For MC 6501-L PBX release 11.3 (with 2-channel base stations)
The MC 6501-L PBX must be fitted with the OCT3 CPU card and ADS200 power supply.
A 40 V or 48 V power supply can be used. However, you are recommended to use the 48 V
supply on the faceplate of the ADS200 power supply unit.
♦
LS1 card, reference HJ3924AC or earlier
♦
maximum number of radio base stations: 16
For MC 6501-R PBX (with 2-channel base stations)
Two options are available:
1) ADS150 power supply, reference HR5102AJ or earlier:
♦
48 V power supply not available on the faceplate
♦
40 V remote power supply
♦
maximum number of radio base stations: 10
You can also use the radio base station local power supply. See note about locally-powered
radio base station at the end of section 2.2.3.
You are recommended to upgrade by standard exchange.
2) Power supplies ADS150 or HR5102AK and later:
♦
a 48 V remote power supply is available on the faceplate
♦
LS1 cards (reference HJ3924AC maximum)
♦
maximum number of radio base stations: 10