On the main distribution frame, configure radio base station 1 as "master".
Connect radio base station 2 as "slave" to strip J4 (pins 1 to 4).
There are two methods of connecting the two synchro wires for the "slave" radio base
station:
1. either directly to strip J6 (pins 1 and 2) on the ROCZB card
2. or to strip J5 (pins 1 and 2) on the ROCYE card; in this case connect pins 1 and 2
of strip J5 (ROCYE card) and strip J6 (ROCZB card).
Note:
The second solution (see Figure 12) is not mandatory. However, it will facilitate
the installation of a third base station.