6 Capacity Tables

6.1 Cooling Capacity Table
Table 6.1: Ceiling & floor cooling capacity
Outdoor air
Capacity
temperature
(kW)
(°C DB)
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
3.6
27.0
29.0
31.0
33.0
35.0
37.0
39.0
42.0
44.0
46.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
4.5
27.0
29.0
31.0
33.0
35.0
37.0
39.0
42.0
44.0
46.0
Abbreviations:
TC: Total capacity
SC: Sensible capacity
Notes:
1.
Shaded cells indicate rating condition.
8
14/20
16/23
TC
SC
TC
SC
kW
kW
kW
kW
2.5
1.9
2.9
2.1
2.5
1.9
2.9
2.1
2.5
1.9
2.9
2.1
2.5
1.9
2.9
2.1
2.5
1.9
2.9
2.1
2.5
1.9
2.9
2.1
2.5
1.9
2.9
2.1
2.5
1.9
2.9
2.1
2.5
1.9
2.9
2.1
2.5
1.9
2.9
2.1
2.5
1.9
2.9
2.1
2.5
1.9
2.9
2.1
2.5
1.9
2.9
2.1
2.5
1.9
2.9
2.1
2.5
1.9
2.9
2.1
2.5
1.9
2.9
2.1
2.5
1.9
2.9
2.1
2.5
1.9
2.9
2.1
2.5
1.9
2.9
2.1
3.1
2.4
3.7
2.6
3.1
2.4
3.7
2.6
3.1
2.4
3.7
2.6
3.1
2.4
3.7
2.6
3.1
2.4
3.7
2.6
3.1
2.4
3.7
2.6
3.1
2.4
3.7
2.6
3.1
2.4
3.7
2.6
3.1
2.4
3.7
2.6
3.1
2.4
3.7
2.6
3.1
2.4
3.7
2.6
3.1
2.4
3.7
2.6
3.1
2.4
3.7
2.6
3.1
2.4
3.7
2.6
3.1
2.4
3.7
2.6
3.1
2.4
3.7
2.6
3.1
2.4
3.7
2.6
3.1
2.4
3.7
2.6
3.1
2.4
3.7
2.6
Indoor air temperature (°C WB/DB)
18/26
19/27
TC
SC
TC
SC
kW
kW
kW
kW
3.4
2.3
3.6
2.4
3.4
2.3
3.6
2.4
3.4
2.3
3.6
2.4
3.4
2.3
3.6
2.4
3.4
2.3
3.6
2.4
3.4
2.3
3.6
2.4
3.4
2.3
3.6
2.4
3.4
2.3
3.6
2.4
3.4
2.3
3.6
2.4
3.4
2.3
3.6
2.4
3.4
2.3
3.6
2.4
3.4
2.3
3.6
2.4
3.4
2.3
3.6
2.4
3.4
2.3
3.6
2.4
3.4
2.3
3.6
2.4
3.4
2.3
3.6
2.4
3.4
2.3
3.6
2.4
3.4
2.3
3.6
2.4
3.4
2.3
3.6
2.4
4.2
2.8
4.5
2.9
4.2
2.8
4.5
2.9
4.2
2.8
4.5
2.9
4.2
2.8
4.5
2.9
4.2
2.8
4.5
2.9
4.2
2.8
4.5
2.9
4.2
2.8
4.5
2.9
4.2
2.8
4.5
2.9
4.2
2.8
4.5
2.9
4.2
2.8
4.5
2.9
4.2
2.8
4.5
2.9
4.2
2.8
4.5
2.9
4.2
2.8
4.5
2.9
4.2
2.8
4.5
2.9
4.2
2.8
4.5
2.9
4.2
2.8
4.5
2.9
4.2
2.8
4.5
2.9
4.2
2.8
4.5
2.9
4.2
2.8
4.5
2.9
20/28
22/30
TC
SC
TC
SC
kW
kW
kW
kW
3.8
2.5
4.3
2.4
3.8
2.5
4.3
2.4
3.8
2.5
4.3
2.4
3.8
2.5
4.3
2.4
3.8
2.5
4.3
2.4
3.8
2.5
4.3
2.4
3.8
2.5
4.3
2.4
3.8
2.5
4.1
2.3
3.8
2.5
4.1
2.3
3.8
2.5
4.0
2.2
3.8
2.5
4.0
2.2
3.8
2.5
4.2
2.6
3.8
2.5
4.2
2.6
3.8
2.5
4.2
2.6
3.7
2.4
3.8
2.3
3.7
2.4
3.8
2.3
3.7
2.4
3.8
2.3
3.7
2.4
3.8
2.3
3.7
2.4
3.8
2.3
4.8
3.0
5.3
3.4
4.8
3.0
5.3
3.4
4.8
3.0
5.3
3.4
4.8
3.0
5.3
3.4
4.8
3.0
5.3
3.4
4.8
3.0
5.3
3.4
4.8
3.0
5.3
3.4
4.8
3.0
5.3
3.4
4.8
3.0
5.2
3.0
4.8
3.0
5.1
3.0
4.8
3.0
5.1
2.9
4.8
3.0
5.0
2.9
4.8
3.0
4.9
2.8
4.8
3.0
4.8
2.8
4.8
3.0
4.8
2.9
4.6
2.8
4.7
2.8
4.6
2.8
4.7
2.8
4.6
2.8
4.7
2.8
4.6
2.8
4.7
3.1
Table continued on next page ...
24/32
TC
SC
kW
kW
4.7
2.5
4.7
2.5
4.6
2.4
4.5
2.4
4.5
2.4
4.4
2.3
4.4
2.3
4.3
2.2
4.2
2.2
4.2
2.2
4.1
2.2
4.1
2.2
3.9
2.1
3.9
2.1
3.9
2.1
3.8
2.1
3.8
2.1
3.8
2.1
3.8
2.1
5.9
3.0
5.9
3.0
5.8
3.0
5.6
2.9
5.7
3.0
5.7
3.0
5.6
3.0
5.5
3.0
5.4
2.9
5.2
2.8
5.2
2.8
5.1
2.7
5.1
2.7
5.0
2.7
4.9
2.6
4.8
2.6
4.8
2.6
4.8
2.6
4.8
2.6
201805

Advertisement

Table of Contents
loading

Table of Contents