Error Codes and troubleshooting
When the error occurs and remains, the Error messages
is displayed in Red.
Type of
error
By pushing the knob button, the Error code number is
displayed.
During error, new welding sequence is blocked until the
reason of error remains.
Table 1 Error codes
Error code
Symptoms
The machine has shut
36
down because it has
overheated.
The machine has shut
37
down because it has
overheated.
266
Torch is too warm.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
English
When the error vanished, it is now possible to
acknowledge the error by pushing the knob. The
background error message becomes white
Table 2 shows list of basic errors that can appear. To get
full list of error codes, please contact Lincoln Electric
service.
Error
code
Cause
System detected a temperature
level beyond the normal system
operating limit.
System detected a temperature
level beyond the normal system
operating limit.
No liquid flows in water torch
WARNING
23
Recommended Course of Action
Be sure process does not exceed duty
cycle limit of the machine.
Check the setup for proper air flow around
and through the system.
Check that the system has been properly
maintained,
including
accumulated dust and dirt from the intake
and outlet louvers.
User interface show information when
machine will be cooled down. To continue
welding operation Please press left knob
or start welding operation by the torch
trigger
Be sure process does not exceed duty
cycle limit of the machine.
Check the setup for proper air flow around
and through the system.
Check that the system has been properly
maintained,
including
accumulated dust and dirt from the intake
and outlet louvers.
Check the cooling liquid level, and fill
liquid if the level is too low.
Check proper connection of cooling
circuit
"Done",