PRODUCT DESCRIPTION The transmitter TRA-102ND-E with 4-20 mA outputs is designed to measure air temperature and relative humidity in chemically non- aggressive environments. The transmitter communicates by two galvanically separated current loop 4-20mA. Each loop has two-wire connection and each loop requires power from evaluation device.
WARNING Don´t use and don’t store the device without a sensor cover. Don´t connect transmitter while power supply voltage is on. The cables should be located as far as possible from potential interference sources. Installation, commissioning and maintenance may only be carried out by personnel with qualification by applicable regulations and standards.
Page 4
Response time: t90 < 7 min (temperature step 20 ºC) Relative humidity: Accuracy: ±3.0 %RH from 5 to 95 %RH at 23 °C Measuring range: 0 to 100 %RH Resolution: 0.1 %RH Response time: t90 < 30 s (humidity step 65 %RH, constant temperature) GENERAL Power supply voltage:...
OPERATING CONDITIONS Temperature operating range: -30 to +80 ºC Relative humidity operating range: 0 to 100 %RH CALCULATION OF THE MEASURED VALUES T[°C] = 6.875 x I[mA] – 57,5 Temperature: Relative humidity: RH[%RH] = 6.25 x I[mA] - 25 END OF OPERATION Disconnect the device and dispose it according to current legislation for dealing with electronic equipment.
Need help?
Do you have a question about the TRA-102ND-E and is the answer not in the manual?
Questions and answers