VENT FrEE / FluElEss Gas FirEplacE iNsTallaTioN & opEraTiNG InstructIon Manual Please read these instructions carefully before installation, use and retain them for future reference Natural Gas VFSL1200-N These appliances conform to the requirements of SANS 1539:2017 LPGSA Permit Number: 1013-49/1-RSA-17-A...
Page 2
CONGRATULATIONS o n y o u r p u r c h a s e o f a CHAD-O-CHEF FirEplACE W E L C O M E a n d t o t h e CHAD-O-CHEF family...
GENERAL INSTRUCTIONS AND SAFETY NOTES Thank you for purchasing your new CHAD-O-CHEF Gas Fireplace manufactured to high standards and tested for compliance with SANS 1539:2017 The manufacturer and /or its agents and distributors will not be held responsible for injuries or damages caused by faulty or incorrect installation or use of the appliance.
Min Room size without permanent ventilation 119m³ INSTALLATION REQUIREMENTS Your VFSL1200-N Fireplace is designed to drop into a hole prepared in a masonry construction. In order to function correctly the unit needs adequate ventilation holes to be cut into the masonry construction housing the unit ( 2x brick-sized holes ).
INSTALLATION INSTRUCTIONS FOR QUALIFIED GAS INSTALLER A masonry shelf may be fitted 800mm above the fireplace but under no circumstances should any electrical equipment such as a TV be positioned above. Any ornaments positioned above the fireplace must be able to withstand the elevated temperatures and moisture.
NG6801 VALVE: OPERATING INSTRUCTIONS The ODS pilot is situated on the side of the burner. The gas control valve is accessible by removing the side cover, which lifts off. 1. Push in and turn the control knob to the pilot position and hold it there for a few seconds to allow the gas to feed to the pilot.
Jet is centrally aligned with the burner venturi. Check for spider webs in the venturi. The Glass pebbles supplied with Chad-O-Chef fireplaces must be inside the burner. Ensure that the right amount of glass pebbles placed on the fireplace are correct, as supplied by Chad-O-Chef.
WARNINGS WARNING This appliance shall not be installed in bedrooms or bathrooms. WARNING This is an un-vented gas heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate ventilation must be provided. Refer to appropraite section of the user manual. WARNING CARBON MONOXIDE POISONING CAN LEAD TO DEATH...
CLEANING Should soot deposits appear on the stainless steel, first clean with a dry cloth when cold, and follow up with a cloth dampened with methylated spirits and a final buffing with a dry cloth. Do not use an oil based cleaner, as the oil tends to discolour the stainless steel when heated.
Guarantee Claim Form The Guarantee given by Chad-O-Engineering (Pty) Ltd covers the working components, on all Chad-O-Chef Gas Fireplaces for the period of 2 Years (+ 1 Year t’s & c’s apply), covering manufacturing defects caused in the manufacturing process. This does not cover component malfunction if the product is not installed by a registered Gas Installer, or the product is modified after leaving the factory.