7.4.2
WIRING THE MAIN DISTRIBUTION FRAME USING CABLE HG4302B
On main distribution frame side, this cable incorporates:
♦
two yellow strips (8 Tx/Rx)
♦
one red strip (DECT synchronization)
Connecting S0 and/or DECT
RJ45
S0 / DECT
5
4
6
0 1
0 2
0 3
ED0
NED0
RD0
0G
(A02)
(A03)
(C02)
GRAY
WHITE
TRANSPARENT
ED4
NED4
RD4
1G
(B08)
(B09)
(C09)
GRAY
BLUE
TRANSPARENT
YELLOW
SYNP
SYNN
SYNAP
SYNAN
4G
(A03)
(A02)
(C09)
RED
BLUE
RED
DECT V11 CLOCKS: strip 4G
The cable is used to connect the DECT 800 ms clock signal. This clock is output to three
V11 differential pairs (see LDS interfaces). Any V11 DECT clock connection must be set up
on strip 4G.
♦
incoming DECT clock (slave card) / outgoing clock (master card): SYNP (polarity
+), SYNN (polarity -)
♦
outgoing DECT clock A: SYNAP (+), SYNAN (-)
♦
outgoing DECT clock B: SYNBP (+), SYNBN (-)
WIRING The BADX PLUG HR5124B
Set the female connector to the CFX position
From
B13
B10
B11
B12B
C15
A25
B16
B26
7.4.3
PLDS CARD AND REMOTE POWER SUPPLY CABLE
This equipment is the same as for the F2 range. See the section concerned.
PAGE
92/171
This confidential document is the property of MATRA NORTEL COMMUNICATIONS and may not be copied or circulated without permission.
Ce document confidentiel est la propriété de MATRA NORTEL COMMUNICATIONS et ne doit pas être reproduit ou communiqué sans autorisation.
3
0 4
0 5
0 6
NRD0
ED1
NED1
RD1
(C03)
(B03)
(B04)
(C04)
BLUE
GRAY
YELLOW
TRANSPARENT
NRD4
ED5
NED5
RD5
(C10)
(B10)
(B11)
(C11)
GRAY
BROWN
TRANSPARENT
SYNBP
SYNBN
(C04)
(C03)
(C02)
BLUE
RED
BLUE
To
C12
CL2
C09
CL4
A11
CL8
A13
DEBTRAM
C22
TRANSMIT0
A22
RECEPT0
C20
TRANSMIT1
A20
RECEPT1
0 7
0 9
0 8
1 0
1 1
NRD1
ED2
NED2
RD2
(A04)
(B05)
(B06)
(C05)
BROWN
GRAY
BLACK
TRANSPARENT
NRD5
ED6
NED6
RD6
(C12)
(A09)
(A10)
(A11)
BLACK
GRAY
RED
TRANSPARENT
Signal
1 2
1 3
1 4
NRD2
ED3
NED3
RD3
(C06)
(A06)
(A07)
(C07)
RED
GRAY
GREEN
TRANSPARENT
NRD6
ED7
NED7
RD7
(A12)
(A13)
(A14)
(C13)
GREEN
ORANGE
WHITE
PURPLE
Qty Item 3
8
LCAH-30521-001-05=01/EN
1 5
1 6
NRD3
(C08)
WHITE
NRD7
(C14)
BLUE
SHIELD
(B01)
Need help?
Do you have a question about the MC 6500 and is the answer not in the manual?