Download Print this page

RS Automation AnyTouch V7 Plus Series Operating Instructions Manual

Hide thumbs Also See for AnyTouch V7 Plus Series:

Advertisement

Quick Links

Make sure that the delivered unit conforms to your requirement, and also check for any missing or damaged parts.
Before using this V706+, be sure to read this OPERATING INSTRUCTIONS thoroughly to ensure proper operation.
[Accessories] V706+ OPERATING INSTRUCTIONS: 1 copy, Fixtures: 4 pcs
[Models]
5.7 inch display
Device type
T
: TFT color LCD (QVGA, 32,768 colors)
C
: STN color LCD (QVGA, 32,768 colors)
M
: STN color LCD (QVGA, monochrome 8-grade)
Notes on Safe Usage
In this "V706+ OPERATING INSTRUCTIONS", you will find various notes categorized under the following two levels with the
signal words "Danger" and "Caution."
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious
injury.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate
injury and could cause property damage.
Even some items indicated
Never use the output function of AnyTouch for operations that may threaten human life or to damage the system,
such as switches to be used in case of emergency. Please design the system so that it can cope with malfunction of
a touch switch. A malfunction of the touch switch will result in machine accident or damage.
Turn off the power supply when you set up the unit, connect cables or perform maintenance and inspection.
Otherwise, electrical shock or damage may occur.
Never touch any terminals while the power is on. Otherwise, electric shock may occur.
You must put a cover on the terminals on the unit when you turn the power on and operate the unit. Without the
terminal cover in place, an electric shock may occur.
The liquid crystal in the LCD panel is a hazardous substance. If the LCD panel is damaged, never swallow the leaked
liquid crystal. If the liquid crystal spills on your skin or clothing, use soap and wash off thoroughly.
For AnyTouch using a lithium battery, never disassemble, recharge, deform by pressure, short-circuit, nor reverse the
polarity of the battery, and never dispose of the battery in fire. Failure to follow these conditions will lead to explosion
or ignition.
For AnyTouch using a lithium battery, never use a battery that is deformed, leaks, or shows any other signs of
abnormality. Failure to follow these conditions will lead to explosion or ignition.
Check the appearance of the unit when it is unpacked. Do not use the unit if any damage or deformation is found.
Failure to do so may lead to fire, damage or malfunction.
For use in a facility or for a system related to nuclear energy, aerospace, medical, traffic equipment, or mobile
installations, please consult your local distributor.
Operate (or store) AnyTouch under the conditions indicated in this manual and related manuals. Failure to do so
could cause fire, malfunction, physical damage or deterioration.
Understand the following environmental limits for use and storage of AnyTouch. Otherwise, fire or damage to the unit
may result.
- Avoid locations where there is a possibility that water, corrosive gas, flammable gas, solvents, grinding fluids or
cutting oil can come into contact with the unit.
- Avoid high temperature, high humidity, and outside weather conditions, such as wind, rain or direct sunlight.
- Avoid locations where excessive dust, salt, and metallic particles are present.
- Avoid installing the unit in a location where vibration or physical shock may be transmitted.
V7 Plus Series
V706+ OPERATING INSTRUCTIONS
may also result in a serious accident.
Power supply type
D
: 24V DC (Comply with CE/UL/cUL)
Touch switch type
M
: matrix resistance film type
(None)
: analog resistance film type
1
3333NK0

Advertisement

loading
Need help?

Need help?

Do you have a question about the AnyTouch V7 Plus Series and is the answer not in the manual?

Questions and answers

Summary of Contents for RS Automation AnyTouch V7 Plus Series

  • Page 1 3333NK0 V7 Plus Series V706+ OPERATING INSTRUCTIONS Make sure that the delivered unit conforms to your requirement, and also check for any missing or damaged parts. Before using this V706+, be sure to read this OPERATING INSTRUCTIONS thoroughly to ensure proper operation. [Accessories] V706+ OPERATING INSTRUCTIONS: 1 copy, Fixtures: 4 pcs [Models] 5.7 inch display...
  • Page 2 fire, malfunction, or trouble. Do not attempt to repair, disassemble or modify AnyTouch at your site. Ask RS Automation Co., Ltd. or the designated contractor for repair. Otherwise, it may cause a malfunction.
  • Page 3 Specifications Item Specifications Rated Voltage 24V DC 24V DC Permissible Range of Voltage Permissible Momentary within 1ms Power Failure 16W or less Demand (maximum rating) Rushed Electric Current 20A or less (with a rise time 0.1ms) With-stand voltage DC external terminals to FG: 500V AC per minute Insulation Resistance 500V DC, 10M or more...
  • Page 4 Names of Components and Dimensions Dimensions (unit : mm) 182.5 173.6 42.5 6. 7. 8. 9. 1. Display 8. USB-B (slave port) 2. Power lamp (POWER) * 9. USB-A (master port) 3. Function switches 10. Power supply terminal block 4. Option unit connector (CN1) 11.
  • Page 5 Modular Jack (MJ2) This port is used for PLC connection. And it is also used for such connection as data transfer, temperature controller network, bar code reader, CREC, and V-I/O, etc. when using the optional unit, 'DU-01'. The pin arrangement of modular jack is as follows: Pin No.
  • Page 6 Setting of DIP Switches Setting of dip switches is as follows. (The following figure shows the condition when the panel is unpacked.) When setting DIP switch, turn the power off. MJ1 (modular jack 1) send/receive signal terminating resistor MJ2 (modular jack 2) send signal terminating resistor MJ2 (modular jack 2) receive signal terminating resistor CF auto load 1 2 3 4...
  • Page 7 Electrical Wiring Electric shock hazards Shut the power off before connecting the power supply cable. Power Supply Cable Connection Connect the power suppy cable to the terminal on the backside of the unit. Grounding Power supply 24V DC When connecting the power supply cable, tighten the terminal screw to the following torque. Screw Size Torque Clamp Terminal (Unit: mm)
  • Page 8 CURRENT : 0.6A CE mark Serial number Ser No. : 3080058 a CE Mark: RS Automation Co., Ltd. Made in Japan The V706 Plus series complies with EMC directive: EN55011 Class A, EN61000-6-2. UL/cUL Mark: The V706 Plus series is UL/cUL-approved.
  • Page 9 3333NK0 V7 Plus시리즈 V706+ 사용설명서 AnyTouch V706 Plus 시리즈를 구입하여 주셔서 대단히 감사합니다. 먼저 희망하신 상품이 틀림없는지 확인해 주십시오. 올바른 조작을 위해 V706+을 사용하기 전에 본 사용 설명서를 읽으십시오. [부속품] 사용설명서(본서) 1부, 설치금구 4개 [형식] 5.7 인치 디스플레이 전원 공급 유형 24V DC (CE/UL/cUL 준수) 기기...
  • Page 10 ○포장 개봉시에는 외관 체크를 실시해 주십시오. 손상, 변형이 있는 것은 사용하지 마십시오. 화재, 오작동, 고장의 원인 이 됩니다. ○원자력 관련, 항공우주 관련, 의료 관련, 교통기기 관련, 승용이동체 관련 또는 이들 시스템의 특수용도로 사용하는 경우 에는 당사 영업부에 상담해 주십시오. ○AnyTouch는 본서 및 관련 매뉴얼 기재의 일반사양 환경에서 사용(보관)해 주십시오. 일반사양 이외의 환경에서 사용하 면...
  • Page 11 일반사양 항목 사양 DC 24V 정격전압 DC 24V±10% 전압허용범위 전 1ms 이내 허용순간정전시간 원 16W 이하 소비전력(최대 정격) 20A 이하(기동시간 0.1ms 일때) 돌입전류 DC 외부단자와 FG간: AC500V, 1분간 내전압 DC500V, 10MΩ 이상 절연저항 0℃~+50℃ * 작동주위온도 물 리 -10℃~+60℃ 보존주위온도 적...
  • Page 12 각부 명칭 및 치수 단위: mm 182.5 173.6 42.5 6. 7. 8. 9. 1. 디스플레이 8. USB-B(슬레이브 포트) 2. POWER 램프(POWER) * 9. USB-A(마스터 포트) 3. 펑션스위치 10. 전원입력 단자대 4. 옵션 유닛용 커넥터(CN1) 11. 설치구멍 5. 전지 홀더 12. 딥스위치 6.
  • Page 13 모듈러 잭(MJ2) PLC와의 통신에 사용합니다. 또, 옵션 카세트 「DU-01」 장착시에는 온도조절기, 바코드 리더, CREC, V-I/O 등을 접속할 수 있습니다. 모듈러 잭의 핀 배치는 아래와 같습니다. 핀 No. 신호명 내용 슬라이더 스위치 +SD/RD RS-485 데이터(+) 상 RS-422 송신데이터(+) 하 SD/RD RS-485 데이터( 상...
  • Page 14 딥스위치 딥스위치의 설정은 아래와 같습니다. (아래 그림: 공장출하시 상태) 딥스위치를 설정할 때는 본체 전원을 OFF로 한 후에 실시해 주십시오. MJ1(모듈러 잭1) 송수신 신호의 종단저항 MJ2(모듈러 잭2) 송신 신호의 종단저항 MJ2(모듈러 잭2) 수신 신호의 종단저항 CF 자동로드 1 2 3 4 (확대도) ○DIPSW1, 2, 3 (종단저항...
  • Page 15 전원케이블 배선과 접지에 대하여 감전의 우려가 있습니다. 전원케이블의 배선은 전원 OFF 상태에서 실시해 주십시오. 전원케이블 배선 ○전원케이블은 본체 배면의 단자에 접속합니다. 접지 전원 DC24V ±10% ○전원을 배선하는 경우의 단자나사 조이기는 아래 값으로 실시해 주십시오. 압착단자(단위: mm) 나사 사이즈 조임토크 M3.5 0.5 N m 7.1 MAX 7.1 MAX...
  • Page 16 INPUT : 24VDC CURRENT : 0.6A 전류 CE 마크 시리얼 No. Ser No. : 3080058 a RS Automation Co., Ltd. Made in Japan CE 마킹에 대하여 V706 Plus 시리즈는 EMC 지령에 적합한 제품입니다. EN55011 Class A, EN61000-6-2에 적합합니다. UL/cUL 마크에 대하여...
  • Page 18 Publication AnyTouchV7-IN001A-V706-EK - November 2010...
  • Page 20 Copyright © 2010 RS Automation Co., Ltd. All rights reserved.