Summary of Contents for SDMO KOHLER PERFORM 3000 TB UK C5
Page 1
Manuel d'utilisation et d’entretien (Notice originale) Instruction and maintenance manual (Translation of the original note) PERFORM 3000 TB UK C5 4500 TB UK C5 6500 TB UK C5 33522200901_2_1 07/2021...
Page 5
CONTENTS Section 1. Preface Section 6. Transporting and storing the generating set Section 2. Instructions and safety regulations (personal protection) Section 7. Repairing minor faults Section 3. Getting started with the generating set Section 8. Technical specifications Section 4. Using the generator set Section 9.
Page 6
Risks relating to exhaust gases DANGER RISK OF POISONING DANGER OF DEATH (if appropriate) The carbon monoxide present in the exhaust gas may lead to death by inhalation if the concentration levels in the atmosphere are too high. Always use the unit in a well ventilated area where the gases cannot accumulate. For safety reasons and for correct operation of the unit, correct ventilation is essential (risk of poisoning, engine overheating and accidents involving, or damage to, the surrounding equipment and property).
Page 7
2.7.4 Connection and choice of cables For all connections, use flexible, strong rubber-sheathed cables which comply with standard IEC 60245-4 or equivalent cables, and ensure that these are kept in perfect condition. Only use one item of class I electrical equipment per socket and connect up equipment using a cable equipped with a PE protective conductor (green/yellow);...
Page 8
Section 3. Getting started with the generating set Key to illustrations The The cover illustrations can be used to identify the various components of the unit. The procedures in the manual refer to these illustrations using letters and numbers as identifiers: "A1" refers to the number 1 on figure A. Earth terminal Choke Air filter cover fasteners...
Page 9
Check the generating set is in a good general condition (bolts, hoses) Inspect the entire unit before start-up and after each use to prevent any faults or damage. Check that the unit is clean, in particular the air intake zones (engine air intake, air vents, air filter, etc.). Check all of the unit's pipes and hoses to ensure they are in good condition and that there are no leaks.
Page 10
Maintenance intervals table The maintenance frequency is given as an indication only and is for devices using fuel and oil complying with the specifications given in this manual. The maintenance intervals can be shortened depending on the unit's operating conditions and requirements. Perform the maintenance operations at the indicated due dates even if the number of hours' operation has not been reached.
Page 11
5.3.4 Clean or replace the air filter IMPORTANT Risk of fire or explosion: for a foam element, only use soapy water and clean engine oil during this operation. If the filter elements are excessively dirty or damaged (torn, pierced), it is essential to replace them with new elements and at least every 3 cleaning procedures.
Page 12
Storage conditions This procedure for storing the unit or protecting it over the winter must be respected if it is not used for a period of up to 1 year. For longer periods of storage, it is recommended to contact your nearest agent or to start up the unit for a few hours every year, ensuring that the storage procedure is respected afterwards.
Page 13
Section 8. Technical specifications Operating conditions The stated outputs of the units are obtained under the reference conditions outlined in ISO 8528-1(2005): Total barometric pressure: 100 kPa - Ambient air temperature: 25°C (298 K) - Relative humidity: 30%. The unit's output is reduced by approximately 4% for every additional 10°C and/or approximately 1% for every additional 100m in altitude.
Page 14
(less than once a month), use new fuel with each use or add a stabilizing additive to the fuel tank. EC Declaration of conformity We, SDMO Industries - 270 rue de Kerervern, 29490 GUIPAVAS/CS 40047, 29801 BREST CEDEX 9 – France, hereby declare under our sole responsibility that the following generating sets:...
Page 15
Guaranteed sound power level (LwA) : 96 dBA, 97 dBA Genset rated power (Max power) : 2,4 kW, 3,2 kW, 5,2 kW Signed for and on behalf of the above-named manufacturer: Issue in Brest on 7/2/2021 Name:L. ANDRIEUX Function:Président, SDMO Industries 1144_EN.docx 23/26 2021-07-02...
Page 16
SDMO Industries; normal wear and tear of the unit or of one of its components; damage due to negligence, failure to monitor, service or clean the unit;...
Page 17
SDMO Industries is liable for any conformity issues with your unit under the conditions set out in article L. 211-4 and following of the Consumer Code and for hidden defects in the sold item under the conditions set out in articles 1641 and following of the civil code.
Need help?
Do you have a question about the KOHLER PERFORM 3000 TB UK C5 and is the answer not in the manual?
Questions and answers