire connections.
2.
Disconnect wires from transformer (Fig. 24).
Fig. 24
3.
Remove screws and trasformer.
4.
Reverse procedure to install.
F45657 (0517)
Disconnect the
Page 12 of 25

FUSE / FUSE HOLDER

electrical power to the machine and
follow lockout / tagout procedures.
1.
Replace fuse:
A.
Remove fuse access cover.
B.
Remove fuse cap and fuse.
Fig. 25
C.
Reverse procedure to install.
2.
Replace fuse holder:
A.
Remove ELECTRICAL COVER .
NOTE: Document wire connections.
B.
Disconnect wires from fuse holder.
C.
Remove screws, nuts, and fuse holder.
D.
Reverse procedure to install.

CIRCUIT BREAKER

electrical power to the machine and
follow lockout / tagout procedures.
NOTE: Only CEF75 fryers have circuit breakers.
1.
Remove ELECTRICAL COVER .
NOTE: Document wire connections.
2.
Disconnect wires from circuit breaker (Fig. 26).
Disconnect the
Disconnect the